Pubblica i tuoi prodotti
FT-3400 Insertion Electromagnetic Flow Meter

FT-3400 Insertion Electromagnetic Flow Meter

ONICON's FT-3400 Series Insertion Electromagnetic Flow Meters are suitable for measuring electrically conductive liquids in a wide variety of applications. Each FT-3400 provides a single analog output for flow rate, a high resolution frequency output to drive peripheral devices, a scalable pulse output for totalization, and an empty pipe alarm. It is available for use in pipes ranging in size from 1¼" to 72" in diameter. The FT-3400 Insertion Electromagnetic Flow Meter features ONICON's unique hot tap design that allows for easy insertion or removal from the pipe without the use of special tools and without disrupting flow. The low maintenance design is provided ready-to-use without the need for field programming. 

Typical Applications

The FT-3400 is ideal for chilled water, hot water, domestic water, condenser water and municipal water applications.

Standard Features

Highly Accurate - Each flow meter is individually wet calibrated and accurate to within ± 1.0% of reading.

Simple Installation and Commissioning - Each flow meter is factory programmed and ready for use upon delivery.

Low Maintenance - No moving parts and durable construction provide years of maintenance-free service.

Voce di capitolato
  • Basis of Design: ONICON Model F-3500 Series Insertion Electromagnetic Flowmeter. Manufacturers approved to bid, subject to compliance with requirements include:

    Insert additional MFG’s pre-approved to bid.

    Description: Provide an insertion electromagnetic flowmeter complete with NIST traceable, wet calibrated flow-measuring element, integral transmitter, installation valves, installation depth gage and calibration certificate. Flowmeter shall be wet tappable, allowing insertion and removal from the flow stream without system shutdown.

    Application Range: This contractor shall be responsible for selecting the flowmeter options submitted based on the application, refer to section for 230519.3.4 “Flowmeter Schedule by Application”. Flowmeter shall be constructed, calibrated and scaled for the intended application in terms of pipe size, pipe material, installation requirements, expected flow rate, ambient conditions and fluid characteristics which include but are not limited to pressure, temperature, conductivity and viscosity.

    Sensing Technology: Electromagnetic velocity-measuring element.

    Design: Electromagnetic sensing element shall utilize two sets of diametrically opposed electrodes to measure the average flow rate velocity.

    Construction: Wetted components shall be constructed of 316L stainless steel with attached tag indicating calibration information.

    Maximum Pressure Rating: 400 psig.

    Maximum Temperature Rating: 200 deg F.

    End Connections for NPS 1.25” and Larger: 1” Male NPT Hot Tap Adapter fitting. Installation through 1” full port isolation valve, minimum.

    Flow Range: Flow-measuring element and transmitter shall cover operating range of equipment or system served.

    Accuracy: Flowmeter shall provide calibrated outputs directly from the integral transmitter, throughout the operating range with the accuracy stated as follows:

    Plus or minus 1.0% of rate from 2.0 to 20.0 ft/sec velocity (10:1 turndown).

    Plus or minus 0.02 ft/sec below 2 ft / sec

    Calibration: Each flowmeter shall receive a wet calibration, within the expected operating range, against a primary volumetric standard that is traceable to NIST.

    Optional Local Display: Local display shall provide instantaneous flow rate information and totalized flow information and shall be factory configured for connection to a specific flowmeter.

    Operating and Installation Instructions: Installation and operating instructions shall be provided for each flowmeter. Refer to section 230519.3.4 “Flowmeter Schedule by Application” for additional installation requirements.

    Warranty: Each flowmeter shall be covered by the manufacturer’s three-year warranty.

Specifiche tecniche
  • Rif. Unicoft-3400-series-insertion-electromagnetic-flow-meter
  • Famiglia di prodottoFlow and Energy Measurement
  • Gruppo di famigliaElectromagnetic Flow Meters
  • TipoOggetto (oggetto singolo)
  • Data di pubblicazione2023-11-02
  • Numero di versione1
Relativo a
  • Progettato inStati Uniti
  • Prodotto inStati Uniti
Classificazioni
  • Categoria BIMobjectRiscaldamento, ventilazione e condizionamento - HVAC - Altro
  • Codice ETIMEC010582
  • Nome ETIMElectromagnetic liquid flow meter
  • Codice Uniclass 2015Pr_80_51_46_27
  • Descrizione Uniclass 2015Electromagnetic flow meters
  • Codice CSI MasterFormat 201440 71 00
  • Titolo CSI MasterFormat 2014Flow Measurement
  • Numero OmniClass23-27 11 15
  • Titolo OmniClassFlow Measuring Instrument And Controls

Disponibilità Regionale

Nord America
Anguilla
Antigua e Barbuda
Aruba
Bahamas
Barbados
Belize
Bermuda
Canada
Costa Rica
Cuba
Curaçao
Dominica
El Salvador
Giamaica
Grenada
Groenlandia
Guadalupa
Guatemala
Haiti
Honduras
Isole BES
Isole Cayman
Isole Turks e Caicos
Isole Vergini Americane
Isole Vergini britanniche
Martinica
Messico
Montserrat
Nicaragua
Panamá
Porto Rico
Repubblica Dominicana
Saint Kitts e Nevis
Saint Martin
Saint Vincent e Grenadine
Saint-Barthélemy
Saint-Pierre e Miquelon
Santa Lucia
Sint Maarten
Stati Uniti
Trinidad e Tobago