    PROTAN PROTECTED WARM ROOF SYSTEM ON CONCRETE SUBSTRATE

    The roof is built up on the load-bearing structure with the vapour control layer at the bottom, followed by insulation, Protan membrane and then the ballast on top. The ballast is often pebbles,paving slabs or intensive green roofs. The fall requirements for the construction can be incorporated into the deck substrate or the insulation under the membrane.

    A ballasted roof with paving slabs is suitable for situations where foot traffic is expected, such as terraced areas for recreational use or frequent service access. Such roofs are used for both heavy load-bearing structures made of concrete and light load-bearing structures made of sheet steel. The composition principle is the same for both solutions. The heavy structure may be most suited to premises with a high moisture content, for example, while the light structure may be most suited to warehouses and the like. Pebbles may be used as ballast where the foot traffic is limited to minimal maintenance and inspection access only.

    For roof structures that are exposed to extra heavy loads, Protan GG Membrane is recommended.

    .CONSTRUCTION STRUCTURE:

    • PROTECTED WITH GRAVEL- /INVERTED- /INTENSIVE GREEN ROOFS
    • PROTAN G / GG MEMBRANE
    • INSULATION
    • VAPOUR CONTROL LAYER
    • CONCRETE SUBSTRATE

    PROTAN G / GGMEMBRANE

    • Protan G membrane is a glass fibre reinforced, microbe durable PVC membrane for gravel ballasted roofs, inverted roofs, and green roofs. 
    • Protan G membrane can withstand high and low temperatures and attack by micro-organisms. 
    • The membrane is dimensionally stable, which is important in load-bearing applications, inverted roofs, and green roofs. 
    • Protan G membrane can withstand high and low temperatures and attack by micro-organisms.
    • The membrane is welded together using hot air.

    SYSTEM INSTALLATION METHOD:

    • Protan G membrane is installed as a loose layer without fasteners securing it to the substrate. Protection layers are required where there is a risk of damage by the layers installed over the membrane.

    INSULATION:

    Various types of insulation can be used in combination with Protan membranes and can be flat insulation or sloped insulation. The material type and design will depend on the building design, fire classification and local regulation requirements. The compression strength of the insulation must be considered and chosen to according to the roof application.

    • Mineral wool (MW) – can be glass or stone type
    • Expanded polystyrene (EPS) - a glass separation layer / migration barrier must be used
    • Polyisocyanurate (PIR) - foil faced
    • Combination EPS-MW

    VAPOUR CONTROL LAYER:

    • Polyethylene
    • Bitumen

    CONCRETE SUBSTRATE:

    • Structural concrete as either precast elements or reinforced cast in-situ.


    Specifikim
    • TECHNICAL SPECIFICATION

      Protan G specifications are subject to availability and may not be available or approved in all countries/regions.

      Membrane thickness:

      • 1.5 mm

      Membrane standard widths: 

      • 2.0 m 

      Membrane standard roll lengths: 

      • 7.5 m 
      • 15

      Membrane colours (nearest RAL code):

      • Dark grey F94 - RAL 7012 
      • Light grey F91- RAL 7040

      FIRE CLASSIFICATION

      Protan G has no fire classification.



    Specifikime teknike
    • Referencë unikeprotected_concrete_eu
    • Familja e produkteveRoofing
    • Grupi i produkteveSingle Ply Membrane
    • LlojiObjekt (një objekt të vetëm)
    • Data e botimit2019-02-19
    • Numri i botimit1
    Të ngjashme
    • Materiali kryesorPVC
    • Materiali dytësorInsulation
    • Projektuar nëNorvegji
    • Prodhuar nëNorvegji
    Klasifikimi
    • Kategoria BIMobjectMateriale ndërtimi - Hidroizolues & Membrane
    • IFC classificationKulmet
    • Emrin UNSPSCRoofing membranes
    • UNSPSC code30151505
    • Uniclass 2015 CodeSs_30_40_30_80
    • Uniclass 2015 PërshkrimSingle layer sheet warm roof covering systems
    • CSI MasterFormat 2014 Code07 50 00
    • CSI MasterFormat 2014 TitleMembrane Roofing
    • OmniClass Number23-13 39 31 11 27
    • OmniClass TitlePolyvinyl chloride (PVC) Single Layer Roof Membranes
    • CSI UniFormat II CodeB3010
    • CSI UniFormat II TitleRoof Coverings

    Rajoni i disponueshëm

    Europe Asia
    Åland Islands
    Turqi
    Andorra
    Austri
    Belgjikë
    Bjellorusi
    Bosnjë dhe Hercegovinë
    Bulgari
    Danimarkë
    Estoni
    Finlandë
    Francë
    Gërnzi
    Gjermani
    Gjibraltar
    Greqi
    Holandë
    Hungari
    Irlandë
    Ishujt Faroe
    Ishulli i Njeriut
    Islandë
    Itali
    Jersey
    Kroacia
    Letoni
    Liechtenstein
    Lituani
    Luksemburg
    Mali i Zi
    Maltë
    Maqedonia e Veriut
    Mbretëria e Bashkuar
    Moldovë
    Monaco
    Norvegji
    Poloni
    Portugali
    Qipro
    Qyteti i Vatikanit
    Republika Çeke
    Rumani
    Rusi
    San Marino
    Serbia
    Shqipëri
    Sllovenia
    Slovakia
    Spanjë
    Suedi
    Svalbard dhe Jan Mayen
    Switzerland
    Ukrainë