Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK
    AGF Manufacturing

    Model 8611 Corner RiserPACK

    4.6 out of 5 stars4.6(12 reviews)

    AGF's commercial RiserPACK Model 8611 is a riser manifold for NFPA 13 fire sprinkler systems and is designed to fit into a corner to minimize protruding and comply with ADA Standards. Model 8611 includes a flow switch, TESTanDRAIN Model 1011A with included pressure relief valve and trim, Model 7600 3-way universal gauge valve, and a Model 7500 pressure gauge. Available with a steel body in sizes 2"-6", orifice sizes 3/8" (K 2.8) - 25K, and a groove x groove connection. AGF's corner manifold is available with a right or left drain to accommodate every installation configuration.

    สเปคสินค้า
    • Model 8611 Commercial Corner RiserPACK

      1. 2.1 SPRINKLER SPECIALTY PIPE FITTINGS - Flow Detection and Test Assemblies:
        1. Product: Commercial Model M8611. Includes a flow switch, TESTanDRAIN Model 1011A, Model 7600 3-way Globe Valve, and a M7500 Pressure Gauge and a model M7000 Pressure Relief Valve.
          1. Riser Model: Pre-Assembled TESTanDRAIN Riser 2, 2-1/2, 3, 4, and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm):
            1. Inlet and Outlet (Schedule 10 steel): Grooved 2, 2-1/2, 3, 4 and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm) Models.
            2. Schedule 10 fabricated steel body with 3mil (.08 mm) powder coated red finish.
            3. Standard: UL's "Product iQ" listing, or "Approval Guide," published by FM Global, listing. NFPA 13.
            4. Pressure Rating: 300 psig (2070 kPa).
            5. Size: Same as connected piping.

      ** NOTE TO SPECIFIER ** Delete valve not required.

      1. Valve Model 1011 TESTanDRAIN valve for a 2 inch (51 mm) Model:
        1. 1 inch (25 mm) FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      1. Valve Model 1011 TESTanDRAIN valve for a 4 or 6 inch (102 mm, 152 mm) Models:
        1. 2 inch FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      7. Test Orifice Size: Nominal 25.2K, as required by NFPA 13, latest edition.
      8. Water flow alarm switch.
      9. Pressure Gauge: AGF Model 7500.
      10. 1/4 inch, 3-way globe valve: AGF Model 7600
      11. Pressure Relief Valve and Drainage Piping: AGF Model 7000 or AGF Lockable Model 7000L

      ** NOTE TO SPECIFIER ** Delete pressure rating not required.

      1. Pressure Rating: Factory rated at 175 PSI.
      2. Pressure Rating: 200 PSI.
      3. Pressure Rating: 225 PSI.
      4. Pressure Rating: 300 PSI.
      5. Body Material: Bronze body and stainless steel spring.
      6. Components: Nylobraid flexible tube, Two 1/2 inch (13 mm) NPT by barbed 90 degree elbows, external identification plate and integral flushing handle to remove debris.
      7. 1/2 inch (13 mm) MIPT inlet, 1/2 inch (13 mm) FIPT outlet.
      8. Relief pressure shall be factory set to project specifications.
      9. Relief valve shall operate to the OPEN position between 90% and 105% of the set pressure.
      10. Relief valve shall reseat or CLOSE at a minimum of 80% of set pressure.
    สเปคสินค้าด้านเทคนิค
    • Unique ref.AGF-Corner-Riser
    • Product familyAGF Fire Sprinkler Products
    • กลุ่มผลิตภัณฑ์RiserPACK®
    • วันที่เผยเเพร่2022-03-02
    • หมายเลขฉบับ1
    สิ่งที่เกี่ยวข้อง
    • วัสดุหลักPowder coated steel
    • ออกเเบบโดยสหรัฐอเมริกา
    • ผลิตโดยสหรัฐอเมริกา
    การจำแนกประเภท
    • หมวดหมู่ BIMobjectผลิตภัณฑ์ดับเพลิง - ระบบกระจายน้ำดับเพลิง
    • CSI MasterFormat 2014 Code21 00 00
    • CSI MasterFormat 2014 TitleFire Suppression
    • OmniClass Number23-29 33 00
    • OmniClass TitleFire Suppression System Components
    • CSI UniFormat II CodeD40
    • CSI UniFormat II TitleFIRE PROTECTION

    พื้นที่การขาย

    เอเชีย ยุโรป แอฟริกา อเมริกาใต้ โอเชียเนีย อเมริกาเหนือ
    กัมพูชา
    กรีซ
    กานา
    โคลอมเบีย
    ติมอร์ตะวันออก
    กรีนแลนด์
    กาตาร์
    โครเอเชีย
    กาบอง
    ชิลี
    นิวแคลิโดเนีย
    กัวเตมาลา
    เกาหลีใต้
    เช็กเกีย
    กินี
    ซูรินาเม
    นิวซีแลนด์
    คอสตาริกา
    เกาหลีเหนือ
    เซอร์เบีย
    กินี-บิสเซา
    บราซิล
    ปาปัวนิวกินี
    คิวบา
    คาซัคสถาน
    ไซปรัส
    แกมเบีย
    โบลิเวีย
    ฟิจิ
    แคนาดา
    คีร์กีซสถาน
    เดนมาร์ก
    โกตดิวัวร์
    ปารากวัย
    วานูอาตู
    จาเมกา
    คูเวต
    นอร์เวย์
    คองโก
    เปรู
    หมู่เกาะโซโลมอน
    นิการากัว
    จอร์เจีย
    เนเธอร์แลนด์
    คองโก
    เฟรนช์เกียนา
    ออสเตรเลีย
    บาฮามาส
    จอร์แดน
    บอสเนียและเฮอร์เซโกวีนา
    เคนยา
    เวเนซุเอลา
    เบลีซ
    จีน
    บัลแกเรีย
    แคเมอรูน
    สาธารณรัฐสหกรณ์กายอานา
    ปานามา
    ซาอุดีอาระเบีย
    บาร์เบโดส
    จิบูตี
    หมู่เกาะฟอล์กแลนด์
    เปอร์โตริโก
    ซีเรีย
    เบลเยียม
    ชาด
    อาร์เจนตินา
    เม็กซิโก
    ญี่ปุ่น
    โปรตุเกส
    ซิมบับเว
    อุรุกวัย
    สหรัฐอเมริกา
    ตุรกี
    โปแลนด์
    ซูดาน
    เอกวาดอร์
    สาธารณรัฐโดมินิกัน
    เติร์กเมนิสถาน
    ฝรั่งเศส
    เซเนกัล
    เอลซัลวาดอร์
    ไต้หวัน
    ฟินแลนด์
    เซาท์ซูดาน
    ฮอนดูรัส
    ทาจิกิสถาน
    มอนเตเนโกร
    เซียร์ราลีโอน
    เฮติ
    ไทย
    มอลโดวา
    แซมเบีย
    เนปาล
    มาซิโดเนียเหนือ
    โซมาเลีย
    บังกลาเทศ
    ยูเครน
    ดินแดนซาฮาราตะวันตก
    ปากีสถาน
    เยอรมนี
    ตูนิเซีย
    ปาเลสไตน์
    รัสเซีย
    โตโก
    พม่า
    โรมาเนีย
    แทนซาเนีย
    ฟิลิปปินส์
    ลักเซมเบิร์ก
    นามิเบีย
    ภูฏาน
    ลัตเวีย
    ไนจีเรีย
    มองโกเลีย
    ลิทัวเนีย
    ไนเจอร์
    มาเลเซีย
    สเปน
    บอตสวานา
    เยเมน
    สฟาลบาร์และยานไมเอน
    บุรุนดี
    ลาว
    สโลวาเกีย
    บูร์กินาฟาโซ
    เลบานอน
    สโลวีเนีย
    เบนิน
    เวียดนาม
    สวิตเซอร์แลนด์
    มอริเตเนีย
    ศรีลังกา
    สวีเดน
    มาดากัสการ์
    สหรัฐอาหรับเอมิเรตส์
    สหราชอาณาจักร
    มาลาวี
    อัฟกานิสถาน
    ออสเตรีย
    มาลี
    อาเซอร์ไบจาน
    อิตาลี
    โมซัมบิก
    อาร์เมเนีย
    เอสโตเนีย
    โมร็อกโก
    อินเดีย
    แอลเบเนีย
    ยูกันดา
    อินโดนีเซีย
    ไอซ์แลนด์
    รวันดา
    อิรัก
    ไอร์แลนด์
    รัฐเอริเทรีย
    อิสราเอล
    ฮังการี
    ลิเบีย
    อิหร่าน
    เลโซโท
    อุซเบกิสถาน
    ไลบีเรีย
    โอมาน
    สาธารณรัฐอิเควทอเรียลกินี
    สาธารณรัฐแอฟริกากลาง
    อียิปต์
    เอธิโอเปีย
    เอสวาตีนี
    แองโกลา
    แอฟริกาใต้
    แอลจีเรีย