제품 게시
Two Stage Infrared Heater, Model TA

Two Stage Infrared Heater, Model TA

Heavy duty industrial/commercial infrared heater featuring the best overall performance in the industry. All Series T units include Hi-Low output capability which allows quicker recovery on the high fire and economical steady operation on the low fire. 40 MBH to 220 MBH rates available with 100% efficient reflector. Natural Gas or LPG.

  • Two-stage heater – dual output for improved rate differential, 40,000 to 220,000 BTU/h
  • Natural Gas or LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated controls compartment – electronics out of air stream, the burner can run during servicing
  • Self-diagnostic ignition module
  • Parabolic aluminum reflectors – most efficient in the industry
  • Direct spark ignition
  • Vented or unvented
  • Hinged service cover – easy to service
  • Jet Stream burner – improved heat distribution, better combustion
  • Heavy-duty couplings – no leaks, cannot be over tightened
  • Operating status lights
  • Low voltage controls
  • Three-year warranty on all components
  • Five-year warranty on hot rolled heat exchanger
  • Seven-year warranty on aluminized heat exchanger with post purge feature
  • 10-year warranty on optional aluminized heat exchanger with post purge feature
  • Post purge


사양
  • Low-Intensity Two Stage Infrared Tube Heaters. Heavy-duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents within the range of 40/30 MBH to 220/165 MBH with a minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. The product shall be (please select model for unique specification) Model TA (sealed blower design), Model TX (enclosed burner design), or Model TXR (enclosed, moisture sealed burner design for rugged, harsh environments or outdoor use) as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks shall be possible with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors shall have a minimum of 10 reflective surfaces.  Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing, and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution most include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model. 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
기술 사양
  • 특징 참조ta
  • 제품군Two Stage Infrared Heaters
  • 제품분류Low Intensity - Series T
  • 유형개체 (단일 개체)
  • 게시일2021-02-16
  • 에디션 넘버1
관련성
  • 주 재료
  • 부 재료알루미늄
  • 설계국가캐나다
  • 제조국가캐나다
분류
  • BIMobject 카테고리HVAC - 히터
  • UNSPSC 이름Tubular heaters
  • UNSPSC 코드40101822
  • Uniclass 2015 코드Pr_70_60_36_72
  • Uniclass 2015 설명Radiant tube heaters
  • CSI 마스터 형식 2014 코드23 55 23
  • CSI 마스터 형식 2014 제목Gas-Fired Radiant Heaters
  • OmniClass 번호23-33 15 17 13
  • OmniClass 제목Fuel Fired HVAC Radiant Heaters
  • CSI 단일 형식 II 코드D30
  • CSI 단일 형식 II 제목HVAC

지역 가용성

유럽 북미 아시아
건지
과들루프
네팔
그리스
과테말라
대만
네덜란드
그레나다
대한민국
노르웨이
그린란드
라오스
덴마크
네덜란드령 카리브 해 지역
마카오
독일
니카라과
말레이시아
라트비아
도미니카
몰디브
러시아
도미니카 공화국
몽고
루마니아
마르티니크
미얀마(버마)
뤽상부르
멕시코
방글라데시
리투아니아
몬세라트
베트남
리히텐슈타인
미국
부탄
맨섬
미국령 버진아일랜드
브루나이
모나코
바베이도스
스리랑카
몬테네그로
바하마
싱가포르
몰도바
버뮤다
아르메니아
몰타
벨리즈
아제르바이잔
바티칸 시국
생마르탱
영국령 인도양 지역
벨기에
생바르텔레미
우즈베키스탄
벨로루시
생피에르앤드미클롱
인도
보스니아 헤르체고비나
세인트루시아
인도네시아
북마케도니아
세인트빈센트그레나딘
일본
불가리아
세인트키츠네비스
조선민주주의인민공화국
산마리노
신트마르턴
조지아
세르비아
아루바
중국
스발바르 얀마옌 제도
아이티
카자흐스탄
스웨덴
앤티가 바부다
캄보디아
스위스
앵귈라
코코스 제도
스페인
엘살바도르
크리스마스섬
슬로바키아
영국령 버진아일랜드
키르기스스탄
슬로베니아
온두라스
타지키스탄
아이슬란드
자메이카
태국
아일랜드
캐나다
투르크메니스탄
안도라
케이맨 군도
파키스탄
알바니아
코스타리카
필리핀
에스토니아
쿠바
홍콩
영국
퀴라소
오스트리아
터크스케이커스 제도
올란드 제도
트리니다드토바고
우크라이나
파나마
이탈리아
푸에르토리코
저지섬
지브롤터
체코 공화국
크로아티아
키프러스
페로 제도
포르투갈
폴란드
프랑스
핀란드
헝가리