Two Stage Infrared Heater, Model TA

Two Stage Infrared Heater, Model TA

Heavy duty industrial/commercial infrared heater featuring the best overall performance in the industry. All Series T units include Hi-Low output capability which allows quicker recovery on the high fire and economical steady operation on the low fire. 40 MBH to 220 MBH rates available with 100% efficient reflector. Natural Gas or LPG.

  • Two-stage heater – dual output for improved rate differential, 40,000 to 220,000 BTU/h
  • Natural Gas or LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated controls compartment – electronics out of air stream, the burner can run during servicing
  • Self-diagnostic ignition module
  • Parabolic aluminum reflectors – most efficient in the industry
  • Direct spark ignition
  • Vented or unvented
  • Hinged service cover – easy to service
  • Jet Stream burner – improved heat distribution, better combustion
  • Heavy-duty couplings – no leaks, cannot be over tightened
  • Operating status lights
  • Low voltage controls
  • Three-year warranty on all components
  • Five-year warranty on hot rolled heat exchanger
  • Seven-year warranty on aluminized heat exchanger with post purge feature
  • 10-year warranty on optional aluminized heat exchanger with post purge feature
  • Post purge


Voce di capitolato
  • Low-Intensity Two Stage Infrared Tube Heaters. Heavy-duty industrial/commercial infrared heater featuring the best overall performance in the industry. Firing rates as called for in the Contract documents within the range of 40/30 MBH to 220/165 MBH with a minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. The product shall be (please select model for unique specification) Model TA (sealed blower design), Model TX (enclosed burner design), or Model TXR (enclosed, moisture sealed burner design for rugged, harsh environments or outdoor use) as manufactured by Superior Radiant Products. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz. Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks shall be possible with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors shall have a minimum of 10 reflective surfaces.  Reflectors with fewer surfaces allow energy to bounce back to the main heat exchanger tubing, and shall not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.  

    Any submission for substitution most include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with the new system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model. 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Specifiche tecniche
  • Rif. Unicota
  • Famiglia di prodottoTwo Stage Infrared Heaters
  • Gruppo di famigliaLow Intensity - Series T
  • TipoOggetto (oggetto singolo)
  • Data di pubblicazione2021-02-16
  • Numero di versione1
Relativo a
  • Materiale principaleAcciaio
  • Materiale secondarioAlluminio
  • Progettato inCanada
  • Prodotto inCanada
Classificazioni
  • Categoria BIMobjectRiscaldamento, ventilazione e condizionamento - Riscaldatori e radiatori
  • Nome UNSPSCTubular heaters
  • Codice UNSPSC40101822
  • Codice Uniclass 2015Pr_70_60_36_72
  • Descrizione Uniclass 2015Radiant tube heaters
  • Codice CSI MasterFormat 201423 55 23
  • Titolo CSI MasterFormat 2014Gas-Fired Radiant Heaters
  • Numero OmniClass23-33 15 17 13
  • Titolo OmniClassFuel Fired HVAC Radiant Heaters
  • Codice CSI UniFormat IID30
  • Titolo CSI UniFormat IIHVAC

Disponibilità Regionale

Europa Nord America Asia
Albania
Anguilla
Armenia
Andorra
Antigua e Barbuda
Azerbaijan
Austria
Aruba
Bangladesh
Belgio
Bahamas
Bhutan
Bielorussia
Barbados
Brunei
Bosnia ed Erzegovina
Belize
Cambogia
Bulgaria
Bermuda
Cina
Cipro
Canada
Corea del Nord
Città del Vaticano
Costa Rica
Corea del Sud
Croazia
Cuba
Filippine
Danimarca
Curaçao
Georgia
Estonia
Dominica
Giappone
Finlandia
El Salvador
Hong Kong
Francia
Giamaica
India
Germania
Grenada
Indonesia
Gibilterra
Groenlandia
Isola di Natale
Grecia
Guadalupa
Isole Cocos (Keeling)
Guernsey
Guatemala
Kazakistan
Irlanda
Haiti
Kirghizistan
Islanda
Honduras
Laos
Isola di Man
Isole BES
Macau
Isole Åland
Isole Cayman
Maldive
Isole Faroe
Isole Turks e Caicos
Malesia
Italia
Isole Vergini Americane
Mongolia
Jersey
Isole Vergini britanniche
Myanmar (Burma)
Lettonia
Martinica
Nepal
Liechtenstein
Messico
Pakistan
Lituania
Montserrat
Singapore
Lussemburgo
Nicaragua
Sri Lanka
Macedonia del Nord
Panamá
Tagikistan
Malta
Porto Rico
Tailandia
Moldavia
Repubblica Dominicana
Taiwan
Monaco
Saint Kitts e Nevis
Territori Britannici dell'Oceano Indiano
Montenegro
Saint Martin
Turkmenistan
Norvegia
Saint Vincent e Grenadine
Uzbekistan
Paesi Bassi
Saint-Barthélemy
Vietnam
Polonia
Saint-Pierre e Miquelon
Portogallo
Santa Lucia
Regno Unito
Sint Maarten
Repubblica Ceca
Stati Uniti
Romania
Trinidad e Tobago
Russia
San Marino
Serbia
Slovacchia
Slovenia
Spagna
Svalbard e Jan Mayen
Svezia
Svizzera
Ucraina
Ungheria