发布您的产品
Negative Pressure Infrared Heater - Series TVX

Negative Pressure Infrared Heater - Series TVX

The Series TVX negative pressure multi-burner system was designed to use two or more radiant tube heaters in a variety of applications, these systems offer significant operating benefits that are not easily obtainable with traditional infrared tube heaters.

Flexible layouts (Herringbone, Fork, "T", Flag, etc.) can be adapted to fit a wide range of applications heating and space requirements. Available input rates 60 / 80 / 100 / 125 / 150 / 175 / 205 / 220 MBH all featuring a two-stage configuration.

Features

  •   Input rates 60 to 220 MBH
  •   Lengths –  from 20’ to 60’
  •   Two-stage for comfort control 
  •   100% efficient reflector 
  •   Sealed burner box 
  •   3 try ignition 
  •   Integral safety switch  
  •   Simple controls 
  •   Multi-zone capability
  •   State-of-the-art pump with ECM motor
  •   Up to 525 MBH on single vent penetration
  •   Easy setup and commissioning 
  •   Standard gas flex and shut off valve are used
  •   Installation benefits – fewer vents needed
  •   Optional Equipment:
    • Elbows, Utube, outside air kit
    • Side shields, deco grille, bottom shield
规格
  • Low Intensity, Two-Stage, Negative pressure Infrared Tube Heating System - Heavy duty industrial/commercial infrared heating system, featuring the best overall radiant performance in the industry. Firing rates as called for in the Contract documents within the range of 60/45 MBH to 220/165 MBH. 100% efficient reflector design with minimum 65% radiant factor as determined by independent lab testing to EN416 Standard. Baffles required as per manufacturer’s instructions. Product shall be Custom-designed, Negative Pressure, Low-Intensity Infrared Heating System: Model TVX as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks to be conducted with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish design with emitter tubes fully recessed within reflector. Reflectors shall have a minimum of 10 reflective surfaces. Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024-inch thickness aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall always extend below the lowest position of the tubing and include standard end caps. Reflector end caps: Shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4-inch (102 mm) diameter, minimum 16-gauge thickness, hot rolled steel, heat-treated type 1 aluminized steel or type 409 stainless steel materials. Heat Uniformity: Burner shall distribute hot gases along the length of the emitter tubes. Combustion Tube shall be 4 inches (102 mm) diameter, 16-gauge, heat-treated type 1 aluminized steel tubing for all firing rates. Hot rolled steel shall not be allowed. The combustion tube shall incorporate a continuously welded, 11-gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16-gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands. Exhaust pump motor shall be totally enclosed requiring no oiling and shall be equipped with overcurrent protection. It shall be one of A. For systems up to 250,000 BTU/Hr - Permanent Split Capacitor (PSC) type, Electrical supply: 120V, 60Hz, 1 PH, 1 A.B. For systems up to 525,000 BTU/Hr - Electrically Commutated Motor (ECM) Electrical supply 120V, 60Hz, 1 PH, 5 A. This product was specified based on best practice design to meet the specific engineering design criteria for this project. No Substitution Permitted. Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:- Independent lab testing to EN416 standard dated no later than 6 months from date of submission showing minimum 65% radiant factor.- Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.- Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model - Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).

技术规格
  • 唯一参考tvx
  • 产品系列Negative Pressure Systems
  • 产品组Series TVX
  • 类型对象(单个对象)
  • 发布日期2021-02-16
  • 版本号1
相关
  • 主材料
  • 次要材料
  • 设计国家/地区加拿大
  • 制造国家/地区加拿大
分类
  • BIMobject 类别暖通空调 - 加热装置
  • IFC 分类小型供暖器
  • UNSPSC 名称Space heaters
  • UNSPSC 代码40101819
  • Uniclass 2015 代码Pr_70_60_36_72
  • Uniclass 2015 说明Radiant tube heaters
  • CSI MasterFormat 2014 代码23 55 23
  • CSI MasterFormat 2014 标题Gas-Fired Radiant Heaters
  • OmniClass 编号23-33 15 17 13
  • OmniClass 标题Fuel Fired HVAC Radiant Heaters
  • CSI UniFormat II 代码D30
  • CSI UniFormat II 标题HVAC

发售地区

欧洲 北美 亚洲
丹麦
伯利兹
不丹
乌克兰
加拿大
中国
俄罗斯
危地马拉
乌兹别克斯坦
保加利亚
古巴
亚美尼亚
克罗地亚
哥斯达黎加
印度
冰岛
圣卢西亚
印度尼西亚
列支敦士登
圣基茨和尼维斯
台湾
匈牙利
圣巴泰勒米
吉尔吉斯斯坦
北马其顿
圣皮埃尔和密克隆群岛
哈萨克斯坦
卢森堡
多米尼克
土库曼斯坦
圣马力诺
多米尼加共和国
圣诞岛
塞尔维亚
安圭拉
塔吉克斯坦
塞浦路斯
安提瓜和巴布达
大韓
奥兰
尼加拉瓜
孟加拉国
奥地利
巴哈马
尼泊尔
安道尔
巴巴多斯
巴基斯坦
希腊
巴拿马
文莱达鲁萨兰国
德国
库拉索
斯里兰卡
意大利
开曼群岛
新加坡
拉脱维亚
格林纳达
日本
挪威
格陵兰岛
朝鲜
捷克共和国
法属圣马丁
柬埔寨
摩尔多瓦
波多黎各
格鲁吉亚
摩纳哥
洪都拉斯
泰国
斯洛伐克
海地
澳门
斯洛文尼亚
牙买加
科科斯(基林)群岛
斯瓦尔巴特群岛
特克斯和凯科斯群岛
缅甸
格恩西岛
特立尼达和多巴哥
老挝
梵蒂冈
瓜德罗普
英属印度洋领地
比利时
百慕大
菲律宾
法国
美国
蒙古
法罗群岛
美属维尔京群岛
越南
波兰
聖文森與格瑞那丁
阿塞拜疆
波斯尼亚 黑塞哥维那
英属维尔京群岛
香港
泽西岛
荷属圣马丁
马尔代夫
爱尔兰
荷蘭加勒比區
马来西亚
爱沙尼亚
萨尔瓦多
瑞典
蒙塞拉特岛
瑞士
阿鲁巴
白俄罗斯
马提尼克
直布罗陀
墨西哥
立陶宛
罗马尼亚
芬兰
英国
荷兰
葡萄牙
西班牙
阿尔巴尼亚
马恩岛
马耳他
黑山