Pubblica i tuoi prodotti
High Intensity Infrared Heater, Model KMI

High Intensity Infrared Heater, Model KMI

The Series KMI, High Efficiency Infrared Heater has a radiant efficiency of up to 81%! It's energy-saving reflector hoods, double gas nozzle, and removable combustion chamber are only a few features that make this infrared heater stand out against its competition.

  • Energy-saving reflector hoods with 100% Max Fiber insulation
  • New 'high-grid' technology ensures further optimization of the radiant yield
  • Increased radiant efficiency of up to 81%
  • Optimized cold start and wasted gas behaviour
  • Increased efficiency through maximum preheating of the mixture
  • Logistic advantage through consistent application of the modular system
  • Adjustable reflector plates allow for individual adjustment to fit the needs of the application
  • Reduction of maintenance costs due to the easy removal of the combustion chamber
Voce di capitolato
  • Assemblies shall be CSA approved High-intensity heaters to ANS1 Z83.19 (latest revision) and CSA 2.35 (latest revision). Approval shall include components of the complete heater, including burners, reflectors, accessories, thermostats, and associated controls and specifications. Installations of units shall comply with local building codes, or in their absence, the latest edition of the national regulations and procedures listed below. Heaters shall be electrically grounded in accordance with the National Electric Code, ANSI/NFPA 70 in the US, and the Canadian Electric Code, CSA C22.1 in Canada, and shall comply with all local requirements. Heaters shall be installed only for use with the type of gas appearing on the rating plate, and the installation shall conform to the National Fuel Gas Code, ANSI Z223.1 (NFPA 54) in the US and the Natural Gas and Propane Installation Codes, CAN/CGA B 149.1 & B149.2 in Canada. The Manufacturer warrants to the original owner that the product will be free of defects in material and workmanship. For the Series KMI, the warranty for all components except for the ceramic burner head assembly is limited to 24 months from the date of installation. The ceramic burner head assembly shall be warranted for an additional 8 years for units that are proven to the satisfaction of the manufacturer to be inoperative due to defects in material or workmanship.

    Basis-of-Design Product shall be Superior Radiant Products Model KMI Series high-efficiency high-intensity type gas-fired radiant infrared heaters with firing rates as called for in the contract documents within the range of 21 MBH to 125 MBH. CSA approved complete with single body burner head, ignition control, valve & gas pressure switch. Heaters must provide a radiant factor of at least 81% as tested to EN 419-2 standard and provide documentation upon request and shall cover the entire infrared spectrum – from short to long wavelengths at a minimum gas inlet pressure of 6.5 inches W.C. (natural gas) and 12 inches W.C. (propane). Maximum inlet pressure for both fuel types is 14 inches W.C. The unit shall draw no more than 20 VA at either 24 VAC or 120VAC, 60Hz. The heater shall perform controlled and clean surface combustion. The resulted quantity of noxious components CO and NOx shall be CO:  20 – 200 ppm; NOx: 4 – 10 ppm. Heater body shall comprise of Burner-head (mixing chamber, ceramic emitter tiles, and steel mesh), outer body, and reflector assemblies. Burner head shall be stainless steel venturi placed inside insulated reflector housing and shall provide for pre-heat of the air-fuel mixture to achieve higher efficiency. Ignition shall be a solid-state direct spark and make a minimum of 3 ignition attempts before lockout. Ignition shall have openly accessible sense current contacts. Gas valve shall include a manual valve, two magnetic operators, and a standard gas pressure regulator and have pressure taps to measure inlet and manifold pressures. Controls shall incorporate a gas pressure switch capable of shutting off power to the ignition module in case of inlet gas pressure drops below the minimum requirement.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project. 

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 81% radiant factor.
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with a new system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model.
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Specifiche tecniche
  • Rif. Unicokmi
  • Famiglia di prodottoHigh Intensity Heaters
  • Gruppo di famigliaHigh Efficiency - Series KMI
  • TipoOggetto (oggetto singolo)
  • Data di pubblicazione2021-02-16
  • Numero di versione1
Relativo a
  • Materiale principaleAlluminio
  • Materiale secondarioCeramica
  • Progettato inCanada
  • Prodotto inCanada
Classificazioni
  • Categoria BIMobjectRiscaldamento, ventilazione e condizionamento - Riscaldatori e radiatori
  • Clasificazione IFCStufa
  • Nome UNSPSCSpace heaters
  • Codice UNSPSC40101819
  • Codice Uniclass 2015Pr_70_60_36_70
  • Descrizione Uniclass 2015Radiant luminous heaters
  • Codice CSI MasterFormat 201423 55 23
  • Titolo CSI MasterFormat 2014Gas-Fired Radiant Heaters
  • Numero OmniClass23-33 15 17 13
  • Titolo OmniClassFuel Fired HVAC Radiant Heaters
  • Codice CSI UniFormat IID3090
  • Titolo CSI UniFormat IIOther HVAC Systems & Equipment

Disponibilità Regionale

Europa Nord America Asia
Albania
Anguilla
Armenia
Andorra
Antigua e Barbuda
Azerbaijan
Austria
Aruba
Bangladesh
Belgio
Bahamas
Bhutan
Bielorussia
Barbados
Brunei
Bosnia ed Erzegovina
Belize
Cambogia
Bulgaria
Bermuda
Cina
Cipro
Canada
Corea del Nord
Città del Vaticano
Costa Rica
Corea del Sud
Croazia
Cuba
Filippine
Danimarca
Curaçao
Georgia
Estonia
Dominica
Giappone
Finlandia
El Salvador
Hong Kong
Francia
Giamaica
India
Germania
Grenada
Indonesia
Gibilterra
Groenlandia
Isola di Natale
Grecia
Guadalupa
Isole Cocos (Keeling)
Guernsey
Guatemala
Kazakistan
Irlanda
Haiti
Kirghizistan
Islanda
Honduras
Laos
Isola di Man
Isole BES
Macau
Isole Åland
Isole Cayman
Maldive
Isole Faroe
Isole Turks e Caicos
Malesia
Italia
Isole Vergini Americane
Mongolia
Jersey
Isole Vergini britanniche
Myanmar (Burma)
Lettonia
Martinica
Nepal
Liechtenstein
Messico
Pakistan
Lituania
Montserrat
Singapore
Lussemburgo
Nicaragua
Sri Lanka
Macedonia del Nord
Panamá
Tagikistan
Malta
Porto Rico
Tailandia
Moldavia
Repubblica Dominicana
Taiwan
Monaco
Saint Kitts e Nevis
Territori Britannici dell'Oceano Indiano
Montenegro
Saint Martin
Turkmenistan
Norvegia
Saint Vincent e Grenadine
Uzbekistan
Paesi Bassi
Saint-Barthélemy
Vietnam
Polonia
Saint-Pierre e Miquelon
Portogallo
Santa Lucia
Regno Unito
Sint Maarten
Repubblica Ceca
Stati Uniti
Romania
Trinidad e Tobago
Russia
San Marino
Serbia
Slovacchia
Slovenia
Spagna
Svalbard e Jan Mayen
Svezia
Svizzera
Ucraina
Ungheria