Pubblica i tuoi prodotti
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert
    Watts

    Lead Free* Reduced Pressure Zone Assemblies, Bronze - LF909 Large - with SentryPlus Alert

    4.0 su 5 stelle4.0(13 recensioni)

    Series LF909-FS Large reduced pressure valve assembly backflow preventer is designed to prevent the reverse flow of liquids in a plumbing system due to backpressure or backsiphonage where there is a potential health hazard. An exclusive relief valve design provides substantially improved relief valve discharge performance during emergency conditions of combined backsiphonage and backpressure. These large diameter backflow preventers are available in 2-1/2 to 10 inch sizes.

    The coating on this backflow assembly uses ArmorTek™ technology to resist corrosion due to microbial induced corrosion (MIC) or exposed metal substrate.

    This series features an integrated flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. Activated through an add-on connection kit, the sensor can trigger the alert system sending notification of flood detection to facility personnel. Connection kits are available for BMS and cellular communication.

    Voce di capitolato
    • Features

      • Integrated sensor on relief valve for flood detection
      • Flood alert feature available with add-on connection kit, compatible with BMS and cellular communication
      • Coated with advanced ArmorTek coating technology for 6x less surface rusting
      • Health hazard protection level
      • Exclusive relief valve design provides maximum capacity during emergency conditions
      • Industrial strength sensing hose on larger size models
      • Can be used in a variety of installations, including containment at the service line entrance
      • No special tools required for servicing

      Keywords: anti-siphon, apex, armless trough valve, backflow, backflow valve, big al, bottom entry, breaker, bypass, c200, cast iron, castiron, check valve, checkvalve, dcda, detector, detector assembly, diaphragm, diaphragm activated, differential, domestic, double, double check, double check detector, doublecheck, dual level, epoxy, fire systems, full flow, hi flow, high flow, high flow rate, lead free, lf, lf,iot,flood detection,sentry+,sentry+ alert, livestock proof, meter, nrs, osy, polymer coating, pressure, pressure valve, preventer, qt, quarter turn shutoff, quarterturn, quaterturn, reduce pressure valve, reduce pressure zone, reducing valve, repair, repair kit, rpza, service, service kit, shut off, shut-off, side entry, ss check, ss dcda, ss double check, stainless steel, stainless steel body, strainer, tank valve, thermal expansion,, tri-link, vacuum, valve, vlv, water pressure

    Specifiche tecniche
    • Rif. UnicoReduced-pressure-zone-assembly-LF909-SentryPlus-Alert
    • Famiglia di prodottoPlumbing & Flow Control Solutions
    • Gruppo di famigliaBackflow Preventers > Reduced Pressure Detector Assemblies
    • TipoOggetto (oggetto singolo)
    • Data di pubblicazione2019-10-17
    • Numero di versione2
    Relativo a
    • Progettato inStati Uniti
    • Prodotto inStati Uniti
    Classificazioni
    • Categoria BIMobjectImpianto idraulico - Valvole
    • Clasificazione IFCValvola
    • Nome UNSPSCValves
    • Codice UNSPSC401416
    • Codice Uniclass 2015Pr_65_54_95_05
    • Descrizione Uniclass 2015Backflow prevention devices
    • Codice CSI MasterFormat 201440 05 67.13
    • Titolo CSI MasterFormat 2014Reduced-Pressure Zone Backflow Preventers for Process Service
    • Numero OmniClass23-27 31 11
    • Titolo OmniClassBackflow Preventors
    • Codice CSI UniFormat IIC1030
    • Titolo CSI UniFormat IIFittings

    Disponibilità Regionale

    Nord America
    Canada
    Stati Uniti