Pubblica i tuoi prodotti
OS2 SHEVTEC 1 Zone 16A Controller
OS2 SHEVTEC 1 Zone 16A Controller
OS2 SHEVTEC 1 Zone 16A Controller
OS2 SHEVTEC 1 Zone 16A Controller
OS2 SHEVTEC 1 Zone 16A Controller

OS2 SHEVTEC 1 Zone 16A Controller

The OS2 SHEVTEC 1 Zone 16A Controller is a powerful 24V dc control system designed to drive 2-wire 24V dc actuators in a smoke control and/or environmental ventilation system.

The controller provides up to 16A of output power across a minimum of 2 radial circuits (up to a maximum of 4) with 1 control zone input.

Operating from a 230V ac 13A supply, the OS2 SHEVTEC 1 Zone 16A Controller can deliver up to 16A to drive 24V motorised actuators and magnetic catches. Battery backup is provided for continued operation after mains supply interruption (batteries not included)

OS2 SHEVTEC 1 Zone 16A Controller can be mounted locally to the devices to be operated or in a centralised location. Each OS2 SHEVTEC 1 Zone 16A Controller can operate independently or can be linked to others to produce a networked control system. The networked control system in turn can operate standalone or be linked to a building management system.

This product may be specified to meet a specfic application. Please contact our sales team to discuss your application.

Voce di capitolato
  • Power

    Supply 230 V ac 50/60 Hz from a 13 A supply

    Output nominal 24 V dc multi-channel output not to exceed 8A per channel for 60 seconds. Peak current combined output can exceed 16A for a short duration

    Backup battery 4 x 12 V dc 7Ah sealed lead-acid batteries (not included)***

    Battery standby time 72 hours with maximum 40mA standby drain on PER permanent*

    Expected battery life 3+ years @ 25°C

    Real time clock battery life is 10 years

    Environment

    IP rating 30

    Humidity range 10 to 90% Non-condensing

    Storage -20 to +50°C

    Operating temperature -5 to 40°C**

    Miscellaneous

    Dimensions 600 x 400 x 250mm

    Cable entry is via 32 x 20mm top mounted cable glands

    Internal temperature sensor installed to provide optimal battery charging compensation as the ambient temperature changes.

    LED Status Indicators and Mains Isolator

    * Standby drain current comprises of enabled fire inputs, communication cards, and other loads connected to PER.
    ** Operation at elevated temperatures may reduce battery life.
    *** 4 Required

Specifiche tecniche
  • Rif. UnicoSECBIM0004
  • Famiglia di prodottoControl Systems
  • Gruppo di famigliaController
  • TipoOggetto (oggetto singolo)
  • Data di pubblicazione2016-05-26
  • Numero di versione1
  • Altezza (mm)600
  • Larghezza (mm)400
  • Profondità (mm)250
Relativo a
  • Materiale principaleAcciaio
  • Progettato inRegno Unito
  • Prodotto inRegno Unito
Classificazioni
  • Categoria BIMobjectImpianti elettrici - Controllo accessi
  • Clasificazione IFCComando
  • Codice Uniclass 2015Pr_75_50_18
  • Descrizione Uniclass 2015Controllers and control panels
Proprietà
  • Electrical - Controls
    ApplicationEnvironmental Ventilation Smoke Ventilation
    Current13 A
    Depth128.4 mm
    Frequency50 Hz - 60 Hz
    Height600 mm
    Length400 cm
    MaterialSteel
    Number Of Ports32
    Voltage230 V
    Width250 mm
  • UK.COBie.Component
    Length400 cm
  • UK.COBie.Type
    MaterialSteel

Disponibilità Regionale

Europa Asia Nord America Africa Sud America Oceania
Albania
Afghanistan
Anguilla
Algeria
Argentina
Australia
Andorra
Arabia Saudita
Antigua e Barbuda
Angola
Bolivia
Figi
Austria
Armenia
Aruba
Benin
Brasile
Guam
Belgio
Azerbaijan
Bahamas
Botswana
Cile
Isola Norfolk
Bielorussia
Bahrein
Barbados
Burkina Faso
Colombia
Isole Cook
Bosnia ed Erzegovina
Bangladesh
Belize
Burundi
Ecuador
Isole Marianne Settentrionali
Bulgaria
Bhutan
Bermuda
Camerun
Guiana Francese
Isole Marshall
Cipro
Brunei
Canada
Capo Verde
Guyana
Isole Minori Esterne degli Stati Uniti
Città del Vaticano
Cambogia
Costa Rica
Ciad
Isole Falkland (Malvine)
Isole Pitcairn
Croazia
Cina
Curaçao
Comore
Paraguay
Isole Salomone
Danimarca
Corea del Nord
Dominica
Congo
Perù
Kiribati
Estonia
Corea del Sud
El Salvador
Costa d'Avorio
Suriname
Nauru
Finlandia
Emirati Arabi Uniti
Giamaica
Egitto
Uruguay
Niue
Francia
Filippine
Grenada
Eritrea
Venezuela
Nuova Caledonia
Germania
Georgia
Groenlandia
eSwatini
Nuova Zelanda
Gibilterra
Giappone
Guadalupa
Etiopia
Palau
Grecia
Giordania
Guatemala
Gabon
Papua Nuova Guinea
Guernsey
Hong Kong
Haiti
Gambia
Polinesia Francese
Irlanda
India
Honduras
Ghana
Samoa
Islanda
Indonesia
Isole BES
Gibuti
Samoa Americane
Isola di Man
Iran
Isole Cayman
Guinea
Stati Federati di Micronesia
Isole Åland
Iraq
Isole Turks e Caicos
Guinea Equatoriale
Timor Est
Isole Faroe
Isola di Natale
Isole Vergini Americane
Guinea-Bissau
Tokelau
Italia
Isole Cocos (Keeling)
Isole Vergini britanniche
Kenya
Tonga
Jersey
Israele
Martinica
Lesotho
Tuvalu
Lettonia
Kazakistan
Messico
Liberia
Vanuatu
Liechtenstein
Kirghizistan
Montserrat
Libia
Wallis e Futuna
Lituania
Kuwait
Nicaragua
Madagascar
Lussemburgo
Laos
Panamá
Malawi
Macedonia del Nord
Libano
Porto Rico
Mali
Malta
Macau
Repubblica Dominicana
Marocco
Moldavia
Maldive
Saint Kitts e Nevis
Mauritania
Monaco
Malesia
Saint Martin
Mauritius
Montenegro
Mongolia
Saint Vincent e Grenadine
Mayotte
Norvegia
Myanmar (Burma)
Saint-Barthélemy
Mozambico
Paesi Bassi
Nepal
Saint-Pierre e Miquelon
Namibia
Polonia
Oman
Santa Lucia
Niger
Portogallo
Pakistan
Sint Maarten
Nigeria
Regno Unito
Palestina
Stati Uniti
Repubblica Centrafricana
Repubblica Ceca
Qatar
Trinidad e Tobago
Repubblica Democratica del Congo
Romania
Singapore
Riunione
Russia
Siria
Ruanda
San Marino
Sri Lanka
Sahara Occidentale
Serbia
Tagikistan
Sant'Elena
Slovacchia
Tailandia
São Tomé e Príncipe
Slovenia
Taiwan
Senegal
Spagna
Territori Britannici dell'Oceano Indiano
Seychelles
Svalbard e Jan Mayen
Turchia
Sierra Leone
Svezia
Turkmenistan
Somalia
Svizzera
Uzbekistan
Sudafrica
Ucraina
Vietnam
Sudan
Ungheria
Yemen
Sudan del Sud
Tanzania
Togo
Tunisia
Uganda
Zambia
Zimbabwe