These panels are ideal for specification on applications where roof transitions are required. The simplicity of the pan design combined with corrective leveling provides superior flatness and allows for greater workability on site.
Trim
All flashing and trim shall be fabricated by manufacturer or qualified fabricator. Flashing shall be PAC-CLAD aluminum (.032 – .063 gauge as specified) or PAC-CLAD steel (24 gauge or 22 gauge as specified). A 30-year non-prorated finish warranty can be supplied covering finish performance. Vinyl masking is recommended on all fabrication applications where extra handling is expected. NOTE: The strippable film must be removed immediately after installation.
Installation
Snap-On panels shall be installed over solid decking (5/8” plywood, nailboard insulation or equal) with an underlayment of 30# (min.) roofing felt applied horizontally from eave to ridge. Panels shall be fastened using Petersen Aluminum nonpenetrating clips, fastening on 18” centers (max.). Minimum slope at 3:12 pitch. Consult a local architect or engineer for requirements of local codes and conditions.
Curved Panels
The 1” high Snap-On standing seam panel can be curved to a concave or convex radius, with a minimum radius of 9’. This panel is ideal for barrel vaults and entrance ways. Curved panels must be installed over a waterproofed solid substrate.
Доступність регіону
Північна Америка |
---|
United States |