Two Stage CNG Infrared Heater, Model LTX 750
Superior Radiant Products

Two Stage CNG Infrared Heater, Model LTX 750

The series 750 low-temperature tube heater, was designed and approved* for use in maintenance facilities where specialty fueled vehicles are repaired. The patent-pending tube system maintains tube temperatures less than 750°F while providing even heat distribution.

  • Ideal for CNG or LNG-fueled vehicle repair facilities
  • Tube temperature below 750°F
  • End-to-end output variance is less than 15%
  • Largest burner rates in industry up to 100,000 BTU/HR
  • Two stage
  • Separated controls compartment
  • External Sealed Blower
  • Self-diagnostic ignition module
  • Parabolic aluminum reflectors
  • Heavy-duty couplings

*approved and certified by CSA to meet maximum tube temperature of 750˚ F (399˚C) in accordance with NFPA 30A 7.6.6

Cпецификация
  • Low Intensity, Low Clearance, Low temperature, Even Heat Two Stage Infrared Tube Heaters.  Heavy duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents, either 60/45 MBH or 100/75 MBH. Designed for low clearance, even heat applications in specialty fueled vehicle or similar facilities that must comply with NFPA 30A 7.6.6, requiring maximum heater surface temperature of 750° F. All Series 750 units include our patented design, which provides unequalled even heat distribution with end to end output variance of less than 15%. Baffles required as per manufacturer’s instructions.

    Assemblies shall be CSA approved low intensity heater to latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications and shall also be CSA tested and certified to comply with NFPA 30A 7.6.6. Burner shall be a positive pressure burner system where exhaust gases and other products of combustion are not routed through the blower.   The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) and draw no more than 1 Amp at 120VAC, 60Hz.

    Burner head shall be chrome plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks with the burner operating. Reflector shall have a minimum 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within reflector. Reflectors with fewer than 10 surfaces will not be permitted. Reflector shall be mill finished aluminum, ASTM 1100, .024 inch thickness aluminum sheet metal with two reflector support brackets for each 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss, and shall be standard equipment. Emitter Tube shall be 4 inch (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, type 1 aluminized steel tubing and be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length and be of heavy duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing showing even distribution of hot gasses across the emitter tube with a minimum variance of less than 15%
    • Professional Engineer Stamped Design, calculations and complete set of stamped drawings with alternate system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).

     

Техническая спецификация
  • Уникальная ссылкаcng-ltx
  • Тип продукцииCNG Series 750
  • Группа продукцииTwo Stage - Model LTX
  • ТипОбъект (один объект)
  • Дата публикации2021-02-16
  • Номер версии1
Ссылки
Связанные
  • Основной материалСталь
  • Вспомогательный материалАлюминий
  • Разработано вКанада
  • Страна-производительКанада
Классификация
  • Категория BIMobjectВентиляция и кондиционирование воздуха - Нагреватели
  • Название по ССКПУ ООНTubular heaters
  • Код ССКПУ ООН40101822
  • Код Uniclass 2015Pr_70_60_36_72
  • Описание Uniclass 2015Radiant tube heaters
  • Код CSI MasterFormat 201423 55 23
  • Заголовок CSI MasterFormat 2014Gas-Fired Radiant Heaters
  • Номер OmniClass23-33 15 17 13
  • Наименование OmniClassFuel Fired HVAC Radiant Heaters
  • Код CSI UniFormat IID30
  • Заголовок CSI UniFormat IIHVAC

Доступно в регионах:

Северная Америка
Ангилья
Антигуа и Барбуда
Аруба
Багамы
Барбадос
Белиз
Бермуды
Бонэйр
Британские Виргинские острова
Виргинские Острова
Гаити
Гваделупа
Гватемала
Гондурас
Гренада
Гренландия
Доминика
Доминиканская Республика
Канада
Коста-Рика
Куба
Кюрасао
Мартиника
Мексика
Монтсеррат
Никарагуа
Острова Кайман
Острова Теркс и Кайкос
Панама
Пуэрто-Рико
Сальвадор
Сен-Бартелеми
Сен-Мартен
Сен-Пьер и Микелон
Сент-Винсент и Гренадины
Сент-Китс и Невис
Сент-Люсия
Синт-Мартен
Соединенные Штаты Америки
Тринидад и Тобаго
Ямайка