Lead Free* Double Check Valve Assemblies - Small Diameter - LF850 Small, LF850U Small
Lead Free* Double Check Valve Assemblies - Small Diameter - LF850 Small, LF850U Small
    Febco

    Lead Free* Double Check Valve Assemblies - Small Diameter - LF850 Small, LF850U Small

    Series LF850 Small double check valve assembly backflow preventers includes a freeze sensor for use with SentryPlus Alert® technology to signal when temperature nears the freezing point. Activated by an add-on connection kit, the sensor triggers alerts to help facility personnel reduce equipment damage and repair that may result from cold weather conditions. Available for building and irrigation management systems.

    This series is designed to prevent the backflow of polluted water from entering the potable water supply due to backsiphonage and or backpressure. Features lead free body construction, NPT end connections, top mounted test cocks, and quarter turn ball valve shutoffs.

    Specifikation
    • Features

      • Sensor signals to indicate when temperature nears the freezing point once activated by an add-on BMS/IMS connection kit
      • Compact modular design to facilitate maintenance and in-line repairs with a single access cover
      • In-line serviceable assembly requiring no special tools
      • Two in-line independent positive seating check modules
      • Replaceable seats and seat discs


      Outlet Connection Size

      • 1/2 IN
      • 3/4 IN
      • 1 IN
      • 1 1/4 IN
      • 1 1/2 IN
      • 2 IN

      Inlet Connection Type

      • Female Threaded
      • Union Joint

      Inlet Connection Size

      • 1/2 IN
      • 3/4 IN
      • 1 IN
      • 1 1/4 IN
      • 1 1/2 IN
      • 2 IN


    Teknisk specifikation
    • Unik ref.lf850-lf850U-small
    • ProduktfamiljBackflow Prevention
    • ProduktgruppDouble Check Valve Assemblies
    • TypObjekt (enstaka objekt)
    • Publiceringsdatum2019-12-03
    • Edition nummer1
    Relaterad
    • HuvudmaterialCast iron
    • Designad iUSA
    • Tillverkad iUSA
    Klassificering
    • BIMobjektkategoriRörläggning - Ventiler
    • IFC klassificeringVentil
    • UNSPSC namnValves
    • UNSPSC kod401416
    • Uniclass 2015 kodPr_65_54_95_05
    • Uniclass 2015 beskrivningBackflow prevention devices
    • CSI MasterFormat 2014 Kod40 05 67.13
    • CSI MasterFormat 2014 TitelReduced-Pressure Zone Backflow Preventers for Process Service
    • OmniClass nummer23-27 31 11
    • OmniClass TitelBackflow Preventors
    • CSI UniFormat II KodD20
    • CSI UniFormat II TitelPLUMBING

    Region tillgänglighet

    Nordamerika
    Kanada
    USA