High power condensing generator with wide modulation range for outdoor installation. Max output power in heating mode (50/30°C) 371 kW NOx class 6° Modulation range (Pmin/Pmax) 1/25 Max operated pressure 6 bar
Voce di capitolato
  • High-power condensing boiler, with high modulation range up to 1/40. Designed for installations both in technical rooms and outdoors without protection. Thermal group composed of a cascade of aluminium-silicon alloy elements designed for maximum efficiency and minimum pressure drops on the hydraulic circuit. Each unit is completed by the circulation group and the pre-mix combustion group. Total pre-mixing group, for micro-flame combustion with very low polluting emissions (class 6 in compliance with EN 15502-1). The metallic microfibre burner can run on natural gas or LPG Generator protection systems: * Double probe system (flow and return) to operate at constant ΔT (from 0 to 60°C) * Flue gas safety sensor * Water pressure switch with a minimum limit of 0.8 bar * Hydraulic unit with 3-way shut-off valve for discharge into the atmosphere and non-return valve on flow Air/Flue gas circuit with suction on the installation site and flue gas non-return clapet valve integrated on the suction group in order to size the flue gas manifold under pressure Control panel protected by a door integrated into the casing Four sturdy floating wheels installed as standard to facilitate unloading and mobility during installation. Adjustable feet for positioning. Designed to be installed both indoors and outdoors even without any protection from atmospheric agents (up to a temperature of -5°C). It can be connected to the system either on the right or on the left and it is delivered complete with blind flanges. In combination with THETA+ thermoregulation, it is possible to install more MACH generators in series (up to 8 units) * The MACH electronic control can manage a system with two direct zones and a DHW storage tank or more complex systems at different temperatures in combination with THETA+ thermoregulation. RANGE RATED certified generator to adapt the power generated to the needs of the system, to increase the efficiency of the system while preserving the mechanics of the machine from continuous switching on and off. The modules can be controlled and operated remotely: Power or temperature regulation with 0 - 10V signal Blocking alarm signal for safety and restoration of operation ModBus communication protocols (in combination with THETA+ thermoregulation)
Specifiche tecniche
  • Rif. UnicoMACH370450
  • Famiglia di prodottoHVAC - Boilers
  • Gruppo di famigliaBoilers
  • TipoOggetto (oggetto singolo)
  • Data di pubblicazione2022-05-12
  • Numero di versione1
  • Altezza (mm)1550
  • Larghezza (mm)1630
  • Profondità (mm)710
Relativo a
  • Materiale principaleMetallo
  • Materiale secondarioPlastica
  • Progettato inItalia
  • Prodotto inItalia
  • Peso Netto (Kg)360
Classificazioni
  • Categoria BIMobjectRiscaldamento, ventilazione e condizionamento - Caldaie
  • Clasificazione IFCCaldaia
  • Numero OmniClass23-33 11 13
  • Titolo OmniClassCondensing Boilers

Disponibilità Regionale

Europa Asia Nord America Africa Sud America Oceania
Albania
Afghanistan
Anguilla
Algeria
Argentina
Australia
Andorra
Arabia Saudita
Antigua e Barbuda
Angola
Bolivia
Figi
Austria
Armenia
Aruba
Benin
Brasile
Guam
Belgio
Azerbaijan
Bahamas
Botswana
Cile
Isola Norfolk
Bielorussia
Bahrein
Barbados
Burkina Faso
Colombia
Isole Cook
Bosnia ed Erzegovina
Bangladesh
Belize
Burundi
Ecuador
Isole Marianne Settentrionali
Bulgaria
Bhutan
Bermuda
Camerun
Guiana Francese
Isole Marshall
Cipro
Brunei
Canada
Capo Verde
Guyana
Isole Minori Esterne degli Stati Uniti
Città del Vaticano
Cambogia
Costa Rica
Ciad
Isole Falkland (Malvine)
Isole Pitcairn
Croazia
Cina
Cuba
Comore
Paraguay
Isole Salomone
Danimarca
Corea del Nord
Curaçao
Congo
Perù
Kiribati
Estonia
Corea del Sud
Dominica
Costa d'Avorio
Suriname
Nauru
Finlandia
Emirati Arabi Uniti
El Salvador
Egitto
Uruguay
Niue
Francia
Filippine
Giamaica
Eritrea
Venezuela
Nuova Caledonia
Germania
Georgia
Grenada
eSwatini
Nuova Zelanda
Gibilterra
Giappone
Groenlandia
Etiopia
Palau
Grecia
Giordania
Guadalupa
Gabon
Papua Nuova Guinea
Guernsey
Hong Kong
Guatemala
Gambia
Polinesia Francese
Irlanda
India
Haiti
Ghana
Samoa
Islanda
Indonesia
Honduras
Gibuti
Samoa Americane
Isola di Man
Iran
Isole BES
Guinea
Stati Federati di Micronesia
Isole Åland
Iraq
Isole Cayman
Guinea Equatoriale
Timor Est
Isole Faroe
Isola di Natale
Isole Turks e Caicos
Guinea-Bissau
Tokelau
Italia
Isole Cocos (Keeling)
Isole Vergini Americane
Kenya
Tonga
Jersey
Israele
Isole Vergini britanniche
Lesotho
Tuvalu
Lettonia
Kazakistan
Martinica
Liberia
Vanuatu
Liechtenstein
Kirghizistan
Messico
Libia
Wallis e Futuna
Lituania
Kuwait
Montserrat
Madagascar
Lussemburgo
Laos
Nicaragua
Malawi
Macedonia del Nord
Libano
Panamá
Mali
Malta
Macau
Porto Rico
Marocco
Moldavia
Maldive
Repubblica Dominicana
Mauritania
Monaco
Malesia
Saint Kitts e Nevis
Mauritius
Montenegro
Mongolia
Saint Martin
Mayotte
Norvegia
Myanmar (Burma)
Saint Vincent e Grenadine
Mozambico
Paesi Bassi
Nepal
Saint-Barthélemy
Namibia
Polonia
Oman
Saint-Pierre e Miquelon
Niger
Portogallo
Pakistan
Santa Lucia
Nigeria
Regno Unito
Palestina
Sint Maarten
Repubblica Centrafricana
Repubblica Ceca
Qatar
Stati Uniti
Repubblica Democratica del Congo
Romania
Singapore
Trinidad e Tobago
Riunione
Russia
Siria
Ruanda
San Marino
Sri Lanka
Sahara Occidentale
Serbia
Tagikistan
Sant'Elena
Slovacchia
Tailandia
São Tomé e Príncipe
Slovenia
Taiwan
Senegal
Spagna
Territori Britannici dell'Oceano Indiano
Seychelles
Svalbard e Jan Mayen
Turchia
Sierra Leone
Svezia
Turkmenistan
Somalia
Svizzera
Uzbekistan
Sudafrica
Ucraina
Vietnam
Sudan
Ungheria
Yemen
Sudan del Sud
Tanzania
Togo
Tunisia
Uganda
Zambia
Zimbabwe