Опубликуйте свои продукты
Two Stage Infrared Heater, Model TXR
Superior Radiant Products

Two Stage Infrared Heater, Model TXR

Model TXR - As the Model TX with extra features for harsh and outdoor environments. Model TXR includes a potted module, sealed burner housing, and heat-treated aluminized. Stainless steel available.

  • Two stage heater – Approved for outdoor use
  • 40,000 to 220,000 BTU/h
  • Natural Gas or LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated controls compartment – electronics out of air stream, burner can run during servicing
  • Self diagnostic ignition module
  • Parabolic aluminum reflectors - Most efficient in industry
  • Direct spark ignition
  • Vented or unvented
  • Jet Stream burner – improved heat distribution, better combustion
  • Heavy duty couplings – no leaks, cannot be over tightened
  • Operating status lights
  • Low voltage controls
  • TXR features burner box sealed for outdoor conditions
  • Rubber gaskets are used instead of fiber
  • Silicone used to seal corners and joints
  • Weather resistant electrical components used for exterior connections
  • Stainless steel burner boxes available as well as tubing and reflectors
  • Units are wind resistant
  • Three year warranty on all components
  • Five year warranty on hot rolled heat exchanger
  • Seven year warranty on aluminized heat exchanger
  • 10 year warranty on aluminized heat exchanger with post purge feature
Cпецификация
  • Low-Intensity Two Stage Infrared Tube Heaters. Heavy-duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents within the range of 40/30 MBH to 220/165 MBH with a minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. The product shall be (please select model for unique specification) Model TA (sealed blower design), Model TX (enclosed burner design), or Model TXR (enclosed, moisture sealed burner design for rugged, harsh environments or outdoor use) as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks shall be possible with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors shall have a minimum of 10 reflective surfaces.  Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing, and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution most include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model. 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Техническая спецификация
  • Уникальная ссылкаtxr
  • Тип продукцииTwo Stage Infrared Heaters
  • Группа продукцииLow Intensity - Series T
  • ТипОбъект (один объект)
  • Дата публикации2021-02-16
  • Номер версии1
Связанные
  • Основной материалСталь
  • Вспомогательный материалАлюминий
  • Разработано вКанада
  • Страна-производительКанада
Классификация
  • Категория BIMobjectВентиляция и кондиционирование воздуха - Нагреватели
  • Название по ССКПУ ООНTubular heaters
  • Код ССКПУ ООН40101822
  • Код Uniclass 2015Pr_70_60_36_72
  • Описание Uniclass 2015Radiant tube heaters
  • Код CSI MasterFormat 201423 55 23
  • Заголовок CSI MasterFormat 2014Gas-Fired Radiant Heaters
  • Номер OmniClass23-33 15 17 13
  • Наименование OmniClassFuel Fired HVAC Radiant Heaters
  • Код CSI UniFormat IID30
  • Заголовок CSI UniFormat IIHVAC

Доступно в регионах:

Европа Северная Америка Азия
Австрия
Ангилья
Азербайджан
Аландские острова
Антигуа и Барбуда
Армения
Албания
Аруба
Бангладеш
Андорра
Багамы
Британская территория в Индийском океане
Беларусь
Барбадос
Бруней-Даруссалам
Бельгия
Белиз
Бутан
Болгария
Бермуды
Вьетнам
Босния и Герцеговина
Бонэйр
Гонконг
Великобритания
Британские Виргинские острова
Грузия
Венгрия
Виргинские Острова
Индия
Германия
Гаити
Индонезия
Гернси
Гваделупа
Казахстан
Гибралтар
Гватемала
Камбоджа
Греция
Гондурас
Киргизия
Дания
Гренада
Китай
Джерси
Гренландия
Кокосовые острова
Ирландия
Доминика
Корейская Народно-Демократическая Республика
Исландия
Доминиканская Республика
Лаос
Испания
Канада
Макао
Италия
Коста-Рика
Малайзия
Кипр
Куба
Мальдивы
Латвия
Кюрасао
Монголия
Литва
Мартиника
Мьянма (Бирма)
Лихтенштейн
Мексика
Непал
Люксембург
Монтсеррат
Остров Рождества
Мальта
Никарагуа
Пакистан
Молдова
Острова Кайман
Сингапур
Монако
Острова Теркс и Кайкос
Таджикистан
Нидерланды
Панама
Таиланд
Норвегия
Пуэрто-Рико
Тайвань
о-в Мэн
Сальвадор
Туркменистан
Папский Престол (Государство-город Ватикан)
Сен-Бартелеми
Узбекистан
Польша
Сен-Мартен
Филиппины
Португалия
Сен-Пьер и Микелон
Шри-Ланка
Россия
Сент-Винсент и Гренадины
Южная Корея
Румыния
Сент-Китс и Невис
Япония
Сан-Марино
Сент-Люсия
Северная Македония
Синт-Мартен
Сербия
Соединенные Штаты Америки
Словакия
Тринидад и Тобаго
Словения
Ямайка
Украина
Фарерские о-ва
Финляндия
Франция
Хорватия
Черногория
Чехия
Швейцария
Швеция
Шпицберген
Эстония