Condair Esco 10 DL40 - with 3x steam pipe
This is a configured product. Please contact your Condair partner for a selection according to your air handling unit or duct dimensions and the required humidity.
Take care about the humidification distance downstream of the steam pipe. This distance is variable and depends on the given air conditions on site. Therefore, it's not possible to show this kind of clearance in the files directly. The humidification distance must be handled like a clearance. No obstacles can be placed within this distance.
Accessories shown in the models:
- Electric Actuator Condair CA150A-MP
- Steam Trap Spirax Sarco: Type Ball Float and Thermostatic
- Pressure Gauge
Esco 10 - DL40 Triple Pipe Type Overview
- Admissible steam over pressure: 0.2 ... 4.0 bar
- Min. required air handling unit / duct height: 1000 mm
Collector Dimensions:
- 250 mm, 300 mm, 600 mm or 900 mm distance between the steam pipes available
Collector max. admissible steam capacity [kg/h]
The collector type max. steam capacity must be higher, than the present steam capacity.
Type 3-10/023:
- Max. Steam Capacity 48 kg/h
- Air Handling Unit (AHU) / Duct width: 250 ... 399 mm
- Required Collector Capacity 116 kg/h
Type 3-10/038:
- Max. Steam Capacity 81 kg/h
- Air Handling Unit (AHU) / Duct width: 400 ... 499 mm
- Required Collector Capacity 116 kg/h
Type 3-10/048:
- Max. Steam Capacity 96 kg/h
- Air Handling Unit (AHU) / Duct width: 500 ... 599 mm
- Required Collector Capacity 116 kg/h
Type 3-10/058:
- Max. Steam Capacity 123 kg/h
- Air Handling Unit (AHU) / Duct width: 600 ... 699 mm
- Required Collector Capacity 116 or 211 kg/h, depends on the present steam capacity
Type 3-10/068:
- Max. Steam Capacity 150 kg/h
- Air Handling Unit (AHU) / Duct width: 700 ... 899 mm
- Required Collector Capacity 116 or 211 kg/h, depends on the present steam capacity
Type 3-10/088:
- Max. Steam Capacity 186 kg/h
- Air Handling Unit (AHU) / Duct width: 900 ... 1199 mm
- Required Collector Capacity 116 or 211 kg/h, depends on the present steam capacity
Type 3-10/118:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU) / Duct width: 1200 ... 1499 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity
Type 3-10/148:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU) / Duct width: 1500 ... 1799 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity
Type 3-10/178:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU) / Duct width: 1800 ... 2099 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity
Type 3-10/208:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU) / Duct width: 2100 ... 2399 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity
Type 3-10/238:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU)/ Duct width: 2400 ... 2699 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity
Type 3-10/268:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU) / Duct width: 2700 ... 2998 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity
Type 3-10/298:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU) / Duct width: 3000 ... 3299 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity
Type 3-10/328:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU) / Duct width: 3300 ... 3599 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity
Type 3-10/358:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU) / Duct width: 3600 ... 3899 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity
Type 3-10/388:
- Max. Steam Capacity 250 kg/h
- Air Handling Unit (AHU) / Duct width: 3900 ... 4299 mm
- Required Collector Capacity 116, 211 or 250 kg/h, depends on the present steam capacity