Publique seus produtos
TWG Ventilace facade - complete solution
TWG Ventilace facade - complete solution
TWG Ventilace facade - complete solution

    TWG Ventilace facade - complete solution

    Traduzido pelo Google,

    Fachadas cobertas TWG são fachadas com sala de ventilação traseira entre isolamento térmico e

    Xterior Compact / Xterior Compact F ou para estruturas não isoladas e edifícios de madeira entre os suportes de carga

    Subterrâneo e Xterior Compact / Xterior Compact F. A sala de ventilação traseira deve-se às aberturas de entrada de ar no

    Aberturas inferiores e de exaustão de ar na parte superior da parede ou secções de parede (por exemplo

    tung) conectado ao ar externo e, assim, permite a troca constante de ar.

    Adquiridos atrás de fachadas ventiladas (VHF) consistem em:

    1. Xterior Compacto / Xterior Compacto F

    Eles servem para proteção contra intempéries e design de fachadas.

    2. Sugestão de ventilação

    A sala de ventilação traseira é uma área que flui do exterior entre o

    Dentro da roupa e fora da parede ou isolamento térmico. Isso serve a umidade

    Proteção das camadas por trás dele, a derivação de cargas de umidade de dentro ou de fora, bem como o

    Gestão do aquecimento do verão.

    3. Subestrutura

    As subestruturas para VHF podem ser feitas de metal, madeira ou plástico reforçado com fibra e combinações

    pode ser feito com esses materiais.

    4. Perfil de trote

    Os perfis Trot são elementos que combinam mecanicamente os componentes da subestrutura entre si.

    5. Ponto de fixação

    Os pontos de fixação são pontos que o Xterior Compact / Xterior Compact F na subestrutura mecha

    Fixe o nicho com elementos metálicos ou por meio de colagem.

    6. Material de isolamento

    Camada termicamente isolante entre a ancoragem e a sala de ventilação traseira; O isolamento térmico

    pode - dependendo do material - também cumprir funções de isolamento acústico e contra incêndio.

    7. Parede subterrânea

    A razão para a ancoragem é a construção resistente do edifício. Serve para registrar a estática

    cargas. A subestrutura está ancorada na estrutura.

    Camadas superficiais, por exemplo, gesso e revestimentos, geralmente não são sustentáveis.

    Especificação
    • Requirements for the Facadenko Ntrau

      Purchased behind ventilated facades (VHF) are mechanically connected to the structure and must at any time

      be stable. The following loads must be taken into account object -specific:

      - Own load

      - Wind loads (so -called and pressure)

      - and ice loads

      - shock loads

      - special loads (e.g. seismic loads, advertising boards)

      The proof of stability for the VHF system is, including all individually, in a testable form

      according to the state of the art and the respective European and/or national regulations accordingly

      provide. The proof of stability has in particular the static calculation of the substructure, which

      To contain clothing as well as the anchoring and connection elements.

      The own load results from the own weight of the clothing and substructure. Corresponding values

      can be removed from the technical data sheet.

      The wind loads have to be distinguished. The variables to be used in the calculation are

      Among other things, dependent on building geometry, the execution of the facade clothing and the building site.

      In traffic areas, special loads (impact, ball throw or similar) may have to be taken into account (closer distress

      de substructure etc.).

    Especificação técnica
    • Ref. únicaventilace-facade-complete-solution
    • Família de produtofacade
    • Grupo de produtoscomplete solution
    • TipoObjeto (objeto único)
    • Data de publicação2024-02-02
    • Número da edição1
    • Altura (mm)2070
    • Largura (mm)2800
    • Profundidade (mm)8
    Afins
    • Material principalPapel Laminado
    • Material secundárioMadeira
    • Desenhado emGermany
    • Fabricado emGermany
    • Peso Neto (kg)85
    Classificação
    • Categoria BIMobjectParedes - Revestimento
    • Classificação IFCParede Cortina
    • Código ETIMEG020350
    • Nome ETIMBuilding - Facade cladding
    • Nome UNSPSCSiding and exterior wall materials
    • Código UNSPSC301518
    • Código Uniclass 2015Ss_25_20
    • Descrição Uniclass 2015Wall cladding systems
    • CSI MasterFormat 2014 Code07 42 23
    • Título CSI MasterFormat 2014Wood Wall Panels
    • Número OmniClass23-13 33 19 11
    • Título OmniClassCladding and Curtainwall Panels
    • CSI UniFormat II CodeB2010
    • Título UniFormat II da CSIExterior Walls

    Disponibilidade regional

    Europa
    Austria
    Germany
    Switzerland