제품 게시
Negative Pressure Infrared Heater - Series TVX

Negative Pressure Infrared Heater - Series TVX

The Series TVX negative pressure multi-burner system was designed to use two or more radiant tube heaters in a variety of applications, these systems offer significant operating benefits that are not easily obtainable with traditional infrared tube heaters.

Flexible layouts (Herringbone, Fork, "T", Flag, etc.) can be adapted to fit a wide range of applications heating and space requirements. Available input rates 60 / 80 / 100 / 125 / 150 / 175 / 205 / 220 MBH all featuring a two-stage configuration.

Features

  •   Input rates 60 to 220 MBH
  •   Lengths –  from 20’ to 60’
  •   Two-stage for comfort control 
  •   100% efficient reflector 
  •   Sealed burner box 
  •   3 try ignition 
  •   Integral safety switch  
  •   Simple controls 
  •   Multi-zone capability
  •   State-of-the-art pump with ECM motor
  •   Up to 525 MBH on single vent penetration
  •   Easy setup and commissioning 
  •   Standard gas flex and shut off valve are used
  •   Installation benefits – fewer vents needed
  •   Optional Equipment:
    • Elbows, Utube, outside air kit
    • Side shields, deco grille, bottom shield
사양
  • Low Intensity, Two-Stage, Negative pressure Infrared Tube Heating System - Heavy duty industrial/commercial infrared heating system, featuring the best overall radiant performance in the industry. Firing rates as called for in the Contract documents within the range of 60/45 MBH to 220/165 MBH. 100% efficient reflector design with minimum 65% radiant factor as determined by independent lab testing to EN416 Standard. Baffles required as per manufacturer’s instructions. Product shall be Custom-designed, Negative Pressure, Low-Intensity Infrared Heating System: Model TVX as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks to be conducted with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish design with emitter tubes fully recessed within reflector. Reflectors shall have a minimum of 10 reflective surfaces. Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024-inch thickness aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall always extend below the lowest position of the tubing and include standard end caps. Reflector end caps: Shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4-inch (102 mm) diameter, minimum 16-gauge thickness, hot rolled steel, heat-treated type 1 aluminized steel or type 409 stainless steel materials. Heat Uniformity: Burner shall distribute hot gases along the length of the emitter tubes. Combustion Tube shall be 4 inches (102 mm) diameter, 16-gauge, heat-treated type 1 aluminized steel tubing for all firing rates. Hot rolled steel shall not be allowed. The combustion tube shall incorporate a continuously welded, 11-gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16-gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands. Exhaust pump motor shall be totally enclosed requiring no oiling and shall be equipped with overcurrent protection. It shall be one of A. For systems up to 250,000 BTU/Hr - Permanent Split Capacitor (PSC) type, Electrical supply: 120V, 60Hz, 1 PH, 1 A.B. For systems up to 525,000 BTU/Hr - Electrically Commutated Motor (ECM) Electrical supply 120V, 60Hz, 1 PH, 5 A. This product was specified based on best practice design to meet the specific engineering design criteria for this project. No Substitution Permitted. Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:- Independent lab testing to EN416 standard dated no later than 6 months from date of submission showing minimum 65% radiant factor.- Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.- Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model - Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).

기술 사양
  • 특징 참조tvx
  • 제품군Negative Pressure Systems
  • 제품분류Series TVX
  • 유형개체 (단일 개체)
  • 게시일2021-02-16
  • 에디션 넘버1
관련성
  • 주 재료
  • 부 재료알루미늄
  • 설계국가캐나다
  • 제조국가캐나다
분류
  • BIMobject 카테고리HVAC - 히터
  • IFC 분류스페이스히터
  • UNSPSC 이름Space heaters
  • UNSPSC 코드40101819
  • Uniclass 2015 코드Pr_70_60_36_72
  • Uniclass 2015 설명Radiant tube heaters
  • CSI 마스터 형식 2014 코드23 55 23
  • CSI 마스터 형식 2014 제목Gas-Fired Radiant Heaters
  • OmniClass 번호23-33 15 17 13
  • OmniClass 제목Fuel Fired HVAC Radiant Heaters
  • CSI 단일 형식 II 코드D30
  • CSI 단일 형식 II 제목HVAC

지역 가용성

유럽 북미 아시아
건지
과들루프
네팔
그리스
과테말라
대만
네덜란드
그레나다
대한민국
노르웨이
그린란드
라오스
덴마크
네덜란드령 카리브 해 지역
마카오
독일
니카라과
말레이시아
라트비아
도미니카
몰디브
러시아
도미니카 공화국
몽고
루마니아
마르티니크
미얀마(버마)
뤽상부르
멕시코
방글라데시
리투아니아
몬세라트
베트남
리히텐슈타인
미국
부탄
맨섬
미국령 버진아일랜드
브루나이
모나코
바베이도스
스리랑카
몬테네그로
바하마
싱가포르
몰도바
버뮤다
아르메니아
몰타
벨리즈
아제르바이잔
바티칸 시국
생마르탱
영국령 인도양 지역
벨기에
생바르텔레미
우즈베키스탄
벨로루시
생피에르앤드미클롱
인도
보스니아 헤르체고비나
세인트루시아
인도네시아
북마케도니아
세인트빈센트그레나딘
일본
불가리아
세인트키츠네비스
조선민주주의인민공화국
산마리노
신트마르턴
조지아
세르비아
아루바
중국
스발바르 얀마옌 제도
아이티
카자흐스탄
스웨덴
앤티가 바부다
캄보디아
스위스
앵귈라
코코스 제도
스페인
엘살바도르
크리스마스섬
슬로바키아
영국령 버진아일랜드
키르기스스탄
슬로베니아
온두라스
타지키스탄
아이슬란드
자메이카
태국
아일랜드
캐나다
투르크메니스탄
안도라
케이맨 군도
파키스탄
알바니아
코스타리카
필리핀
에스토니아
쿠바
홍콩
영국
퀴라소
오스트리아
터크스케이커스 제도
올란드 제도
트리니다드토바고
우크라이나
파나마
이탈리아
푸에르토리코
저지섬
지브롤터
체코 공화국
크로아티아
키프러스
페로 제도
포르투갈
폴란드
프랑스
핀란드
헝가리