KESSEL-lifting station Aqualift S Compact,Duo,GTF1200,floor slab

KESSEL-lifting station Aqualift S Compact,Duo,GTF1200,floor slab

Lifting station Aqualift S Compact Mono Tronic Duo version with two pumps with black cover 1200-S3 Pump volume: 20 liters Polyethylene storage chamber for installation in a concrete slab/floor, installation depth (D) 490 to 620 mm, with lateral inlet Ø 110 mm. Installation area 700 × 700 mm. Upper section and cover Vertically and laterally adjustable upper section, with black / recessed cover for on-site tiling, integrated drain, made of polymer, load class K 3, with moisture protective sealing flange. Pump Single or twin removable GTF pump(s) for wastewater without sewage, float switch / air pressure sensor controlled with multi-vane impeller, with integrated non-return flap, pumping volume 20 liters (GTF 500 / GTF 1200), pressure pipe connection Ø 40 mm. Control unit Tronic versions with SDS control unit (self-diagnosis system) for fully automatic pump control, splash water protected (IP 54), wall mounted. Power cable length: 5 m Note: A ventilation pipe must be provided for on site. Accessories: page 115 • Type of system: twin pump station • Colour: black • Type of wastewater: non-faecal wastewater • Installation: within the building - installation in the concrete floor slab • Standard: EN 12050-2 • Type of cover: cover plate with cover • Cover colour: black • Locking: yes • Load class: K3 • Length: 617 mm • Width: 585 mm • Installation depth T: 490mm - 620 mm • Inlet nominal size: DN100 • Pressure pipe connection (DN): 32 • Pressure pipe connection (outer diameter): 40 mm • Free passage: 30 mm • Backflow preventer: integrated • Useful volume: approx. 20 l • Net weight: 23 kg • Pump type: GTF1200 • Number of pumps: 2 • Impeller type: multi-vane vortex impeller • Pump control: control unit • Control unit: Comfort • Self-diagnosis system (SDS): yes • Battery backup: yes • Multi-line display: yes • Logbook function: yes • USB interface: yes • GSM interface: yes • Potential-free contact: optional • Length of control unit mains cable: 1.4 m • Control unit degree of protection: IP 54 • Alarm sensor: optical probe • Type of level recording: pneumatic • Pumping capacity: max. 15.5 m³/h • Pumping height: max. 9 m • Pumped medium temperature, continuous (max.): 35 °C • Nominal power (P2): 0.84 kW • Input power (P1): 1.40 kW • Operating voltage: 230 V DS • Nominal frequency: 50 Hz • Speed: 2650 1/min • Nominal current: 6.2 A • Fusing: C 16 A • Degree of protection (pump): IP 68 (3m water head) • Operating mode: S3 • Over heat switch: integrated • Length of pump mains cable: 5 m • Type of pump connection cable: H07RN-F 3G 1.0 mm² • Electrical connection type: coded plug
Voce di capitolato
  • • Coverage features • Type of cover: cover plate with slotted grid • Cover material: plastic • Cover color: black • Load class: K 3 (EN 1253-1) • Length: 366 mm • Width: 366 mm • Locking: Lock & Lift • Dimensions • Length: 617 mm • Width: 585 mm • general characteristics • Color: Black • Standard: EN 12050-2 • execution • System type: double system • Pump control: switchgear • Backflow preventer: integrated • container • Pressure outlet (DA): 40 mm • Pressure outlet (DN): 32 mm • Installation depth: 490-620mm • Usable volume: 20 l • Inlet nominal diameter (DN): 100 mm • Conveyor • Pump: GTF 1200 • Number of pumps: 2 • Delivery head max .: 9 m • Delivery rate max .: 15.5 m3 / h • Operating voltage: 230 V • Mains frequency: 50 Hz • Operating mode: S3 - 10% • Power P1: 1.4 kW • Power P2: 0.84 kW • Speed: 2,650 rpm • Required fuse protection (line protection): C 16 A • Material temperature (permanent) max .: 40 ° C • Connection type: coded connector • Impeller type: Vortex impeller • Length of mains connection line pump: 5 m • Nominal current: 6.2 A. • Protection class pump: IP 68 (3m) • Type of connection line pump: H07RN-F 3G 1.0 mm2 • control • Switching device: Comfort • Operating voltage: 230 V • Mains frequency: 50 Hz • Self-diagnosis system (SDS): yes • Battery backup: yes • Multi-line display: yes • Log book function: yes • USB interface: yes • GSM interface: yes • Potential-free contact: optional • Protection class switching device: IP 54 • Connection type: coded connector • Length of mains connection cable for switching device: 1.4 m • Type of level detection: pneumatic • Level detection instrument: immersion tube • Alarm transmitter: optical probe • Other features • Type of waste water: free of faeces • Wastewater volume: medium • Type of height adjustment: telescopic top section • Delivery condition: ready for installation (connecting parts must be connected on site) • CE marking: yes • Installation situation: installation in the base plate • Free passage: 30 mm • Gross weight: 24.297 kg • Net weight: 22.797 kg
Specifiche tecniche
  • Rif. Unico281230S
  • Famiglia di prodottoAqualift S underfloor
  • Gruppo di famigliaPump technology - Standard products
  • TipoOggetto (oggetto singolo)
  • Data di pubblicazione2021-03-19
  • Numero di versione1
  • Larghezza (mm)585
Relativo a
  • Materiale principalePolietilene
  • Materiale secondarioPlastica
  • Progettato inGermania
  • Prodotto inGermania
  • Peso Netto (Kg)23
Classificazioni
  • Categoria BIMobjectImpianto idraulico - Pompe
  • Clasificazione IFCOggetto

Disponibilità Regionale

Europa Asia Nord America Africa Sud America Oceania
Albania
Afghanistan
Anguilla
Algeria
Argentina
Australia
Andorra
Arabia Saudita
Antigua e Barbuda
Angola
Bolivia
Figi
Austria
Armenia
Aruba
Benin
Brasile
Guam
Belgio
Azerbaijan
Bahamas
Botswana
Cile
Isola Norfolk
Bielorussia
Bahrein
Barbados
Burkina Faso
Colombia
Isole Cook
Bosnia ed Erzegovina
Bangladesh
Belize
Burundi
Ecuador
Isole Marianne Settentrionali
Bulgaria
Bhutan
Bermuda
Camerun
Guiana Francese
Isole Marshall
Cipro
Brunei
Canada
Capo Verde
Guyana
Isole Minori Esterne degli Stati Uniti
Città del Vaticano
Cambogia
Costa Rica
Ciad
Isole Falkland (Malvine)
Isole Pitcairn
Croazia
Cina
Cuba
Comore
Paraguay
Isole Salomone
Danimarca
Corea del Nord
Curaçao
Congo
Perù
Kiribati
Estonia
Corea del Sud
Dominica
Costa d'Avorio
Suriname
Nauru
Finlandia
Emirati Arabi Uniti
El Salvador
Egitto
Uruguay
Niue
Francia
Filippine
Giamaica
Eritrea
Venezuela
Nuova Caledonia
Germania
Georgia
Grenada
eSwatini
Nuova Zelanda
Gibilterra
Giappone
Groenlandia
Etiopia
Palau
Grecia
Giordania
Guadalupa
Gabon
Papua Nuova Guinea
Guernsey
Hong Kong
Guatemala
Gambia
Polinesia Francese
Irlanda
India
Haiti
Ghana
Samoa
Islanda
Indonesia
Honduras
Gibuti
Samoa Americane
Isola di Man
Iran
Isole BES
Guinea
Stati Federati di Micronesia
Isole Åland
Iraq
Isole Cayman
Guinea Equatoriale
Timor Est
Isole Faroe
Isola di Natale
Isole Turks e Caicos
Guinea-Bissau
Tokelau
Italia
Isole Cocos (Keeling)
Isole Vergini Americane
Kenya
Tonga
Jersey
Israele
Isole Vergini britanniche
Lesotho
Tuvalu
Lettonia
Kazakistan
Martinica
Liberia
Vanuatu
Liechtenstein
Kirghizistan
Messico
Libia
Wallis e Futuna
Lituania
Kuwait
Montserrat
Madagascar
Lussemburgo
Laos
Nicaragua
Malawi
Macedonia del Nord
Libano
Panamá
Mali
Malta
Macau
Porto Rico
Marocco
Moldavia
Maldive
Repubblica Dominicana
Mauritania
Monaco
Malesia
Saint Kitts e Nevis
Mauritius
Montenegro
Mongolia
Saint Martin
Mayotte
Norvegia
Myanmar (Burma)
Saint Vincent e Grenadine
Mozambico
Paesi Bassi
Nepal
Saint-Barthélemy
Namibia
Polonia
Oman
Saint-Pierre e Miquelon
Niger
Portogallo
Pakistan
Santa Lucia
Nigeria
Regno Unito
Palestina
Sint Maarten
Repubblica Centrafricana
Repubblica Ceca
Qatar
Stati Uniti
Repubblica Democratica del Congo
Romania
Singapore
Trinidad e Tobago
Riunione
Russia
Siria
Ruanda
San Marino
Sri Lanka
Sahara Occidentale
Serbia
Tagikistan
Sant'Elena
Slovacchia
Tailandia
São Tomé e Príncipe
Slovenia
Taiwan
Senegal
Spagna
Territori Britannici dell'Oceano Indiano
Seychelles
Svalbard e Jan Mayen
Turchia
Sierra Leone
Svezia
Turkmenistan
Somalia
Svizzera
Uzbekistan
Sudafrica
Ucraina
Vietnam
Sudan
Ungheria
Yemen
Sudan del Sud
Tanzania
Togo
Tunisia
Uganda
Zambia
Zimbabwe