Publiceer je producten
Bioretention Planters, GFRC
Bioretention Planters, GFRC
Bioretention Planters, GFRC

    Bioretention Planters, GFRC

    GFRC - LIGHTWEIGHT CONCRETE

    Our bioretention planters are pre-built and installed on-site to collect stormwater from drain leads/downspouts. Plants and media filter water, removing organic and inorganic solids, and slowly release the water into the storm drains, reducing peak discharge rates.
    We offer a range of standard sizes in both aluminum and GFRC - Glass-fiber reinforced concrete, but most bioretention projects are custom.

    Specificatie
    • Guide Specification

      Section 129300 Site Furnishings
      Section 129200 Interior Planters

      Tournesol Siteworks Fiberglass Planters and Planter Liners

      1.0 GENERAL

      1.1 WORK INCLUDED

      A. Provision of fiberglass planters and planter liners

      1.2 RELATED WORK

      A. Section 033000 Cast-in-Place concrete

      B. Section 061000 Rough Carpentry

      C. Section 062000 Finish Carpentry

      1.3 SUBMITTALS

      A. Product Data: Manufacturer's standard catalog cut sheets.

      B. Samples: As required for color selection or material thickness only.

      C. Shop Drawings: For custom applications, showing critical sizes and dimensions for

      installation and integration with other work.

      1.4 DELIVERY, STORAGE AND HANDLING

      A. Unwrap and inspect planters and planter liners after delivery for signs of damage during

      transit.

      B. Protect planters and planter liners from damage during storage and handling.

      C. Store planters and planter liners indoors if possible. Do not stand or walk on planters or

      planter liners.

      1.5 PROJECT CONDITIONS

      A. Contractor to provide adequate structural support for planter liner units. Unless

      otherwise specified, planters and liners should have continuous basal support.

      B. Protect units from damage by adjacent work.

      2.0 PRODUCTS

      2.1 ACCEPTABLE PRODUCTS/MANUFACTURERS

      A. Fiberglass Planters and planter liners, manufactured by Tournesol Siteworks LLC. 30955

      San Antonio St., Hayward, CA 94544 Tel: (800) 542-2282 FAX (510) 471-6243

      2.2 FIBERGLASS PLANTERS AND PLANTER LINERS

      A. Materials - All parts shall be constructed of glass fiber-reinforced polyester resin, using

      either the hand-layup or spray-layup methods.

      1. Glass fibers shall be PPG or equivalent. For hand layup fibers should be uniform

      chopped strand mat, minimum 3 oz. density. Smaller round containers will use one layer

      of mat (or spray equivalent), smaller squares and larger round containers must use two

      layers (or spray equivalent), larger square and rectangular containers must use min. 3

      layers (or spray equivalent).

      2. Polyester resin shall be compounded by a reputable manufacturer. All planters and

      planter liners will be fabricated of 100% resin – inorganic fillers will not be acceptable.

      3. Gel coating (where necessary) shall be of specified color. Metallic finishes will use

      atomized metal thoroughly blended with polyester resin, and applied over clean surfaces.

      4. Painted finishes will be made of polyurethane low VOC (less than 2.8 VOC) enamel

      with excellent corrosion and chemical resistance by PPG (AUE 280) or equivalent.

      B. Construction

      Architectural parts shall be fabricated by hand-layup, spray laminate, or resin transfer

      method using suitable molds to attain the desired surface finish. The finished reinforced

      plastic material shall be not less than 5/32" thick and thicker in those areas requiring

      additional structural strength.

      Where ribs or stiffeners are to be fastened to liner sections by spray laminating over

      premolded forms, the stiffeners or ribs shall be located and spray laminated into position so

      that the finished joint shall conform to performance specifications below.

      For vertical surface reinforcement, an inorganic honeycomb strengthening layer using

      double-veiled, bonded material shall be located and hand- or spray-laminted into position

      prior to the wall material setting. The entire honeycomb panel must be subject to pressure

      during curing to ensure proper bonding to wall. Honeycomb thickness will be minimum

      ¼”, or thicker as required for larger spans. Marine-grade plywood may be substituted for

      bottom panels to be penetrated with drainage or irrigation holes.

      Interior of planter or planter liner to be waterproofed with additional layer of black gel

      coating, additional waterproofing available as specified.

      C. Performance characteristics and capacities, finished product to yield the following

      minimum performances:

      Hardness, Barcol 50

      Tensile Strength, Ultimate 12500 psi

      Elongation at break 1.3%

      Modulus of Elasticity 1020 ksi

      Flexural Modulus 754 ksi

      Flexural Yield Strength 27600 psi

      Compressive Yield Strength 21800 psi

      Glass content, average 35%

      Vertical wall panels will not deform more than L/200 when loaded with 80 lbs/cu ft. soil

      mass. Similar performance with heavier media is available per specification.

      D. Finish: specified finish; factory finished.

      E. Sizes: Modular units fabricated to size by manufacturer as required to fill specified

      areas. Refer to catalog for standard sizes. Custom sizes as per approved shop drawings.

      F. Fire retardant requirement can be met with the addition of retardant chemicals to the

      resin. Additional information is available for this specification.

      2.3 PLANTER ACCESSORIES

      A. Field installed drainage/irrigation connection fitting. Thread-by-thread thermoplastic

      drainage adapter, ½”, ¾” and 1"NPT female thread available. Contractor to locate drainage

      hole, drill as necessary, and install fitting.

      B. Lifting hooks or stabilizer anchors, quantity, size, and capacity as specified.

      3.0 EXECUTION

      3.1 PREPARATION

      A. Prior to planter or planter liner fabrication, the contractor shall verify as-built dimensions

      of planter area or receptacles to ensure proper size, fit and quantity required.1

      B. Unless planters have drainage fittings as in 2.3.A, drainage holes to be located and made

      by contractor in the field to fit to drainage system.

      3.2 INSTALLATION

      A. Install planter liners to allow for easy removal if necessary.

      B. Provide continuous basal support.

      C. Install liners level to permit adequate drainage and irrigation.

      1 Field verification of actual planter receptacle size is frequently overlooked by the contractor, and can

      lead to delays and additional cost if neglected.

    Technische specificatie
    • Unieke ref.bioretention-planters-gfrc
    • ProductfamilieBioretention Planters
    • ProductgroepBioretention GFRC
    • TypeObject (enkelvoudig object)
    • Publicatiedatum2024-06-04
    • Editienummer1
    Gerelateerd
    • HoofdmateriaalBeton
    • Ontworpen inVerenigde Staten
    • Gefabriceerd inVerenigde Staten
    Classificatie
    • Categorie BIMobjectTuinaanleg - Landschap

    Beschikbaarheid regio

    Europa Noord Amerika Azië Zuid-Amerika
    Åland
    Amerikaanse Maagdeneilanden
    Armenië
    Argentinië
    Albanië
    Anguilla
    Azerbeidzjan
    Bolivia
    Andorra
    Antigua en Barbuda
    Bangladesh
    Brazilië
    België
    Aruba
    Bhutan
    Chili
    Bosnië en Herzegovina
    Bahama's
    Brits Indische Oceaanterritorium
    Colombia
    Bulgarije
    Barbados
    Brunei
    Ecuador
    Cyprus
    Belize
    Cambodja
    Falklandeilanden (Islas Malvinas)
    Denemarken
    Bermuda
    China
    Frans-Guyana
    Duitsland
    Britse Maagdeneilanden
    Christmaseiland
    Guyana
    Estland
    Canada
    Cocoseilanden
    Paraguay
    Faeröer
    Caribisch Nederland
    Filipijnen
    Peru
    Finland
    Costa Rica
    Georgië
    Suriname
    Frankrijk
    Cuba
    Hongkong
    Uruguay
    Gibraltar
    Curaçao
    India
    Venezuela
    Griekenland
    Dominica
    Indonesië
    Guernsey
    Dominicaanse Republiek
    Japan
    Hongarije
    El Salvador
    Kazachstan
    Ierland
    Grenada
    Kirgistan
    IJsland
    Groenland
    Laos
    Isle of Man
    Guadeloupe
    Macau
    Italië
    Guatemala
    Maldiven
    Jersey
    Haïti
    Maleisië
    Kroatië
    Honduras
    Mongolië
    Letland
    Jamaica
    Myanmar (Birma)
    Liechtenstein
    Kaaimaneilanden
    Nepal
    Litouwen
    Martinique
    Noord-Korea
    Luxemburg
    Mexico
    Oezbekistan
    Malta
    Montserrat
    Pakistan
    Moldavië
    Nicaragua
    Singapore
    Monaco
    Panama
    Sri Lanka
    Montenegro
    Porto Rico
    Tadzjikistan
    Nederland
    Saint Kitts en Nevis
    Taiwan
    Noord-Macedonië
    Saint Martin
    Thailand
    Noorwegen
    Saint Vincent en de Grenadines
    Turkmenistan
    Oekraïene
    Saint-Barthélemy
    Vietnam
    Oostenrijk
    Saint-Pierre en Miquelon
    Zuid-Korea
    Polen
    SaintLucia
    Portugal
    Sint Maarten
    Roemenië
    Trinidad en Tobago
    Rusland
    Turks- en Caicoseilanden
    San Marino
    Verenigde Staten
    Servië
    Slovenië
    Slowakije
    Spanje
    Spitsbergen
    Tsjechië
    Vaticaanstad
    Verenigd Koninkrijk
    Wit-Rusland
    Zweden
    Zwitserland