Single Stage Infrared Heater, Model UX
Superior Radiant Products

Single Stage Infrared Heater, Model UX

Enclosed burner design further enhances all of the great features of the UA for hard service applications. Post-purge function and optional 10 year tube warranty.

  • UX features a totally enclosed burner construction
  • 40,000 to 220,000 BTU/h
  • Natural Gas and LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated Controls compartment – electronics out of air stream, the burner can run during servicing
  • Self-diagnostic ignition module
  • Parabolic aluminum reflectors – most efficient in the industry
  • Direct spark ignition
  • Vented or unvented
  • Jet Stream burner – improved heat distribution, better combustion
  • Heavy duty couplings – no leaks, cannot be over tightened
  • Operating status light
  • Low voltage controls
  • Three-year warranty on all components
  • Five-year warranty on hot-rolled heat exchanger
  • Seven-year warranty on aluminized heat exchanger
  • 10-year warranty on the aluminized heat exchanger with post purge feature
Cпецификация
  • Low-Intensity Single Stage Infrared Tube Heaters with minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. 

    Assemblies shall be CSA approved low-intensity heater to the latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a positive pressure burner system, where exhaust gases and other products of combustion are not routed through the blower. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz.Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with less than 10 surfaces will not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project. 

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with alternate systems.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Техническая спецификация
  • Уникальная ссылкаux
  • Тип продукцииSingle Stage Infrared Heaters
  • Группа продукцииLow Intensity - Series U
  • ТипОбъект (один объект)
  • Дата публикации2021-02-16
  • Номер версии1
Связанные
  • Основной материалСталь
  • Вспомогательный материалАлюминий
  • Разработано вКанада
  • Страна-производительКанада
Классификация
  • Категория BIMobjectВентиляция и кондиционирование воздуха - Нагреватели
  • Название по ССКПУ ООНTubular heaters
  • Код ССКПУ ООН40101822
  • Код Uniclass 2015Pr_70_60_36_72
  • Описание Uniclass 2015Radiant tube heaters
  • Код CSI MasterFormat 201423 55 23
  • Заголовок CSI MasterFormat 2014Gas-Fired Radiant Heaters
  • Номер OmniClass23-33 15 17 13
  • Наименование OmniClassFuel Fired HVAC Radiant Heaters
  • Код CSI UniFormat IID30
  • Заголовок CSI UniFormat IIHVAC

Доступно в регионах:

Северная Америка
Ангилья
Антигуа и Барбуда
Аруба
Багамы
Барбадос
Белиз
Бермуды
Бонэйр
Британские Виргинские острова
Виргинские Острова
Гаити
Гваделупа
Гватемала
Гондурас
Гренада
Гренландия
Доминика
Доминиканская Республика
Канада
Коста-Рика
Куба
Кюрасао
Мартиника
Мексика
Монтсеррат
Никарагуа
Острова Кайман
Острова Теркс и Кайкос
Панама
Пуэрто-Рико
Сальвадор
Сен-Бартелеми
Сен-Мартен
Сен-Пьер и Микелон
Сент-Винсент и Гренадины
Сент-Китс и Невис
Сент-Люсия
Синт-Мартен
Соединенные Штаты Америки
Тринидад и Тобаго
Ямайка