Viewrail maintains certain standards and requirements that must be met. If these requirements are not reached, Viewrail will not be able to produce a Stack system for the client. Please verify your project meets our standard rules:
- Max Tread Width - 60”
- Min Tread Width - 27” between glass; 34” between opening
- Max Tread Depth - 13”
- Min Tread Depth - 11”, no nosing
- Code Compliance - Follows IRC, IBC, & ICC Standards on the rise
- Railing - Always Vedera Glass, no other option
- 1/2” tempered
- 9/16” laminate
- Pans - No pans for 12 treads and under.
- Systems between 12-15 treads can be freestanding, but need pans for extra support.
- Systems at or over 15 treads - Requires additional engineering; must go through R&D
- Requires pans and most likely wall blocking on one side
- Systems at or over 12 treads - If you are without wall blocking on either side, you will require a custom solution
- Requires feasibility check, cannot be waived.