Two Stage Infrared Heater, Model TX

Two Stage Infrared Heater, Model TX

Model TX - Enclosed burner design further enhancing all of the great features of the TA for hard service applications.

  • TX features a totally enclosed burner construction
  • Two stage heater – dual output for improved rate differential
  • 40,000 to 220,000 btu/h
  • Natural Gas or LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated controls compartment – electronics out of air stream, burner can run during servicing
  • Self diagnostic ignition module
  • Parabolic aluminum reflectors – Most efficient in industry
  • Direct spark ignition
  • Vented or unvented
  • Jet Stream burner – improved heat distribution, better combustion
  • Heavy duty couplings – no leaks, cannot be over tightened
  • Operating status lights
  • Low voltage controls
  • Three year warranty on all components
  • Five year warranty on hot rolled heat exchanger
  • Seven year warranty on aluminized heat exchanger
  • 10 year warranty on aluminized heat exchanger with post purge feature
Specifikim
  • Low-Intensity Two Stage Infrared Tube Heaters. Heavy-duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents within the range of 40/30 MBH to 220/165 MBH with a minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. The product shall be (please select model for unique specification) Model TA (sealed blower design), Model TX (enclosed burner design), or Model TXR (enclosed, moisture sealed burner design for rugged, harsh environments or outdoor use) as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks shall be possible with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors shall have a minimum of 10 reflective surfaces.  Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing, and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution most include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model. 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Specifikime teknike
  • Referencë uniketx
  • Familja e produkteveTwo Stage Infrared Heaters
  • Grupi i produkteveLow Intensity - Series T
  • LlojiObjekt (një objekt të vetëm)
  • Data e botimit2021-02-16
  • Numri i botimit1
Të ngjashme
  • Materiali kryesorÇelik
  • Materiali dytësorAlumin
  • Projektuar nëKanadë
  • Prodhuar nëKanadë
Klasifikimi
  • Kategoria BIMobjectNgrohes, ventilimit dhe ajrit të kondicionuar - Ngrohës
  • Emrin UNSPSCTubular heaters
  • UNSPSC code40101822
  • Uniclass 2015 CodePr_70_60_36_72
  • Uniclass 2015 PërshkrimRadiant tube heaters
  • CSI MasterFormat 2014 Code23 55 23
  • CSI MasterFormat 2014 TitleGas-Fired Radiant Heaters
  • OmniClass Number23-33 15 17 13
  • OmniClass TitleFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II CodeD30
  • CSI UniFormat II TitleHVAC

Rajoni i disponueshëm

Europe North America Asia
Åland Islands
Anguilla
Armeni
Andorra
Antigua dhe Barbuda
Azerbaixhan
Austri
Aruba
Bangladesh
Belgjikë
Bahamas
Brunei
Bjellorusi
Barbados
Butan
Bosnjë dhe Hercegovinë
Belize
Filipinet
Bulgari
Bermuda
Gjeorgji
Danimarkë
Dominica
Hong Kong
Estoni
El Salvador
Indi
Finlandë
Grenada
Indonezi
Francë
Grenlandë
Ishujt Cocos (Keeling)
Gërnzi
Guadeloupe
Japoni
Gjermani
Guatemala
Kamboxhi
Gjibraltar
Haiti
Kazahstan
Greqi
Honduras
Kinë
Holandë
Ishujt e Virgjër Britanikë
Kirgistan
Hungari
Ishujt e Virgjër të SHBA
Korea e jugut
Irlandë
Ishujt Kajman
Korea e Veriut
Ishujt Faroe
Kanadë
Krishtlindje Island
Ishulli i Njeriut
Karaibe Holandë
Laos
Islandë
Kolektiviteti i Shën Martinit
Macau
Itali
Kosta Rika
Malazi
Jersey
Kubë
Maldives
Kroacia
Kuraçao
Mongoli
Letoni
Martinique
Myanmar (Burma)
Liechtenstein
Meksikë
Neoal
Lituani
Montserrat
Pakistan
Luksemburg
Nikaragua
Singapore
Mali i Zi
Panama
Sri Lanka
Maltë
Porto Riko
Taiwan
Maqedonia e Veriut
Republika Domenikane
Tajlandë
Mbretëria e Bashkuar
Saint-Barthélemy
Taxhikistan
Moldovë
Shën Kitts dhe Nevis
Territori Britanik i Oqeanit Indian
Monaco
Shën Lucia
Turkmenistan
Norvegji
Shën Pierre dhe Miquelon
Uzbekistan
Poloni
Shën Vincent dhe Grenadinet
Vietnam
Portugali
Shtetet e Bashkuara
Qipro
Sint Maarten
Qyteti i Vatikanit
Trinidad dhe Tobago
Republika Çeke
Turks dhe Caicos Islands
Rumani
Xhamaika
Rusi
San Marino
Serbia
Shqipëri
Sllovenia
Slovakia
Spanjë
Suedi
Svalbard dhe Jan Mayen
Switzerland
Ukrainë