The sensing cable is formed from a pair of twisted steel conductors each with temperature sensitive insulation and then an overall outer sleeve. When the temperature sensitive insulation reaches its predetermined alarm temperature the two conductors short together providing the alarm signal. The cable can be connected to any unit capable of monitoring a switched or digital alarm signal (i.e. conventional fire panel, addressable switch monitor unit or PLC). The fire detection capability can be enhanced when the LHD is used in conjunction with the Digital Location Interface (DU).

LHD cable is classified as a "simple device" and so with the use of suitable Intrinsically Safe (IS) barriers to limit the energy to a safe level, it can be used in hazardous areas. The Linear Heat Detection cable can be cut to length as required and with its ease of installation and low maintenance it provides a cost effective solution where project expenditure requires to be kept at a minimum. The Linesense Linear Heat Detection cable has the widest range of Alarm temperatures 68°C to 240°C.

Features

  • Simple digital switch operation
  • Continuous sensing along the total length of the element
  • Fixed alarm temperature. Unaffected by changes in ambient temperature
  • Compatible with switch monitoring units and conventional alarm panels
  • Suitable for use in Hazardous areas using safety barriers
  • UV resistant PVC outer sleeve
  • Rugged and durable construction
  • Simple maintenance free installation
  • Small diameter and bend radius
  • FM Approved
Specifikime teknike
  • Referencë unikedlm-z2_controller-and-linear-heat-detection-cable
  • Familja e produkteveFire Protection Products
  • Grupi i produkteveLinear Heat Detection
  • LlojiObjekt (një objekt të vetëm)
  • Data e botimit2023-10-23
  • Numri i botimit1
Të ngjashme
  • Projektuar nëShtetet e Bashkuara
  • Prodhuar nëShtetet e Bashkuara
Klasifikimi
  • Kategoria BIMobjectAparateve kundër zjarrit - Mbrojtje
  • IFC classificationAlarm
  • Kodi ETIMEC001763
  • Emri ETIMFire detector
  • Uniclass 2015 CodeSs_75_50_28_29
  • Uniclass 2015 PërshkrimFire detection and alarm systems
  • CSI MasterFormat 2014 Code28 31 00
  • CSI MasterFormat 2014 TitleFire Detection and Alarm
  • OmniClass Number23-29 29 00
  • OmniClass TitleFire Detection Devices

Rajoni i disponueshëm

North America
Anguilla
Antigua dhe Barbuda
Aruba
Bahamas
Barbados
Belize
Bermuda
Dominica
El Salvador
Grenada
Grenlandë
Guadeloupe
Guatemala
Haiti
Honduras
Ishujt e Virgjër Britanikë
Ishujt e Virgjër të SHBA
Ishujt Kajman
Kanadë
Karaibe Holandë
Kolektiviteti i Shën Martinit
Kosta Rika
Kubë
Kuraçao
Martinique
Meksikë
Montserrat
Nikaragua
Panama
Porto Riko
Republika Domenikane
Saint-Barthélemy
Shën Kitts dhe Nevis
Shën Lucia
Shën Pierre dhe Miquelon
Shën Vincent dhe Grenadinet
Shtetet e Bashkuara
Sint Maarten
Trinidad dhe Tobago
Turks dhe Caicos Islands
Xhamaika