Two Stage Infrared Heater, Model TX

Two Stage Infrared Heater, Model TX

Model TX - Enclosed burner design further enhancing all of the great features of the TA for hard service applications.

  • TX features a totally enclosed burner construction
  • Two stage heater – dual output for improved rate differential
  • 40,000 to 220,000 btu/h
  • Natural Gas or LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated controls compartment – electronics out of air stream, burner can run during servicing
  • Self diagnostic ignition module
  • Parabolic aluminum reflectors – Most efficient in industry
  • Direct spark ignition
  • Vented or unvented
  • Jet Stream burner – improved heat distribution, better combustion
  • Heavy duty couplings – no leaks, cannot be over tightened
  • Operating status lights
  • Low voltage controls
  • Three year warranty on all components
  • Five year warranty on hot rolled heat exchanger
  • Seven year warranty on aluminized heat exchanger
  • 10 year warranty on aluminized heat exchanger with post purge feature
Specifikation
  • Low-Intensity Two Stage Infrared Tube Heaters. Heavy-duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents within the range of 40/30 MBH to 220/165 MBH with a minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. The product shall be (please select model for unique specification) Model TA (sealed blower design), Model TX (enclosed burner design), or Model TXR (enclosed, moisture sealed burner design for rugged, harsh environments or outdoor use) as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks shall be possible with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors shall have a minimum of 10 reflective surfaces.  Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing, and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution most include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model. 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Teknisk specifikation
  • Unik ref.tx
  • ProduktfamiljTwo Stage Infrared Heaters
  • ProduktgruppLow Intensity - Series T
  • TypObjekt (enstaka objekt)
  • Publiceringsdatum2021-02-16
  • Edition nummer1
Relaterad
  • HuvudmaterialStål
  • Sekundärt materialAluminium
  • Designad iKanada
  • Tillverkad iKanada
Klassificering
  • BIMobjektkategoriVVS - Värmeapparater
  • UNSPSC namnTubular heaters
  • UNSPSC kod40101822
  • Uniclass 2015 kodPr_70_60_36_72
  • Uniclass 2015 beskrivningRadiant tube heaters
  • CSI MasterFormat 2014 Kod23 55 23
  • CSI MasterFormat 2014 TitelGas-Fired Radiant Heaters
  • OmniClass nummer23-33 15 17 13
  • OmniClass TitelFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II KodD30
  • CSI UniFormat II TitelHVAC

Region tillgänglighet

Europa Nordamerika Asien
Åland
Amerikanska Jungruöarna
Armenien
Albanien
Anguilla
Azerbajdzjan
Andorra
Antigua och Barbuda
Bangladesh
Belgien
Aruba
Bhutan
Bosnien och Hercegovina
Bahamas
Brittiska territoriet i Indiska oceanen
Bulgarien
Barbados
Brunei
Cypern
Belize
Filippinerna
Danmark
Bermuda
Georgia
Estland
British Virgin Islands
Hongkong
Färöarna
Caymanöarna
Indien
Finland
Costa Rica
Indonesien
Frankrike
Curaçao
Japan
Gibraltar
Dominica
Julöarna
Grekland
Dominikanska republiken
Kambodja
Guernsey
El Salvador
Kazakstan
Irland
Grenada
Kina
Island
Grönland
Kokosöarna
Isle of Man
Guadeloupe
Kyrgyzstan
Italien
Guatemala
Laos
Jersey
Haiti
Macao
Kroatien
Honduras
Malaysia
Lettland
Jamaica
Maldiverna
Liechtenstein
Kanada
Mongoliet
Litauen
Karibiska Nederländerna
Myanmar (Burma)
Luxemburg
Kuba
Nepal
Malta
Martinique
Nordkorea
Moldavien
Mexiko
Pakistan
Monaco
Montserrat
Singapore
Montenegro
Nicaragua
Sri Lanka
Nederländerna
Panama
Sydkorea
Nordmakedonien
Puerto Rico
Tadzjikistan
Norge
Saint Christopher och Nevis
Taiwan
Österrike
Saint Lucia
Thailand
Polen
Saint Vincent och Grenadinerna
Turkmenistan
Portugal
Saint-Barthélemy
Uzbekistan
Rumänien
Saint-Martin
Vietnam
Ryssland
Saint-Pierre-et-Miquelon
San Marino
Sint Maarten
Schweiz
Trinidad och Tobago
Serbien
Turks och Caicos Islands
Slovakien
USA
Slovenien
Spanien
Storbritannien
Svalbard
Sverige
Tjeckien
Tyskland
Ukraina
Ungern
Vatikanstaten
Vitryssland