Infrared Vacuum System, Model VS

Infrared Vacuum System, Model VS

The Premier Vacuum Series takes full advantage of the performance synergies that only an engineered system can provide. Unlike other “systems” which merely connect multiple unitary style heaters, this maximum design flexibility ensures that all the performance and energy savings requirements of the application can be realized.
Designs are further enhanced by a full complement of additional features, including diverse tubing materials, reflector shielding configurations, multiple vacuum pump sizes, and advanced control options.

  • Custom engineered to precisely fit your building heat requirements.
  • Vacuum vented for maximum safety and operating efficiency.
  • Burner rates from 60,000 to 250,000 BTU/H can fill any heating need.
  • Up to 1.2 million BTUs on a single vacuum pump with single building penetration.
  • Additional fuel economy of at least 5%.
  • Unique, patented burner design results in - precise firing rates, reduced noxious emissions, shorter tailpipe requirements, more burners in series.
  • Reflectors of superior design and performance with side, bottom, and tilted shield options.
  • Run indicator light.
  • Couplings that outperform all others.
  • Burner housing with no loose service doors.
  • Filters are easily changed even with outside combustion air fitted.
  • Vacuum pumps are corrosion resistant, heavy-duty construction with several sizes available to best match the system.
  • Decorative grills can be installed as an option.
  • Warranty - 1 year for the control panel, 3 years for parts, 10 years for burner head. (For more info; please refer to specs and manual).
  • Patented Technology (US Patent #5,842,854).


Specifikation
  • Low-Intensity infrared Premier Vacuum System VS or VS-VH high efficiency condensing or mid-efficiency non-condensing featuring positioned tuned in-line burners to guarantee the best system efficiency in the industry. Firing rates shall be within the range of 20 MBH to 250 MBH (Model VS shall be 80,000 BTU/HR to 250,000 BTU/HR and Model VS-VH Shall be 20,000 BTU/HR to 120,000 BTU/HR). Burners shall be position-tuned and shall be factory designed to operate in a specific in-line position in the radiant branch to ensure equal firing rates for each burner in the branch. Except for the first burner, subsequent burners in a leg shall have firing rates within +/- 2% of each other. Radiant branches shall contain up to 4 burners in-line on a single branch and must be capable of modulating from 60% to 100% of normal firing rates. Minimum end vent flow rates based on design may not exceed the design provided. End vent flow rates of 200% or more will not be permitted. Assemblies shall be CSA approved to the latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a negative pressure burner system where exhaust gases and other products of combustion are routed through the blower.   The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.0 inches W.C. (propane – VS Burners only) and draw no more than 0.2 Amp at 120VAC, 60Hz. Burner head and mounting body shall be cast iron and burner controls shall allow service and diagnostic control checks with the burner operating. Reflector shall have a minimum 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with fewer than 10 surfaces will not be allowed as they allow energy to bounce back to the main heat exchanger tubing. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing and shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall allow fastening of the burner via dual U clamps to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project. 

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Professional Engineer design showing end vent airflow entry rate as equal as or less than design. 
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with an alternate system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model.
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Teknisk specifikation
  • Unik ref.vs
  • ProduktfamiljPremier Vacuum Series
  • ProduktgruppPremier VS
  • TypObjekt (enstaka objekt)
  • Publiceringsdatum2021-02-16
  • Edition nummer1
Relaterad
  • HuvudmaterialStål
  • Sekundärt materialAluminium
  • Designad iKanada
  • Tillverkad iKanada
Klassificering
  • BIMobjektkategoriVVS - Värmeapparater
  • IFC klassificeringByggnadsuppvärmare
  • UNSPSC namnSpace heaters
  • UNSPSC kod40101819
  • Uniclass 2015 kodPr_70_60_36_72
  • Uniclass 2015 beskrivningRadiant tube heaters
  • CSI MasterFormat 2014 Kod23 55 23
  • CSI MasterFormat 2014 TitelGas-Fired Radiant Heaters
  • OmniClass nummer23-33 15 17 13
  • OmniClass TitelFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II KodD30
  • CSI UniFormat II TitelHVAC

Region tillgänglighet

Europa Nordamerika Asien
Åland
Amerikanska Jungruöarna
Armenien
Albanien
Anguilla
Azerbajdzjan
Andorra
Antigua och Barbuda
Bangladesh
Belgien
Aruba
Bhutan
Bosnien och Hercegovina
Bahamas
Brittiska territoriet i Indiska oceanen
Bulgarien
Barbados
Brunei
Cypern
Belize
Filippinerna
Danmark
Bermuda
Georgia
Estland
British Virgin Islands
Hongkong
Färöarna
Caymanöarna
Indien
Finland
Costa Rica
Indonesien
Frankrike
Curaçao
Japan
Gibraltar
Dominica
Julöarna
Grekland
Dominikanska republiken
Kambodja
Guernsey
El Salvador
Kazakstan
Irland
Grenada
Kina
Island
Grönland
Kokosöarna
Isle of Man
Guadeloupe
Kyrgyzstan
Italien
Guatemala
Laos
Jersey
Haiti
Macao
Kroatien
Honduras
Malaysia
Lettland
Jamaica
Maldiverna
Liechtenstein
Kanada
Mongoliet
Litauen
Karibiska Nederländerna
Myanmar (Burma)
Luxemburg
Kuba
Nepal
Malta
Martinique
Nordkorea
Moldavien
Mexiko
Pakistan
Monaco
Montserrat
Singapore
Montenegro
Nicaragua
Sri Lanka
Nederländerna
Panama
Sydkorea
Nordmakedonien
Puerto Rico
Tadzjikistan
Norge
Saint Christopher och Nevis
Taiwan
Österrike
Saint Lucia
Thailand
Polen
Saint Vincent och Grenadinerna
Turkmenistan
Portugal
Saint-Barthélemy
Uzbekistan
Rumänien
Saint-Martin
Vietnam
Ryssland
Saint-Pierre-et-Miquelon
San Marino
Sint Maarten
Schweiz
Trinidad och Tobago
Serbien
Turks och Caicos Islands
Slovakien
USA
Slovenien
Spanien
Storbritannien
Svalbard
Sverige
Tjeckien
Tyskland
Ukraina
Ungern
Vatikanstaten
Vitryssland