Features
  • Herr-Voss corrective leveled
  • Pencil ribs (stiffening beads) and striations are only available by request
  • 30-year non-prorated finish warranty
  • Maximum factory-produced panel length is 64’ (check w/factory for longer lengths)
  • Weathertightness warranty available

Tite-Loc panels combine structural panel performance with architectural panel aesthetics. Tite-Loc panels are corrective leveled to provide superior panel flatness. A factory-applied sealant bead is applied for additional weather resistance. Maximum panel length is 64’ and minimum panel length is 4’. Consult factory for longer lengths.
Tite-Loc panels feature a 2” leg height that requires mechanical field seaming after installation. Panels have a concealed-fastener floating clip system designed to allow for thermal expansion/contraction.

Trim

All flashing and trim shall be fabricated by manufacturer or qualified fabricator. Flashing shall be PAC-CLAD aluminum (.032 – .063 gauge as specified) or PAC-CLAD steel (24 gauge or 22 gauge as specified). A 30-year non-prorated finish warranty can be supplied covering finish performance. Vinyl masking is recommended on all fabrication applications where extra handling is expected. NOTE: The strippable film must be removed immediately after installation.

Installation

Tite-Loc panels are intended for use in architectural and structural roofing. Substrates may include 5/8” (min.) plywood, nailboard insulation or equal with an underlayment of ice and water shield or 30# (min.) roofing felt applied horizontally from eave to ridge. Other substrates may include metal decking, purlins or rigid insulation in conjunction with bearing plates. A minimum 1/2:12 pitch is required. Contact Petersen Aluminum for further assistance with projects details.

For coastal applications, aluminum panels along with stainless steel clips must be used for finish warranty. Consult a local architect/engineer for compliance with local codes and conditions.

Tite-Loc Panels

Tite-Loc panels are factory-formed to length and field-seamed to a 90˚ lock. The panels have been designed for application over a wide variety of substrates on roof slopes as low as 1/2:12 pitch. Available in 12”, 16” and 18” widths, Tite-Loc panels can be produced in 22 and 24 gauge steel or .032 and .040 aluminum.

Tite-Loc Seaming

The Tite-Loc seamer is bi-directional, offering labor savings with the ability to travel up and down slope. However, the seamer should only be used up slope on roofs with a pitch of 6:12 or less.

Curved Tite-Loc Roofing Panels

The Tite-Loc panels can be curved to a minimum radius of 20’. Tite-Loc curving can be done in the field or at the factory depending on the radius and length of the panel.

For more details about our curving capabilities, please contact your local Petersen Aluminum factory.

기술 사양
  • 특징 참조roof-panel-pac-clad-tite-loc
  • 제품군Roof Panels
  • 제품분류Roof Panels
  • 유형개체 (단일 개체)
  • 게시일2015-06-09
  • 에디션 넘버1
관련성
  • 설계국가미국
  • 제조국가미국
분류
  • BIMobject 카테고리건축 - 지붕
  • IFC 분류지붕
  • UNSPSC 이름Roofing materials
  • UNSPSC 코드301515
  • Uniclass 2015 코드Pr_25_93_72
  • Uniclass 2015 설명Roofing and cladding units
  • CSI 마스터 형식 2014 코드07 40 00
  • CSI 마스터 형식 2014 제목Roofing and Siding Panels
  • OmniClass 번호23-13 39 27
  • OmniClass 제목Roof Cladding

지역 가용성

북미
미국