Publish your products
Model 5450A COLLECTanDRAIN - Auxiliary Drain

Model 5450A COLLECTanDRAIN - Auxiliary Drain

COLLECTanDRAIN Model 5450 Self-Maintaining Auxiliary Drain

The COLLECTanDRAIN® Model 5450 Series of auxiliary drains feature a traditionally configured condensation collection assembly contained inside an insulated and heated cabinet. By incorporating a unique, self-maintaining design the Model 5450 offers more than just freeze protection. This feature prevents the auxiliary drain from filling beyond the safety level of the heated cabinet and automatically sheds condensation from the collection assembly when the level reaches approximately 80%. Any additional accumulation will flow into a drain trap that allows the excess to automatically drain from the system while maintaining the integrity of the dry valve. The easily mounted, lockable, steel cabinet is finished in a highly-visible, red, powder coat that includes appropriate identification signage and can be wired to the fire panel for remote notification. The Model 5450 is designed for installation in climates where freezing or below freezing temperatures are present and result in the failure of typical collectors. The Model 5450 maintains a comfortable temperature above freezing while minimizing power consumption. Available with galvanized or black steel and an optional Hot Operation Trouble (HOT) Monitor.

Model 5450A has galvanized piping and model 5450B includes black steel piping.

Model 5450H includes the hot operation trouble (HOT) monitor to send notifications if there is a heater issue. The Hot Operation Trouble (HOT) monitor tracks the heater's on/off cycles and compares that information against its own internal thermostat to make sure the heater is performing correctly. For example, if the cabinet door is accidentally left open causing the heater to run continuously, the HOT monitor will trip the local audible and visual alarms and alert the fire control panel. It will also trigger a notification if it detects that the heater is not operating enough to keep the interior temperature safely above freezing.

Specification
  • Model 5450 COLLECTANDRAIN

    2.1 DRY-PIPE SYSTEM AUXILIARY DRAIN

    Auxiliary Drain and Condensation Collecting Assemblies for Dry Pipe and Preaction Sprinkler Systems shall be installed in order to provide for complete system drainage. Where the trapped capacity of an isolated section of system piping exceeds 5 gallons an auxiliary drain shall be provided. The auxiliary drain shall be installed in an accessible location and be capable of collecting and removing moisture from the system while minimizing the potential for excessive loss of air pressure and possible unplanned operation of the dry pipe valve. The Auxiliary Drains shall meet the following requirements:

    1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the work include, but are not limited to, the following:
      1. AGF Manufacturing Inc.; Model 5450 COLLECTANDRAIN™.
      2. <Insert manufacturer's name>.
    2. Standards:
      1. NFPA 13.
      2. NFPA 25.
    3. Components:
      1. Cabinet: A secure locking, red powder-coated, insulated cabinet with required signage adhering to NFPA guidelines.
      2. Heating Element: Temperature-sensitive internal heating element to prevent excess condensation in the drum drip from freezing.
      3. Float Switch: Activates an audible alarm and visual signal to notify when the auxiliary drain requires maintenance.
      4. System Alarm Test Button: An integral TEST button allows for system testing.
      5. Thermometer: Externally mounted for easy monitoring of temperature conditions inside the cabinet.
      6. Drain Assembly:
        1. Two 1 inch by 2 inches (25 mm by 51 mm) Bell Reducers.
        2. 2 inch by 12 inches long (51 mm by 305 mm) Condensate Nipple.
        3. 1 inch (25 mm) Galvanized Square Head Plug.
        4. Two 1 inch (25 mm) MIPT x FIPT Brass quarter-turn ball valves with chrome-plated balls.
        5. Ancillary drain with Y strainer to shed accumulated water when the auxiliary drain reaches approximately 80% full.
        6. Mounting hardware.
        7. Each unit is fully assembled and ready to be attached to dry pipe systems using galvanized or black piping components and 1-inch brass quarter-turn ball valves with chrome-plated brass balls.
  • 4. Product: Model 5450A. Cabinet with Galvanized Auxiliary Drain, Heater, and Ancillary Drain.
  • 5. Product: Model 5450B. Cabinet with Black Steel Pipe Auxiliary Drain, Heater, and Ancillary Drain.
  • 6. Product: Model 5450H. Cabinet with Galvanized Auxiliary Drain, Heater, Ancillary Drain, and Hot Operation Trouble Monitor.
  • 7. Product: Model 5680A. All-Weather Cover for Exposed Locations.
Technical specification
  • Unique ref.agf-model-5450
  • Product familyAGF Fire Sprinkler Products
  • Product groupCOLLECTanDRAIN
  • TypeObject (single object)
  • Date of publishing2022-03-03
  • Edition number1
  • Height (inches)36
  • Width (inches)18
  • Depth (inches)12
Related
  • Material mainGalvanized steel
  • Material secondaryPowder coated steel
  • Designed inUnited States
  • Manufactured inUnited States
  • Weight Net (Lbs)66
Classification
  • BIMobject CategoryFire Products - Sprinkler Systems
  • IFC classificationValve
  • ETIM CodeEG000056
  • ETIM NameFire protection systems
  • UNSPSC nameFire sprinkler systems
  • UNSPSC code46191602
  • CSI MasterFormat 2014 Code21 00 00
  • CSI MasterFormat 2014 TitleFire Suppression
  • OmniClass Number23-29 33 00
  • OmniClass TitleFire Suppression System Components
  • CSI UniFormat II CodeD40
  • CSI UniFormat II TitleFIRE PROTECTION

Region availability

Asia Europe Africa South America Oceania North America
Afghanistan
Albania
Algeria
Argentina
Australia
Belize
Armenia
Austria
Angola
Bolivia
Fiji
Canada
Azerbaijan
Belarus
Benin
Brazil
New Caledonia
Costa Rica
Bangladesh
Belgium
Botswana
Chile
New Zealand
Cuba
Bhutan
Bosnia and Herzegovina
Burkina Faso
Colombia
Papua New Guinea
Dominican Republic
Cambodia
Bulgaria
Burundi
Ecuador
Solomon Islands
El Salvador
China
Croatia
Cameroon
Falkland Islands (Islas Malvinas)
Timor-Leste
Greenland
Georgia
Cyprus
Central African Republic
French Guiana
Vanuatu
Guatemala
India
Czech Republic
Chad
Guyana
Haiti
Indonesia
Denmark
Côte d'Ivoire
Paraguay
Honduras
Iran
Estonia
Democratic Republic of the Congo
Peru
Jamaica
Iraq
Finland
Djibouti
Suriname
Mexico
Israel
France
Egypt
Uruguay
Nicaragua
Japan
Germany
Equatorial Guinea
Venezuela
Panama
Jordan
Greece
Eritrea
Puerto Rico
Kazakhstan
Hungary
Eswatini
The Bahamas
Kuwait
Iceland
Ethiopia
United States
Kyrgyzstan
Ireland
Gabon
Laos
Italy
Ghana
Lebanon
Latvia
Guinea
Malaysia
Lithuania
Guinea-Bissau
Mongolia
Luxembourg
Kenya
Myanmar (Burma)
Moldova
Lesotho
Nepal
Montenegro
Liberia
North Korea
Netherlands
Libya
Oman
North Macedonia
Madagascar
Pakistan
Norway
Malawi
Palestine
Poland
Mali
Philippines
Portugal
Mauritania
Qatar
Romania
Morocco
Saudi Arabia
Russia
Mozambique
South Korea
Serbia
Namibia
Sri Lanka
Slovakia
Niger
Syria
Slovenia
Nigeria
Taiwan
Spain
Republic of the Congo
Tajikistan
Svalbard and Jan Mayen
Rwanda
Thailand
Sweden
Senegal
Türkiye
Switzerland
Sierra Leone
Turkmenistan
Ukraine
Somalia
United Arab Emirates
United Kingdom
South Africa
Uzbekistan
South Sudan
Vietnam
Sudan
Yemen
Tanzania
The Gambia
Togo
Tunisia
Uganda
Western Sahara
Zambia
Zimbabwe