제품 게시
Commercial Indoor/Outdoor Tankless Water Heater
Commercial Indoor/Outdoor Tankless Water Heater
    A. O. Smith

    Commercial Indoor/Outdoor Tankless Water Heater

    4.3 out of 5 stars4.3(15 reviews)

    Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to
    0.95 Uniform Energy Factor (UEF) which lowers operating costs and is environmentally
    friendly.



    사양
    • TANKLESS CONDENSING HIGH EFFICIENCY SPECIFICATIONS

      The fully modulating, on-demand, condensing gas fired tankless water heater(s) shall be A.O. Smith model CT-199, having a maximum input
      rating of 199,000 Btu/h and available in NG or LP. The heater shall have ¾ in. male NPT water and gas connections. The inlet gas supply
      pressures shall be 4.0 in. WC (min.) up to 10.5 in. WC (max) for NG and 8.0 in. WC (min.) up to 14 in. WC (max.) for LP. The indoor heater(s)
      shall incorporate an integrated temperature controller that will provide diagnostic information, fault history, and heater set temperature. The
      outdoor heater(s) shall be factory supplied with a temperature remote, 100112572, that can be installed up to 400 ft. from the heater using
      18 gauge (minimum) control wire. The temperature remote shall provide diagnostic information, fault history, and heater set temperature. The
      heater(s) shall operate using 120 V / 60 Hz power source. The indoor heater(s) will incorporate a factory installed power cord.
      The indoor heater(s) shall be vented with 3” or 4” diameter schedule 40 PVC, CPVC, ABS, or Category IV vent pipe with a length not to exceed
      70 ft. (equivalent) for 3” vent or 100 ft. (equivalent) for 4” vent, terminating horizontally or vertically. The intake pipe may use material such
      as PVC, ABS, aluminum, or Category IV pipe and cannot exceed 70 ft. (equivalent) for 3” vent or 100 ft. (equivalent) for 4” vent. The outdoor
      heater(s) shall be constructed with an integral exhaust vent on the front of the heater.
      The water heater(s) shall use a commercial-grade copper, fin tube primary heat exchanger with quick release brass or bronze waterways. The
      secondary heat exchanger shall be constructed from stainless steel 316L. The heater(s) shall be controlled by an on-board solid-state printed
      circuit board which uses the following factory installed components: thermistors to monitor water temperature and exhaust temperature; a flow
      sensor to measure flow rate; a flame sensor to monitor combustion; an Air-Fuel Ratio Rod to measure and adjust air input in order to maintain
      optimal combustion efficiency. The heater also consists of in-line fusing and surge absorbers for electrical surge protection, an electronic spark
      igniter, aluminized stainless steel burners, hi-limit temperature switches to monitor water and exhaust temperatures, modulating gas valve,
      dual freeze protection that will automatically fire the heater (indoor model only) and use heating blocks to protect the heat exchanger, and an
      overheat cutoff fuse.
      The heater(s) can manifold to Easy-Link up to 4 heaters to provide additional capacity. The Easy-Link controls shall be built onto the on-board
      solid state printed circuit board and does not require external controls. The linking control wire shall be supplied with the heater. The heater(s)
      can use a Multi-Unit controller, 100112691, to manifold 5-20 heaters. The Easy-Link and Multi-Unit Controller shall modulate the system for the
      most efficient performance. The Easy-Link and Multi-Unit Controller shall rotate the priority heater every 12 hours of operation time or 100 starts
      for balanced duty/cycle operation.
      The heater models are design certified by CSA according to ANSI Z21.10.3 · CSA 4.3, approved for sale in the United States, ENERGY STAR®
      qualified, has a minimum uniform energy factor of 0.93, meets the energy efficiency requirements of the U. S. Department of Energy and ASHRAE
      90.1, complies with SCAQMD Rule 1146.2 and other air quality districts with similar requirements for low NOx emissions of 14 ng/J or 20 ppm,
      and shall be certified to NSF 5 standards.

    기술 사양
    • 특징 참조aosmith_CT-199
    • 제품군Commercial Tankless Water Heater
    • 제품분류Tankless
    • 유형개체 (단일 개체)
    • 게시일2019-10-18
    • 에디션 넘버1
    관련성
    • 주 재료구리
    • 부 재료스테인레스강
    • 설계국가일본
    • 제조국가일본
    분류
    • BIMobject 카테고리HVAC - Water heaters
    • ETIM 코드EC000392
    • ETIM 이름Instantaneous water heater
    • Uniclass 2015 코드Pr_60_60_96_33
    • Uniclass 2015 설명Gas-fired instantaneous water heaters
    • CSI 마스터 형식 2014 코드22 34 13
    • CSI 마스터 형식 2014 제목Instantaneous, Tankless, Gas Domestic Water Heaters
    • OmniClass 번호23-31 29 11 13
    • OmniClass 제목Gas Instantaneous Hot Water Heaters
    • CSI 단일 형식 II 코드D3090
    • CSI 단일 형식 II 제목Other HVAC Systems & Equipment

    지역 가용성

    북미
    과들루프
    과테말라
    그레나다
    그린란드
    네덜란드령 카리브 해 지역
    니카라과
    도미니카
    도미니카 공화국
    마르티니크
    멕시코
    몬세라트
    미국
    미국령 버진아일랜드
    바베이도스
    바하마
    버뮤다
    벨리즈
    생마르탱
    생바르텔레미
    생피에르앤드미클롱
    세인트루시아
    세인트빈센트그레나딘
    세인트키츠네비스
    신트마르턴
    아루바
    아이티
    앤티가 바부다
    앵귈라
    엘살바도르
    영국령 버진아일랜드
    온두라스
    자메이카
    캐나다
    케이맨 군도
    코스타리카
    쿠바
    퀴라소
    터크스케이커스 제도
    트리니다드토바고
    파나마
    푸에르토리코