Опубликуйте свои продукты
Infrared Vacuum System, Model VS
Superior Radiant Products

Infrared Vacuum System, Model VS

The Premier Vacuum Series takes full advantage of the performance synergies that only an engineered system can provide. Unlike other “systems” which merely connect multiple unitary style heaters, this maximum design flexibility ensures that all the performance and energy savings requirements of the application can be realized.
Designs are further enhanced by a full complement of additional features, including diverse tubing materials, reflector shielding configurations, multiple vacuum pump sizes, and advanced control options.

  • Custom engineered to precisely fit your building heat requirements.
  • Vacuum vented for maximum safety and operating efficiency.
  • Burner rates from 60,000 to 250,000 BTU/H can fill any heating need.
  • Up to 1.2 million BTUs on a single vacuum pump with single building penetration.
  • Additional fuel economy of at least 5%.
  • Unique, patented burner design results in - precise firing rates, reduced noxious emissions, shorter tailpipe requirements, more burners in series.
  • Reflectors of superior design and performance with side, bottom, and tilted shield options.
  • Run indicator light.
  • Couplings that outperform all others.
  • Burner housing with no loose service doors.
  • Filters are easily changed even with outside combustion air fitted.
  • Vacuum pumps are corrosion resistant, heavy-duty construction with several sizes available to best match the system.
  • Decorative grills can be installed as an option.
  • Warranty - 1 year for the control panel, 3 years for parts, 10 years for burner head. (For more info; please refer to specs and manual).
  • Patented Technology (US Patent #5,842,854).


Cпецификация
  • Low-Intensity infrared Premier Vacuum System VS or VS-VH high efficiency condensing or mid-efficiency non-condensing featuring positioned tuned in-line burners to guarantee the best system efficiency in the industry. Firing rates shall be within the range of 20 MBH to 250 MBH (Model VS shall be 80,000 BTU/HR to 250,000 BTU/HR and Model VS-VH Shall be 20,000 BTU/HR to 120,000 BTU/HR). Burners shall be position-tuned and shall be factory designed to operate in a specific in-line position in the radiant branch to ensure equal firing rates for each burner in the branch. Except for the first burner, subsequent burners in a leg shall have firing rates within +/- 2% of each other. Radiant branches shall contain up to 4 burners in-line on a single branch and must be capable of modulating from 60% to 100% of normal firing rates. Minimum end vent flow rates based on design may not exceed the design provided. End vent flow rates of 200% or more will not be permitted. Assemblies shall be CSA approved to the latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a negative pressure burner system where exhaust gases and other products of combustion are routed through the blower.   The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.0 inches W.C. (propane – VS Burners only) and draw no more than 0.2 Amp at 120VAC, 60Hz. Burner head and mounting body shall be cast iron and burner controls shall allow service and diagnostic control checks with the burner operating. Reflector shall have a minimum 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with fewer than 10 surfaces will not be allowed as they allow energy to bounce back to the main heat exchanger tubing. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing and shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall allow fastening of the burner via dual U clamps to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project. 

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Professional Engineer design showing end vent airflow entry rate as equal as or less than design. 
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with an alternate system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model.
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Техническая спецификация
  • Уникальная ссылкаvs
  • Тип продукцииPremier Vacuum Series
  • Группа продукцииPremier VS
  • ТипОбъект (один объект)
  • Дата публикации2021-02-16
  • Номер версии1
Ссылки
Связанные
  • Основной материалСталь
  • Вспомогательный материалАлюминий
  • Разработано вКанада
  • Страна-производительКанада
Классификация
  • Категория BIMobjectВентиляция и кондиционирование воздуха - Нагреватели
  • Классификация IFCОбогреватель
  • Название по ССКПУ ООНSpace heaters
  • Код ССКПУ ООН40101819
  • Код Uniclass 2015Pr_70_60_36_72
  • Описание Uniclass 2015Radiant tube heaters
  • Код CSI MasterFormat 201423 55 23
  • Заголовок CSI MasterFormat 2014Gas-Fired Radiant Heaters
  • Номер OmniClass23-33 15 17 13
  • Наименование OmniClassFuel Fired HVAC Radiant Heaters
  • Код CSI UniFormat IID30
  • Заголовок CSI UniFormat IIHVAC

Доступно в регионах:

Европа Северная Америка Азия
Австрия
Ангилья
Азербайджан
Аландские острова
Антигуа и Барбуда
Армения
Албания
Аруба
Бангладеш
Андорра
Багамы
Британская территория в Индийском океане
Беларусь
Барбадос
Бруней-Даруссалам
Бельгия
Белиз
Бутан
Болгария
Бермуды
Вьетнам
Босния и Герцеговина
Бонэйр
Гонконг
Великобритания
Британские Виргинские острова
Грузия
Венгрия
Виргинские Острова
Индия
Германия
Гаити
Индонезия
Гернси
Гваделупа
Казахстан
Гибралтар
Гватемала
Камбоджа
Греция
Гондурас
Киргизия
Дания
Гренада
Китай
Джерси
Гренландия
Кокосовые острова
Ирландия
Доминика
Корейская Народно-Демократическая Республика
Исландия
Доминиканская Республика
Лаос
Испания
Канада
Макао
Италия
Коста-Рика
Малайзия
Кипр
Куба
Мальдивы
Латвия
Кюрасао
Монголия
Литва
Мартиника
Мьянма (Бирма)
Лихтенштейн
Мексика
Непал
Люксембург
Монтсеррат
Остров Рождества
Мальта
Никарагуа
Пакистан
Молдова
Острова Кайман
Сингапур
Монако
Острова Теркс и Кайкос
Таджикистан
Нидерланды
Панама
Таиланд
Норвегия
Пуэрто-Рико
Тайвань
о-в Мэн
Сальвадор
Туркменистан
Папский Престол (Государство-город Ватикан)
Сен-Бартелеми
Узбекистан
Польша
Сен-Мартен
Филиппины
Португалия
Сен-Пьер и Микелон
Шри-Ланка
Россия
Сент-Винсент и Гренадины
Южная Корея
Румыния
Сент-Китс и Невис
Япония
Сан-Марино
Сент-Люсия
Северная Македония
Синт-Мартен
Сербия
Соединенные Штаты Америки
Словакия
Тринидад и Тобаго
Словения
Ямайка
Украина
Фарерские о-ва
Финляндия
Франция
Хорватия
Черногория
Чехия
Швейцария
Швеция
Шпицберген
Эстония