Negative Pressure Infrared Heater - Series TVX

Negative Pressure Infrared Heater - Series TVX

The Series TVX negative pressure multi-burner system was designed to use two or more radiant tube heaters in a variety of applications, these systems offer significant operating benefits that are not easily obtainable with traditional infrared tube heaters.

Flexible layouts (Herringbone, Fork, "T", Flag, etc.) can be adapted to fit a wide range of applications heating and space requirements. Available input rates 60 / 80 / 100 / 125 / 150 / 175 / 205 / 220 MBH all featuring a two-stage configuration.

Features

  •   Input rates 60 to 220 MBH
  •   Lengths –  from 20’ to 60’
  •   Two-stage for comfort control 
  •   100% efficient reflector 
  •   Sealed burner box 
  •   3 try ignition 
  •   Integral safety switch  
  •   Simple controls 
  •   Multi-zone capability
  •   State-of-the-art pump with ECM motor
  •   Up to 525 MBH on single vent penetration
  •   Easy setup and commissioning 
  •   Standard gas flex and shut off valve are used
  •   Installation benefits – fewer vents needed
  •   Optional Equipment:
    • Elbows, Utube, outside air kit
    • Side shields, deco grille, bottom shield
Specifikation
  • Low Intensity, Two-Stage, Negative pressure Infrared Tube Heating System - Heavy duty industrial/commercial infrared heating system, featuring the best overall radiant performance in the industry. Firing rates as called for in the Contract documents within the range of 60/45 MBH to 220/165 MBH. 100% efficient reflector design with minimum 65% radiant factor as determined by independent lab testing to EN416 Standard. Baffles required as per manufacturer’s instructions. Product shall be Custom-designed, Negative Pressure, Low-Intensity Infrared Heating System: Model TVX as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks to be conducted with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish design with emitter tubes fully recessed within reflector. Reflectors shall have a minimum of 10 reflective surfaces. Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024-inch thickness aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall always extend below the lowest position of the tubing and include standard end caps. Reflector end caps: Shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4-inch (102 mm) diameter, minimum 16-gauge thickness, hot rolled steel, heat-treated type 1 aluminized steel or type 409 stainless steel materials. Heat Uniformity: Burner shall distribute hot gases along the length of the emitter tubes. Combustion Tube shall be 4 inches (102 mm) diameter, 16-gauge, heat-treated type 1 aluminized steel tubing for all firing rates. Hot rolled steel shall not be allowed. The combustion tube shall incorporate a continuously welded, 11-gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16-gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands. Exhaust pump motor shall be totally enclosed requiring no oiling and shall be equipped with overcurrent protection. It shall be one of A. For systems up to 250,000 BTU/Hr - Permanent Split Capacitor (PSC) type, Electrical supply: 120V, 60Hz, 1 PH, 1 A.B. For systems up to 525,000 BTU/Hr - Electrically Commutated Motor (ECM) Electrical supply 120V, 60Hz, 1 PH, 5 A. This product was specified based on best practice design to meet the specific engineering design criteria for this project. No Substitution Permitted. Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:- Independent lab testing to EN416 standard dated no later than 6 months from date of submission showing minimum 65% radiant factor.- Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.- Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model - Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).

Teknisk specifikation
  • Unik ref.tvx
  • ProduktfamiljNegative Pressure Systems
  • ProduktgruppSeries TVX
  • TypObjekt (enstaka objekt)
  • Publiceringsdatum2021-02-16
  • Edition nummer1
Relaterad
  • HuvudmaterialStål
  • Sekundärt materialAluminium
  • Designad iKanada
  • Tillverkad iKanada
Klassificering
  • BIMobjektkategoriVVS - Värmeapparater
  • IFC klassificeringByggnadsuppvärmare
  • UNSPSC namnSpace heaters
  • UNSPSC kod40101819
  • Uniclass 2015 kodPr_70_60_36_72
  • Uniclass 2015 beskrivningRadiant tube heaters
  • CSI MasterFormat 2014 Kod23 55 23
  • CSI MasterFormat 2014 TitelGas-Fired Radiant Heaters
  • OmniClass nummer23-33 15 17 13
  • OmniClass TitelFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II KodD30
  • CSI UniFormat II TitelHVAC

Region tillgänglighet

Europa Nordamerika Asien
Åland
Amerikanska Jungruöarna
Armenien
Albanien
Anguilla
Azerbajdzjan
Andorra
Antigua och Barbuda
Bangladesh
Belgien
Aruba
Bhutan
Bosnien och Hercegovina
Bahamas
Brittiska territoriet i Indiska oceanen
Bulgarien
Barbados
Brunei
Cypern
Belize
Filippinerna
Danmark
Bermuda
Georgia
Estland
British Virgin Islands
Hongkong
Färöarna
Caymanöarna
Indien
Finland
Costa Rica
Indonesien
Frankrike
Curaçao
Japan
Gibraltar
Dominica
Julöarna
Grekland
Dominikanska republiken
Kambodja
Guernsey
El Salvador
Kazakstan
Irland
Grenada
Kina
Island
Grönland
Kokosöarna
Isle of Man
Guadeloupe
Kyrgyzstan
Italien
Guatemala
Laos
Jersey
Haiti
Macao
Kroatien
Honduras
Malaysia
Lettland
Jamaica
Maldiverna
Liechtenstein
Kanada
Mongoliet
Litauen
Karibiska Nederländerna
Myanmar (Burma)
Luxemburg
Kuba
Nepal
Malta
Martinique
Nordkorea
Moldavien
Mexiko
Pakistan
Monaco
Montserrat
Singapore
Montenegro
Nicaragua
Sri Lanka
Nederländerna
Panama
Sydkorea
Nordmakedonien
Puerto Rico
Tadzjikistan
Norge
Saint Christopher och Nevis
Taiwan
Österrike
Saint Lucia
Thailand
Polen
Saint Vincent och Grenadinerna
Turkmenistan
Portugal
Saint-Barthélemy
Uzbekistan
Rumänien
Saint-Martin
Vietnam
Ryssland
Saint-Pierre-et-Miquelon
San Marino
Sint Maarten
Schweiz
Trinidad och Tobago
Serbien
Turks och Caicos Islands
Slovakien
USA
Slovenien
Spanien
Storbritannien
Svalbard
Sverige
Tjeckien
Tyskland
Ukraina
Ungern
Vatikanstaten
Vitryssland