Pubblica i tuoi prodotti
Tornado
Tornado
    Arjo

    Tornado

    Tornado® Flusher Disinfector, Bedpanwasher Tornado is a high-powered flusher-disinfector with a wide range of standard and optional features to meet your infection control needs. Tornado’s automated operation features are designed to help reduce the risk of cross-contamination while delivering highly effective cleaning and disinfection results. Support touch-free operation routines with an optional IR sensor or foot pedal to open the door. The disinfection phase can be controlled by time and temperature, or by the chosen A₀ value, while the Pipe System Disinfection (PSD) feature disinfects the entire pipe and nozzle system at the end of each cycle. Tornado also offers the option to record or track disinfection records via printer or USB, and consumes exceptionally low amounts of water, energy and chemicals per cycle**, thereby reducing operating costs as well as the overall impact on the environment.
    Voce di capitolato
    • “Equipment specifically built to empty, wash, rinse, thermally disinfect and cool bedpans and urinals                                                                                                                                                                                                                                                                                                                                                 The Tornado™ system comprises of a series of high pressure water cycles delivered through strategically located fixed and rotating nozzles, followed by a steam phase. 

      Key features
      Easy to use - simply load, close and activate programme.
      A flexible design - choice of polymeric material or stainless steel for outer casing.
      9+2 - system includes nine fixed and two rotating nozzles to meet the highest cleaning requirements.
      Pipe System Disinfection (PSD) provides rapid disinfection through all fixed and rotating nozzles, disinfecting the entire pipe and nozzle system with every cycle.
      Smooth, hygienic chamber means no folds or pockets.
      Safe and rapid thermal disinfection of the goods with the steam transported into the chamber through all pipes and nozzles.
      Meets and exceeds the stringent cleaning and disinfection requirements of EN ISO15883 (CAN/CSA Z15883).
      Drying/cooling fan for rapid and hygienic dry and cooling of recepticles with HEPA filtered (H13) air.
      Deep-drawn stainless steel chamber without welded joints.
      Read out display provides the user with all information needed for operation and control.
      Remaining time displayed in an easy-to-follow cycle sequence.
      Ao value and control.
      Three programmes available: economy, normal and intensive, with 22 additional programmes available upon request.
      Optional automatic door function.
      Locking system during cycle, securing staff safety and ensuring a complete cleaning and disinfection process.
      Optional process records, via printer or USB.
      Environmentally friendly - low consumption of water and energy, recyclable material.
      Wide range of holders available for different receptacles.
      Lockable storage for detergent containers.
      Easy maintenance and service.“”
       

      Tornado - TECHNICAL DATA          
      UTILITY REQUIREMENTS          
      Utility Unit connection Supply Pressure requirements   Flow
      requirements   Comments  
      Cold Water (CW)   15 mm (G1/2") 100-800 kPa (1-8 bar, 14-116 PSi)   20 L/min   See notes 1 and 3 
      Hot Water (HW)  15 mm (G1/2")  100-800 kPa (1-8 bar, 14-116 PSi)    20 L/min    See notes 2 and 3 
      Drain (D)    Ø90 alt. Ø 110mm Not Applicable  Peak 1 L/sec  See notes 3 and 4
      Electrical (equipped with internal steam generator)           
      Voltage    Recommended service disconnect       Full load, Amps    See notes 5 and 6 
      L1, 230 VAC, 1N+PE, 50 Hz     Max. 3,0 kW, 1x Fuse C 16 A     13 A   
       L2, 230VAC, 3+PE, 50Hz     Max. 3,75 kW, 3x Fuse C 16 A     12 A   
        L3, 380-400VAC, 3N+PE, 50 HzA     Max. 3,75 kW, 3x Fuse C 10     9 A    
       L5, 240 VAC, 2+PE, 60 Hz     Max .3,3 kW, 2 x Fuse C 15 A     15 A    
       L6, 240VAC, 3+PE, 60 Hz      Max. 3,75 kW, 3x Fuse C 15 A    13 A   
       L9, 208 VAC, 2+PE, 60 Hz     Max. 3,0 kW, 2x Fuse C 15 A     14 A   
       L10, 208VAC, 3+PE, 60 Hz     Max. 3,75 kW, 3x Fuse C 15 A     13 A   
       L14, 200 VAC, 2+PE, 50 Hz      Max .3,0 kW, 2x Fuse C 16 A    15 A   
       L15, 200VAC, 3+PE, 50 Hz      Max. 3,75 kW, 3 x Fuse C 16 A    14 A   
       L18, 200 VAC, 2+PE, 60 Hz      Max. 3,0 kW, 2x Fuse C 16 A    15 A   
       L19, 200VAC, 3+PE, 60 Hz      Max. 3,75 kW, 3x Fuse C 16 A    15 A   
       L22, 230 VAC, 1N+PE, 60 Hz     Max. 3,0 kW, 1x Fuse C 16 A     13 A   
       L24, 380-400VAC, 3N+PE, 60 Hz      Max. 3,75 kW, 3x Fuse C 10 A    10 A   
       L28, 240 VAC, 1N+PE, 50 Hz      Max. 3,3 kW, 1x Fuse C 16 A    13,6 A   
       L30, 415VAC, 3N+PE, 50 Hz     Max. 3,75 kW, 3x Fuse C 10 A     9 A   
       OPERATING CONDITIONS       
       Room temperature     5-40°C (41-104F)       
       Air humidity     < 80% at 31°C (87° F)       
       Max surface temperature    40° C (104°F)       
      Water consumption          
       Economy program    11 liter ± 10 %*     
       * if option cooling/drying fan is selected for the cooling phase. If internal cooling is selected, additionally 3 liters ± 1 liter will be added to the stated consumption.

       Normal program    18 liter ± 10 %*  
       Intensive program    25 liter ± 10 %*  
      Chamber size and volume          
      Stainless steel 565x410x290, 67 liter          
      Noise level          
      Octave band(Hz)      

       125  250  500 1000   2000  4000  8000  LwA  LwAFmax The sound power level as
      linear octave band levels are
      presented as A-leveled sound
      power level, both LwA and
      LwAFmax. 
      Correction (Kok)      57  61 58  55    53 48    47  61  75
      Estimated LpA levels for Tornado located in a 70 m³ room, db ref 20 μPa.          
      Type of room     Description    Operator location *    3 m from washer  The calculated sound power
      levels are different LpA levels in
      different types of rooms. With
      bigger room volume the noise
      level is reduced and vice versa.
      Here are three examples of
      expected LpA levels.
      * See Note 7       
      Hard     All walls from concrete etc no
      absorbing elements.    60   60 
      Normal    Some sound
      absorbing elements
      like furniture and
      textiles.     56   55 
      Subdued    Some absorbing
      elements in ceiling
      and textiles.    53   51  
      Outer dimensions          
         Freestanding         See installation drawing in subsection
      installation.
              
       Width    450 mm (17" 11/16)      
       Depth    580 mm (22" 3/4)      
       Height    1320 mm (51" 7/8)      
       Weight    100 kg/220 lb       
      Notes

      1) Cold water recommended quality = potable water accordingly to WHO guidelines, temp. <20°C (<68°F).

      2) Hot water recommended quality = potable water accordingly to WHO guidelines, temp. 45-60°C (113-140°F).

      3) It shall be the Customers responsibility to eliminate water hammer conditions if they occur in the service piping.

      4) It shall be the Customers responsibility to provide a properly sixed and located drainage system in accordance with the national

      plumbing code. Consider that other equipment is tied to drain to eliminate slow drainage or backup.

      5) It shall be the Customers responsibility to complete all electrical connections using properly sized wiring in accordance with the

      national electrical code.

      6) It shall be the Customers responsibility to install an approved a fused disconnect switch accordingly to national code in all electrical

      supply lines at the washer disinfector location.

      7) LpA levels are measured to EN ISO 3747:2000, 1 meter in front of the washer and 1,5 meter above the floor level.

      Systems Available
      Freestanding with or without automatic door. 
      Accessories
      Arjo bedpan with lid.
      Drainage floor, Ø 3 ½ and Ø 4 1/4" (90 and 110 mm).
      Drainage wall, , Ø 3 ½ and Ø 4 1/4" (90 and 110 mm).
      Valves and filter.
      Arjo Clean Flusher Detergent, 5L canister.
      Arjo Clean Flusher Rinse, 5L canister.“”                                                      ”

    Specifiche tecniche
    • Rif. UnicoTornado
    • Famiglia di prodottoBed pan washer
    • Gruppo di famigliaDisinfection
    • TipoOggetto (oggetto singolo)
    • Data di pubblicazione2019-11-01
    • Numero di versione1
    • Altezza (mm)1320
    • Larghezza (mm)580
    • Profondità (mm)450
    Relativo a
    • Materiale principaleAcciaio inossidabile
    • Materiale secondarioPolymer
    • Progettato inSvezia
    • Prodotto inPolonia
    • Peso Netto (Kg)100
    Classificazioni
    • Categoria BIMobjectArticoli medici - Arredo ospedaliero
    • Clasificazione IFCMobilia
    • Nome UNSPSCFurniture and Furnishings
    • Codice UNSPSC56
    • Codice CSI MasterFormat 201412 54 00
    • Titolo CSI MasterFormat 2014Hospitality Furniture
    • Numero OmniClass23-21 11 00
    • Titolo OmniClassCommercial Furniture

    Disponibilità Regionale

    Europa Asia Nord America Africa Sud America Oceania
    Albania
    Afghanistan
    Anguilla
    Algeria
    Argentina
    Australia
    Andorra
    Arabia Saudita
    Antigua e Barbuda
    Angola
    Bolivia
    Figi
    Austria
    Armenia
    Aruba
    Benin
    Brasile
    Guam
    Belgio
    Azerbaijan
    Bahamas
    Botswana
    Cile
    Isola Norfolk
    Bielorussia
    Bahrein
    Barbados
    Burkina Faso
    Colombia
    Isole Cook
    Bosnia ed Erzegovina
    Bangladesh
    Belize
    Burundi
    Ecuador
    Isole Marianne Settentrionali
    Bulgaria
    Bhutan
    Bermuda
    Camerun
    Guiana Francese
    Isole Marshall
    Cipro
    Brunei
    Canada
    Capo Verde
    Guyana
    Isole Minori Esterne degli Stati Uniti
    Città del Vaticano
    Cambogia
    Costa Rica
    Ciad
    Isole Falkland (Malvine)
    Isole Pitcairn
    Croazia
    Cina
    Cuba
    Comore
    Paraguay
    Isole Salomone
    Danimarca
    Corea del Sud
    Curaçao
    Congo
    Perù
    Kiribati
    Estonia
    Emirati Arabi Uniti
    Dominica
    Costa d'Avorio
    Suriname
    Nauru
    Finlandia
    Filippine
    El Salvador
    Egitto
    Uruguay
    Niue
    Francia
    Georgia
    Giamaica
    Eritrea
    Venezuela
    Nuova Caledonia
    Germania
    Giappone
    Grenada
    eSwatini
    Nuova Zelanda
    Gibilterra
    Giordania
    Groenlandia
    Etiopia
    Palau
    Grecia
    Hong Kong
    Guadalupa
    Gabon
    Papua Nuova Guinea
    Guernsey
    India
    Guatemala
    Gambia
    Polinesia Francese
    Irlanda
    Indonesia
    Haiti
    Ghana
    Samoa
    Islanda
    Iran
    Honduras
    Gibuti
    Samoa Americane
    Isola di Man
    Iraq
    Isole BES
    Guinea
    Stati Federati di Micronesia
    Isole Åland
    Isola di Natale
    Isole Cayman
    Guinea Equatoriale
    Timor Est
    Isole Faroe
    Isole Cocos (Keeling)
    Isole Turks e Caicos
    Guinea-Bissau
    Tokelau
    Italia
    Israele
    Isole Vergini Americane
    Kenya
    Tonga
    Jersey
    Kazakistan
    Isole Vergini britanniche
    Lesotho
    Tuvalu
    Lettonia
    Kirghizistan
    Martinica
    Liberia
    Vanuatu
    Liechtenstein
    Kuwait
    Messico
    Libia
    Wallis e Futuna
    Lituania
    Laos
    Montserrat
    Madagascar
    Lussemburgo
    Libano
    Nicaragua
    Malawi
    Macedonia del Nord
    Macau
    Panamá
    Mali
    Malta
    Maldive
    Porto Rico
    Marocco
    Moldavia
    Malesia
    Repubblica Dominicana
    Mauritania
    Monaco
    Mongolia
    Saint Kitts e Nevis
    Mauritius
    Montenegro
    Myanmar (Burma)
    Saint Martin
    Mayotte
    Norvegia
    Nepal
    Saint Vincent e Grenadine
    Mozambico
    Paesi Bassi
    Oman
    Saint-Barthélemy
    Namibia
    Polonia
    Pakistan
    Saint-Pierre e Miquelon
    Niger
    Portogallo
    Palestina
    Santa Lucia
    Nigeria
    Regno Unito
    Qatar
    Sint Maarten
    Repubblica Centrafricana
    Repubblica Ceca
    Singapore
    Stati Uniti
    Repubblica Democratica del Congo
    Romania
    Sri Lanka
    Trinidad e Tobago
    Riunione
    Russia
    Tagikistan
    Ruanda
    San Marino
    Tailandia
    Sahara Occidentale
    Serbia
    Taiwan
    Sant'Elena
    Slovacchia
    Territori Britannici dell'Oceano Indiano
    São Tomé e Príncipe
    Slovenia
    Turchia
    Senegal
    Spagna
    Turkmenistan
    Seychelles
    Svalbard e Jan Mayen
    Uzbekistan
    Sierra Leone
    Svezia
    Vietnam
    Somalia
    Svizzera
    Yemen
    Sudafrica
    Ucraina
    Sudan
    Ungheria
    Sudan del Sud
    Tanzania
    Togo
    Tunisia
    Uganda
    Zambia
    Zimbabwe