发布您的产品
nVent RackChiller Rear Door Cooler, Passive
nVent

nVent RackChiller Rear Door Cooler, Passive

RackChiller Rear Door Cooler (RDC) Water Heat Exchanger is designed for managing high heat load cooling requirements within high-density server, computing and storage racks. The RDC installs on equipment racks as a separate rear door with an extra frame, enabling it to be retrofitted to existing racks. Heat dissipated by the rack equipment will be removed by a air-to-liquid heat exchanger and transfered into the facility water circuit, adding no heat to the IT room. The entire system is integrated within an aesthetically framed perforated door with protective covers to isolate the liquid source and cooling loop from the rack-mounted equipment.

规格
  • Features & Benefits

    • Fanless solution, no noise, no additional power consumption, low maintenance
    • Frame solution separates coil and condensate management from the rack-mounted equipment
    • Rear space inside the cabinet is completely available for power distribution and cable management
    • Easily adapts to nVent cabinets; contact nVent to request information for integrating with third party cabinet
    • Temperature sensors on air supply and return side
    • Optional control system with Modbus TCP and SNMP v2c interface
    • Optional water flow, pressure and temperature sensors included with the water control package allow for water monitoring and regulation according to actual heat load
    • Optional local display

    For trouble-free operation it is recommended to use the water connection set and the optional accessories.The cooling capacity is determined under the following conditions: delta p water: < 100 kPa; delta p air: 15 Pa; water flow temperature: 12 °C / 53.6 °F; outlet temperature 24 °C / 75.2 °F; water flow: 4.8 m³/h / 21.1 gal/min; Airflow: Depending on cooling module see Diagram Performance Map.

技术规格
  • 唯一参考RackChiller-Rear-Door-Cooler-Passive
  • 产品系列nVent Data Center Solutions
  • 产品组Rear Door Heat Exchangers
  • 类型对象(单个对象)
  • 发布日期2023-03-16
  • 版本号1
相关
  • 主材料
  • 设计国家/地区美国
  • 制造国家/地区美国
分类
  • BIMobject 类别暖通空调 - Heat Exchanger
  • ETIM 代码EG015220
  • ETIM 名称Heat exchangers
  • Uniclass 2015 代码Pr_60_60_38
  • Uniclass 2015 说明Calorifiers and plate heat exchangers
  • CSI MasterFormat 2014 代码23 57 00
  • CSI MasterFormat 2014 标题Heat Exchangers for HVAC
  • OmniClass 编号23-27 23 00
  • OmniClass 标题Heat Exchangers

发售地区

北美
加拿大
美国