Rectangular ventilation ducts system

Rectangular ventilation ducts system

3.1 out of 5 stars3.1(9 reviews)
  • Rectangular ventilation ducts and fittings are intended for air distribution in ventilation and air-conditioning systems in buildings, including residential buildings, collective residence and public utility buildings. They can also be used in warehouse, industrial and farm buildings.
    Straight lines and fittings may be used under the following conditions:
    - temperature of transported air in the range from -30 °C to + 70 °C,
    - relative humidity of transported air up to 100%,
    - air transport without chemically aggressive and abrasive factors,
    - air flow speed up to 16 m/s,
    - static air pressure difference inside and outside the duct from -500 Pa to 1000 Pa (execution class N, according to WO-KOT / 36/01 revision 2).
  • Due to the requirements for corrosion resistance, Rectangular ventilation ducts and fittings made of galvanized steel sheet, grade DX51D + Z275 according to PN-EN 10346:2015 standard, are characterized by high durability and can be used in corrosive environments. C1, C2 and C3 atmospheres according to PN-EN ISO 92232012.
    The connecting elements should be protected against corrosion in a manner appropriate to the corrosion resistance of the pipes.
  • Rectangular ventilation ducts and fittings have been classified in class A1, d0 reaction to fire according to PN-EN 13501-1:2019 and as non-flammable, non-drip and non-spreading fire inside buildings according to the decision of the Minister of Infrastructure of 12 April 2002 (Journal of Laws No. 75 of April 12, 2002, item 690, as amended). At the same time, the products are classified as fire resistant.
Specifikim
  • Dimensions: 100- 4000 mm

    Minimum area of fitting to calculate is 1,0 m 2.

    Standard length of ducts-1500 mm.

    Basic characteristics:

    Duct tightness - class A or B  (Assessment method PN-EN 1507:2007 i WO-KOT/36/01 wydanie 2)

    Durability (elements made of galvanized steel sheet):
    - weight of the zinc coating, g/m2≥ 275
    - thickness of the zinc coating, pm 20 (tolerance acc. to PN-EN 10346)

    Deformation: No permanent deformation or sudden change of tightness at the limit values of static pressure

Specifikime teknike
  • Referencë unikerectangular-ventilation-duct-system
  • Familja e produkteveVentilation ducts
  • Grupi i produkteveVentilation ducts of galvanized steel Airwent System
  • LlojiMaterial për ndërtim
  • Data e botimit2023-10-26
  • Numri i botimit1
Të ngjashme
  • Materiali kryesorGalvanized steel
  • Projektuar nëPoloni
  • Prodhuar nëPoloni
Klasifikimi
  • Kategoria BIMobjectNgrohes, ventilimit dhe ajrit të kondicionuar - Gyp
  • IFC classificationSegmenti i kanaleve
  • Kodi ETIMEC000059
  • Emri ETIMInstallation duct
  • Uniclass 2015 CodePr_20_85_12
  • Uniclass 2015 PërshkrimBunds and ducts
  • CSI MasterFormat 2014 Code23 31 00
  • CSI MasterFormat 2014 TitleHVAC Ducts and Casings
  • OmniClass Number23-33 49 00
  • OmniClass TitleHVAC Ductwork

Rajoni i disponueshëm

Europe
Åland Islands
Andorra
Austri
Belgjikë
Bjellorusi
Bosnjë dhe Hercegovinë
Bulgari
Danimarkë
Estoni
Finlandë
Francë
Gërnzi
Gjermani
Gjibraltar
Greqi
Holandë
Hungari
Irlandë
Ishujt Faroe
Ishulli i Njeriut
Islandë
Itali
Jersey
Kroacia
Letoni
Liechtenstein
Lituani
Luksemburg
Mali i Zi
Maltë
Maqedonia e Veriut
Mbretëria e Bashkuar
Moldovë
Monaco
Norvegji
Poloni
Portugali
Qipro
Qyteti i Vatikanit
Republika Çeke
Rumani
Rusi
San Marino
Serbia
Shqipëri
Sllovenia
Slovakia
Spanjë
Suedi
Svalbard dhe Jan Mayen
Switzerland
Ukrainë