发布您的产品
Single Stage CNG Infrared Heater, Model LA 750

Single Stage CNG Infrared Heater, Model LA 750

The series 750 low-temperature tube heater, was designed and approved* for use in maintenance facilities where specialty fueled vehicles are repaired. The patent-pending tube system maintains tube temperatures less than 750°F while providing even heat distribution.

  • Ideal for CNG or LNG-fueled vehicle repair facilities
  • Tube temperature below 750°F
  • End-to-end output variance is less than 15%
  • Largest burner rates in industry up to 100,000 BTU/HR
  • Single stage
  • Separated controls compartment
  • External Sealed Blower
  • Self-diagnostic ignition module
  • Parabolic aluminum reflectors
  • Heavy-duty couplings

*approved and certified by CSA to meet maximum tube temperature of 750˚ F (399˚C) in accordance with NFPA 30A 7.6.6

规格
  • Low Intensity, Low Clearance, Low temperature, Even heat Single Stage Infrared Tube Heaters.  Heavy-duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents, either 60 MBH or 100 MBH. Designed for low clearance, even heat applications in specialty fueled vehicle or similar facilities that must comply with NFPA 30A 7.6.6, requiring maximum heater surface temperature of 750°F. All Series 750 units include our patented design, which provides unequalled even heat distribution with end to end output variance of less than 15%. Baffles required as per manufacturer’s instructions. Assemblies shall be CSA approved low-intensity heater to latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications and shall also be CSA tested and certified to comply with NFPA 30A 7.6.6. Burner shall be a positive pressure burner system where exhaust gases and other products of combustion are not routed through the blower.   The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) and draw no more than 1 Amp at 120VAC, 60Hz.

    Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks with the burner operating. Reflector shall have a minimum 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with fewer than 10 surfaces will not be allowed as they allow energy to bounce back to the main heat exchanger tubing. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, type 1 aluminized steel tubing and be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution must include the following material for consideration, or bid will be deemed unqualified and rejected:

    • Independent testing to show a maximum of 750° F tube temperatures, and even distribution of hot gases along the complete length of the emitter tube with a maximum variance of 15%.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with an alternate system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model.
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
       
技术规格
  • 唯一参考cng-la
  • 产品系列CNG Series 750
  • 产品组Single Stage - Model LA
  • 类型对象(单个对象)
  • 发布日期2021-02-16
  • 版本号1
相关
  • 主材料
  • 次要材料
  • 设计国家/地区加拿大
  • 制造国家/地区加拿大
分类
  • BIMobject 类别暖通空调 - 加热装置
  • UNSPSC 名称Tubular heaters
  • UNSPSC 代码40101822
  • Uniclass 2015 代码Pr_70_60_36_72
  • Uniclass 2015 说明Radiant tube heaters
  • CSI MasterFormat 2014 代码23 55 23
  • CSI MasterFormat 2014 标题Gas-Fired Radiant Heaters
  • OmniClass 编号23-33 15 17 13
  • OmniClass 标题Fuel Fired HVAC Radiant Heaters
  • CSI UniFormat II 代码D30
  • CSI UniFormat II 标题HVAC

发售地区

北美
伯利兹
加拿大
危地马拉
古巴
哥斯达黎加
圣卢西亚
圣基茨和尼维斯
圣巴泰勒米
圣皮埃尔和密克隆群岛
多米尼克
多米尼加共和国
安圭拉
安提瓜和巴布达
尼加拉瓜
巴哈马
巴巴多斯
巴拿马
库拉索
开曼群岛
格林纳达
格陵兰岛
法属圣马丁
波多黎各
洪都拉斯
海地
牙买加
特克斯和凯科斯群岛
特立尼达和多巴哥
瓜德罗普
百慕大
美国
美属维尔京群岛
聖文森與格瑞那丁
英属维尔京群岛
荷属圣马丁
荷蘭加勒比區
萨尔瓦多
蒙塞拉特岛
阿鲁巴
马提尼克
墨西哥