    StegoCrawl Wrap Perimeter Vapor Barrier utilizes the same industry-leading technology as Stego Wrap Vapor Barrier, but is specifically created for use in crawl spaces.

    StegoCrawl Wrap 15-Mil Vapor Barrier is a Class I vapor retarder as defined by the 2009 IRC R601.3, and it is used to encapsulate crawl space floors and walls to protect the building envelope from moisture vapor and soil gas transmission. 

    StegoCrawl Wrap is a multi-layer plastic extrusion manufactured with only the highest grade of prime, virgin polyolefin resins.  

    This product is 5' x 200' -- a narrower roll easier to use in vertical placement on foundation walls and columns

    Its many features include:

    • Clean, white color to brighten your crawl space
    • Proportioned with ease of use in vertical wall coverage in mind
    • Increased push-through protection to help prevent punctures
    • Lighter weight roll sizes to make installation easier
    • Made In USA
    规格
    • CRAWLSPACE LINER

      PART 1- GENERAL

      1.1 SUMMARY

      A. Products supplied under this section. 

      1 Crawlspace liner and installation accessories for installation in a crawlspace.

      B. Related sections:

      1. Section 07 26 00 Vapor Retarders

      1.2 REFERENCES

      A. American Society for Testing and Materials (ASTM): 

      1. ASTM E1745-17 Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill Under Concrete Slabs.

      1.3 SUBMITTALS

      A. Quality control/ assurance:

      1. Summary of test results per paragraph 9.3 of ASTM E1745.

      2. Manufacturer's samples and literature.

      3. Manufacturer's installation instructions for placement, seaming, wall termination, and penetration repair instructions.

      4. All mandatory ASTM E1745 testing must be performed on a single production roll per ASTM E1745 Section 8.1.

      PART 2- PRODUCTS

      2.1 MATERIALS

      A. Liner shall have all of the following qualities:

      1. Maintain permeance of less than 0.01 perms [grains/ft2 x hr x inHg)] as tested in accordance with mandatory conditioning tests per ASTM E1745 Section 7.1 (7.1.1-7.1.5).

      2. Other performance criteria:

      a. Strength and Longevity: ASTM E1745.

      b. Thickness: 15 mils minimum

      B. Vapor barrier products:

      1. Basis of Design: StegoCrawl Vapor Barrier (15-mi, white) by Stego Industries LLC., (877) 464-7834

      2. No substitutions. 

      2.2 ACCESSORIES

      A. Seams:

      1. StegoCrawl Tape by Stego Industries LLC., (877) 464-7834. 

      B. Penetrations of Liner:

      1. StegoCrawl Tape by Stego Industries LLC., (877) 464-7834. 

      C. Perimeter / edge seal:

      1. StegoCrawl Term Bar by Stego Industries LLC., (877) 464-7834. 

      2. 1. StegoTack Tape (double sided) by Stego Industries LLC., (877) 464-7834. 

      PART 3- EXECUTIONS

      3.1 PREPARATION

      A. Remove debris from crawlspace.

      3.2 INSTALLATION

      A. Install liner in accordance to manufacturer's instructions.

      1. Turn StegoCrawl Vapor Barrier up the foundation wall to a minimum height of six inches above the outside/ exterior grade or in compliance with local building codes and terminate with StegoCrawl Term Bar. To form a complete seal, apply StegoTack Tape to the foundation wall prior to installing StegoCrawl Term Bar. 

      2. Seal StegoCrawl Vapor Barrier around all penetrations and columns using StegoCrawl Tape and/or StegoTack Tape.

      3. Place StegoCrawl Vapor Barrier directly over the crawlspace floor. Where consistent with local code, if rigid insulation is to be used, install StegoCrawl Vapor Barrier prior to insulation (under insulation and between the foundation wall and insulation). 

      4. Overlap seams a minimum of six inches and seal with StegoCrawl Tape. Some codes require a minimum of a twelve inch overlap. Check appropriate codes prior to installation.

      5. No penetration of the liner is allowed except for reinforcing steel and permanent utilities.

      6. Repair damaged areas by cutting patches of vapor barrier, overlapping damaged area 6 inches and taping all sides with tape. 

      END OF SECTION. 

    技术规格
    • 唯一参考stego007
    • 产品系列Thermal and Moisture Protective Products
    • 产品组StegoCrawl Wrap
    • 类型对象(单个对象)
    • 发布日期2019-02-01
    • 版本号2
    相关
    • 主材料聚乙烯
    • 设计国家/地区United States
    • 制造国家/地区United States
    分类
    • BIMobject 类别建筑材料 - Waterproofing & Membranes
    • CSI MasterFormat 2014 代码07 26 00
    • CSI MasterFormat 2014 标题Vapor Retarders

    发售地区

    North America Oceania South America
    Anguilla
    Australia
    Chile
    Antigua and Barbuda
    New Zealand
    Peru
    Aruba
    Barbados
    Belize
    Bermuda
    British Virgin Islands
    Canada
    Caribbean Netherlands
    Cayman Islands
    Collectivity of Saint Martin
    Costa Rica
    Cuba
    Curaçao
    Dominica
    Dominican Republic
    El Salvador
    Greenland
    Grenada
    Guadeloupe
    Guatemala
    Haiti
    Honduras
    Jamaica
    Martinique
    Mexico
    Montserrat
    Nicaragua
    Panama
    Puerto Rico
    Saint Kitts and Nevis
    Saint Lucia
    Saint Pierre and Miquelon
    Saint Vincent and the Grenadines
    Saint-Barthélemy
    Sint Maarten
    The Bahamas
    Trinidad and Tobago
    Turks and Caicos Islands
    U.S. Virgin Islands
    United States