Single Stage Infrared Heater, Model UXR

Single Stage Infrared Heater, Model UXR

Includes all of the features in a Model UX plus... the burner box is sealed for rugged, harsh environments and heat-treated aluminized is standard tube supplied. CSA approved for outdoor use.

  • Approved for outdoor use
  • 40,000 to 220,000 btu/h
  • Natural gas and LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated controls compartment – electronics out of air stream, burner can run during servicing
  • Self diagnostic ignition module
  • Parabolic aluminum reflectors – most efficient in industry
  • Direct spark ignition
  • Vented or unvented
  • Operating status light
  • Low voltage controls
  • Jet stream burner – improved heat distribution, better combustion
  • Heavy duty couplings – no leaks, cannot be over tightened
  • UXR features burner box sealed for outdoor conditions
  • Rubber gaskets
  • Silicone used to seal corners and joints
  • Weather resistant electrical components used for exterior connections
  • Stainless steel burner boxes available as well as tubing and reflectors
  • Units are wind resistant
  • Three year warranty on all components
  • Seven year warranty on aluminized heat exchanger
  • 10 year warranty on aluminized heat exchanger with post purge feature


规格
  • Low-Intensity Single Stage Infrared Tube Heaters with minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. 

    Assemblies shall be CSA approved low-intensity heater to the latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a positive pressure burner system, where exhaust gases and other products of combustion are not routed through the blower. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz.
    Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with less than 10 surfaces will not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project. 

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with alternate systems.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
技术规格
  • 唯一参考uxr
  • 产品系列Single Stage Infrared Heaters
  • 产品组Low Intensity - Series U
  • 类型对象(单个对象)
  • 发布日期2021-02-16
  • 版本号1
相关
  • 主材料
  • 次要材料
  • 设计国家/地区加拿大
  • 制造国家/地区加拿大
分类
  • BIMobject 类别暖通空调 - 加热装置
  • UNSPSC 名称Tubular heaters
  • UNSPSC 代码40101822
  • Uniclass 2015 代码Pr_70_60_36_72
  • Uniclass 2015 说明Radiant tube heaters
  • CSI MasterFormat 2014 代码23 55 23
  • CSI MasterFormat 2014 标题Gas-Fired Radiant Heaters
  • OmniClass 编号23-33 15 17 13
  • OmniClass 标题Fuel Fired HVAC Radiant Heaters
  • CSI UniFormat II 代码D30
  • CSI UniFormat II 标题HVAC

发售地区

北美
伯利兹
加拿大
危地马拉
古巴
哥斯达黎加
圣卢西亚
圣基茨和尼维斯
圣巴泰勒米
圣皮埃尔和密克隆群岛
多米尼克
多米尼加共和国
安圭拉
安提瓜和巴布达
尼加拉瓜
巴哈马
巴巴多斯
巴拿马
库拉索
开曼群岛
格林纳达
格陵兰岛
法属圣马丁
波多黎各
洪都拉斯
海地
牙买加
特克斯和凯科斯群岛
特立尼达和多巴哥
瓜德罗普
百慕大
美国
美属维尔京群岛
聖文森與格瑞那丁
英属维尔京群岛
荷属圣马丁
荷蘭加勒比區
萨尔瓦多
蒙塞拉特岛
阿鲁巴
马提尼克
墨西哥