Publish your products
Model 8611 Corner RiserPACK

Model 8611 Corner RiserPACK

4.6 out of 5 stars4.6(10 reviews)

AGF's commercial RiserPACK Model 8611 is a riser manifold for NFPA 13 fire sprinkler systems and is designed to fit into a corner to minimize protruding and comply with ADA Standards. Model 8611 includes a flow switch, TESTanDRAIN Model 1011A with included pressure relief valve and trim, Model 7600 3-way universal gauge valve, and a Model 7500 pressure gauge. Available with a steel body in sizes 2"-6", orifice sizes 3/8" (K 2.8) - 25K, and a groove x groove connection. AGF's corner manifold is available with a right or left drain to accommodate every installation configuration.

Specification
  • Model 8611 Commercial Corner RiserPACK

    1. 2.1 SPRINKLER SPECIALTY PIPE FITTINGS - Flow Detection and Test Assemblies:
      1. Product: Commercial Model M8611. Includes a flow switch, TESTanDRAIN Model 1011A, Model 7600 3-way Globe Valve, and a M7500 Pressure Gauge and a model M7000 Pressure Relief Valve.
        1. Riser Model: Pre-Assembled TESTanDRAIN Riser 2, 2-1/2, 3, 4, and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm):
          1. Inlet and Outlet (Schedule 10 steel): Grooved 2, 2-1/2, 3, 4 and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm) Models.
          2. Schedule 10 fabricated steel body with 3mil (.08 mm) powder coated red finish.
          3. Standard: UL's "Product iQ" listing, or "Approval Guide," published by FM Global, listing. NFPA 13.
          4. Pressure Rating: 300 psig (2070 kPa).
          5. Size: Same as connected piping.

    ** NOTE TO SPECIFIER ** Delete valve not required.

    1. Valve Model 1011 TESTanDRAIN valve for a 2 inch (51 mm) Model:
      1. 1 inch (25 mm) FNPT.

    ** NOTE TO SPECIFIER ** Delete orifice size not required.

    1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
    2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
    3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
    4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
    5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition

    ** NOTE TO SPECIFIER ** Delete orifice size not required.

    1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
    2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
    3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
    4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
    5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
    6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
    1. Valve Model 1011 TESTanDRAIN valve for a 4 or 6 inch (102 mm, 152 mm) Models:
      1. 2 inch FNPT.

    ** NOTE TO SPECIFIER ** Delete orifice size not required.

    1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
    2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
    3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
    4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
    5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
    6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
    7. Test Orifice Size: Nominal 25.2K, as required by NFPA 13, latest edition.
    8. Water flow alarm switch.
    9. Pressure Gauge: AGF Model 7500.
    10. 1/4 inch, 3-way globe valve: AGF Model 7600
    11. Pressure Relief Valve and Drainage Piping: AGF Model 7000 or AGF Lockable Model 7000L

    ** NOTE TO SPECIFIER ** Delete pressure rating not required.

    1. Pressure Rating: Factory rated at 175 PSI.
    2. Pressure Rating: 200 PSI.
    3. Pressure Rating: 225 PSI.
    4. Pressure Rating: 300 PSI.
    5. Body Material: Bronze body and stainless steel spring.
    6. Components: Nylobraid flexible tube, Two 1/2 inch (13 mm) NPT by barbed 90 degree elbows, external identification plate and integral flushing handle to remove debris.
    7. 1/2 inch (13 mm) MIPT inlet, 1/2 inch (13 mm) FIPT outlet.
    8. Relief pressure shall be factory set to project specifications.
    9. Relief valve shall operate to the OPEN position between 90% and 105% of the set pressure.
    10. Relief valve shall reseat or CLOSE at a minimum of 80% of set pressure.
Technical specification
  • Unique ref.AGF-Corner-Riser
  • Product familyAGF Fire Sprinkler Products
  • Product groupRiserPACK®
  • Date of publishing2022-03-02
  • Edition number1
Related
  • Material mainPowder coated steel
  • Designed inUnited States
  • Manufactured inUnited States
Classification
  • BIMobject CategoryFire Products - Sprinkler Systems
  • CSI MasterFormat 2014 Code21 00 00
  • CSI MasterFormat 2014 TitleFire Suppression
  • OmniClass Number23-29 33 00
  • OmniClass TitleFire Suppression System Components
  • CSI UniFormat II CodeD40
  • CSI UniFormat II TitleFIRE PROTECTION

Region availability

Asia Europe Africa South America Oceania North America
Afghanistan
Albania
Algeria
Argentina
Australia
Belize
Armenia
Austria
Angola
Bolivia
Fiji
Canada
Azerbaijan
Belarus
Benin
Brazil
New Caledonia
Costa Rica
Bangladesh
Belgium
Botswana
Chile
New Zealand
Cuba
Bhutan
Bosnia and Herzegovina
Burkina Faso
Colombia
Papua New Guinea
Dominican Republic
Cambodia
Bulgaria
Burundi
Ecuador
Solomon Islands
El Salvador
China
Croatia
Cameroon
Falkland Islands (Islas Malvinas)
Timor-Leste
Greenland
Georgia
Cyprus
Central African Republic
French Guiana
Vanuatu
Guatemala
India
Czech Republic
Chad
Guyana
Haiti
Indonesia
Denmark
Côte d'Ivoire
Paraguay
Honduras
Iran
Estonia
Democratic Republic of the Congo
Peru
Jamaica
Iraq
Finland
Djibouti
Suriname
Mexico
Israel
France
Egypt
Uruguay
Nicaragua
Japan
Germany
Equatorial Guinea
Venezuela
Panama
Jordan
Greece
Eritrea
Puerto Rico
Kazakhstan
Hungary
Eswatini
The Bahamas
Kuwait
Iceland
Ethiopia
United States
Kyrgyzstan
Ireland
Gabon
Laos
Italy
Ghana
Lebanon
Latvia
Guinea
Malaysia
Lithuania
Guinea-Bissau
Mongolia
Luxembourg
Kenya
Myanmar (Burma)
Moldova
Lesotho
Nepal
Montenegro
Liberia
North Korea
Netherlands
Libya
Oman
North Macedonia
Madagascar
Pakistan
Norway
Malawi
Palestine
Poland
Mali
Philippines
Portugal
Mauritania
Qatar
Romania
Morocco
Saudi Arabia
Russia
Mozambique
South Korea
Serbia
Namibia
Sri Lanka
Slovakia
Niger
Syria
Slovenia
Nigeria
Taiwan
Spain
Republic of the Congo
Tajikistan
Svalbard and Jan Mayen
Rwanda
Thailand
Sweden
Senegal
Türkiye
Switzerland
Sierra Leone
Turkmenistan
Ukraine
Somalia
United Arab Emirates
United Kingdom
South Africa
Uzbekistan
South Sudan
Vietnam
Sudan
Yemen
Tanzania
The Gambia
Togo
Tunisia
Uganda
Western Sahara
Zambia
Zimbabwe