Pubblica i tuoi prodotti
Commercial Indoor/Outdoor Tankless Water Heater
Commercial Indoor/Outdoor Tankless Water Heater

    Commercial Indoor/Outdoor Tankless Water Heater

    4.5 su 5 stelle4.5(14 recensioni)

    Ultra-Low NOx gas tankless water heaters with condensing technology featuring up to
    0.95 Uniform Energy Factor (UEF) which lowers operating costs and is environmentally
    friendly.



    Voce di capitolato
    • TANKLESS CONDENSING HIGH EFFICIENCY SPECIFICATIONS

      The fully modulating, on-demand, condensing gas fired tankless water heater(s) shall be A.O. Smith model CT-199, having a maximum input
      rating of 199,000 Btu/h and available in NG or LP. The heater shall have ¾ in. male NPT water and gas connections. The inlet gas supply
      pressures shall be 4.0 in. WC (min.) up to 10.5 in. WC (max) for NG and 8.0 in. WC (min.) up to 14 in. WC (max.) for LP. The indoor heater(s)
      shall incorporate an integrated temperature controller that will provide diagnostic information, fault history, and heater set temperature. The
      outdoor heater(s) shall be factory supplied with a temperature remote, 100112572, that can be installed up to 400 ft. from the heater using
      18 gauge (minimum) control wire. The temperature remote shall provide diagnostic information, fault history, and heater set temperature. The
      heater(s) shall operate using 120 V / 60 Hz power source. The indoor heater(s) will incorporate a factory installed power cord.
      The indoor heater(s) shall be vented with 3” or 4” diameter schedule 40 PVC, CPVC, ABS, or Category IV vent pipe with a length not to exceed
      70 ft. (equivalent) for 3” vent or 100 ft. (equivalent) for 4” vent, terminating horizontally or vertically. The intake pipe may use material such
      as PVC, ABS, aluminum, or Category IV pipe and cannot exceed 70 ft. (equivalent) for 3” vent or 100 ft. (equivalent) for 4” vent. The outdoor
      heater(s) shall be constructed with an integral exhaust vent on the front of the heater.
      The water heater(s) shall use a commercial-grade copper, fin tube primary heat exchanger with quick release brass or bronze waterways. The
      secondary heat exchanger shall be constructed from stainless steel 316L. The heater(s) shall be controlled by an on-board solid-state printed
      circuit board which uses the following factory installed components: thermistors to monitor water temperature and exhaust temperature; a flow
      sensor to measure flow rate; a flame sensor to monitor combustion; an Air-Fuel Ratio Rod to measure and adjust air input in order to maintain
      optimal combustion efficiency. The heater also consists of in-line fusing and surge absorbers for electrical surge protection, an electronic spark
      igniter, aluminized stainless steel burners, hi-limit temperature switches to monitor water and exhaust temperatures, modulating gas valve,
      dual freeze protection that will automatically fire the heater (indoor model only) and use heating blocks to protect the heat exchanger, and an
      overheat cutoff fuse.
      The heater(s) can manifold to Easy-Link up to 4 heaters to provide additional capacity. The Easy-Link controls shall be built onto the on-board
      solid state printed circuit board and does not require external controls. The linking control wire shall be supplied with the heater. The heater(s)
      can use a Multi-Unit controller, 100112691, to manifold 5-20 heaters. The Easy-Link and Multi-Unit Controller shall modulate the system for the
      most efficient performance. The Easy-Link and Multi-Unit Controller shall rotate the priority heater every 12 hours of operation time or 100 starts
      for balanced duty/cycle operation.
      The heater models are design certified by CSA according to ANSI Z21.10.3 · CSA 4.3, approved for sale in the United States, ENERGY STAR®
      qualified, has a minimum uniform energy factor of 0.93, meets the energy efficiency requirements of the U. S. Department of Energy and ASHRAE
      90.1, complies with SCAQMD Rule 1146.2 and other air quality districts with similar requirements for low NOx emissions of 14 ng/J or 20 ppm,
      and shall be certified to NSF 5 standards.

    Specifiche tecniche
    • Rif. Unicoaosmith_CT-199
    • Famiglia di prodottoCommercial Tankless Water Heater
    • Gruppo di famigliaTankless
    • TipoOggetto (oggetto singolo)
    • Data di pubblicazione2019-10-18
    • Numero di versione1
    Relativo a
    • Materiale principaleRame
    • Materiale secondarioAcciaio inossidabile
    • Progettato inGiappone
    • Prodotto inGiappone
    Classificazioni
    • Categoria BIMobjectRiscaldamento, ventilazione e condizionamento - Scaldabagno
    • Codice ETIMEC000392
    • Nome ETIMInstantaneous water heater
    • Codice Uniclass 2015Pr_60_60_96_33
    • Descrizione Uniclass 2015Gas-fired instantaneous water heaters
    • Codice CSI MasterFormat 201422 34 13
    • Titolo CSI MasterFormat 2014Instantaneous, Tankless, Gas Domestic Water Heaters
    • Numero OmniClass23-31 29 11 13
    • Titolo OmniClassGas Instantaneous Hot Water Heaters
    • Codice CSI UniFormat IID3090
    • Titolo CSI UniFormat IIOther HVAC Systems & Equipment

    Disponibilità Regionale

    Nord America
    Anguilla
    Antigua e Barbuda
    Aruba
    Bahamas
    Barbados
    Belize
    Bermuda
    Canada
    Costa Rica
    Cuba
    Curaçao
    Dominica
    El Salvador
    Giamaica
    Grenada
    Groenlandia
    Guadalupa
    Guatemala
    Haiti
    Honduras
    Isole BES
    Isole Cayman
    Isole Turks e Caicos
    Isole Vergini Americane
    Isole Vergini britanniche
    Martinica
    Messico
    Montserrat
    Nicaragua
    Panamá
    Porto Rico
    Repubblica Dominicana
    Saint Kitts e Nevis
    Saint Martin
    Saint Vincent e Grenadine
    Saint-Barthélemy
    Saint-Pierre e Miquelon
    Santa Lucia
    Sint Maarten
    Stati Uniti
    Trinidad e Tobago