Termékek közzététele
Single Stage Infrared Heater, Model UA

Single Stage Infrared Heater, Model UA

Heavy duty industrial/commercial infrared heater featuring the best overall performance in the industry. 40 MBH to 220 MBH rates available with 100% efficient reflector. Proven to be most efficient low-intensity heater available in North America with up to 65%* radiant factor. *Independent lab tested: EN416-2 Standard

  • 40,000 to 220,000 BTU/h
  • Natural Gas and LPG
  • Configurations of U and L, horizontal or 45°
  • Separate controls compartment – electronics out of air stream, the burner can run during servicing
  • Self-diagnostic ignition module
  • Parabolic aluminum reflectors - most efficient in the industry
  • Direct spark ignition
  • Vented or unvented
  • Operating status lights
  • 24v direct wire for the thermostat
  • Hinged service cover – easy to service
  • Jetstream burner – improved heat distribution, better combustion
  • Heavy duty couplings – no leaks, cannot be over tightened
  • Three-year warranty on all components
  • Five-year warranty on hot-rolled heat exchanger
  • Seven-year warranty on aluminized heat exchanger
  • Post-purge feature will extend warranty
Specifikáció
  • Low Intensity Single Stage Infrared Tube Heaters with minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. Assemblies shall be CSA approved low intensity heater to latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a positive pressure burner system, where exhaust gases and other products of combustion are not routed through the blower. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz.

    Burner head shall be chrome plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks with the burner operating. Reflector shall be 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within reflector. Reflectors with less than 10 surfaces will not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thickness aluminum sheet metal with two reflector support brackets for each 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss, and shall be standard equipment. Emitter Tube shall be 4 inch (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat treated type 1 aluminized steel tubing shall be required for all firing rates. Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length and be of heavy duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project.

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing minimum 65% radiant factor.
    • Professional Engineer Stamped Design, calculations and complete set of stamped drawings with alternate system.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).

Műszaki specifikáció
  • Egyedi azonosítóua
  • TermékcsaládSingle Stage Infrared Heaters
  • TermékcsoportLow Intensity - Series U
  • TípusObjektum (egy termék)
  • Megjelenés dátuma2021-02-16
  • Verziószám1
Kapcsolódó adatok
  • Elsődleges anyagAcél
  • Másodlagos anyagAlumínium
  • Tervezés helyeKanada
  • Gyártás helyeKanada
Besorolások
  • BIMobject kategóriaHVAC - Fűtőtestek
  • UNSPSC névTubular heaters
  • UNSPSC kód40101822
  • Uniclass 2015 kódPr_70_60_36_72
  • Uniclass 2015 leírásRadiant tube heaters
  • CSI MasterFormat 2014 kód23 55 23
  • CSI MasterFormat 2014 névGas-Fired Radiant Heaters
  • OmniClass szám23-33 15 17 13
  • OmniClass névFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II kódD30
  • CSI Uniformat II névHVAC

Termék elérhetősége

Észak-Amerika
Anguilla
Antigua és Barbuda
Aruba
Bahama-szigetek
Barbados
Belize
Bermuda
Brit Virgin-szigetek
Caribbean Netherlands
Costa Rica
Curaçao
Dominikai Közösség
Dominikai Köztársaság
Egyesült Államok
El Salvador
Grenada
Grönland
Guadeloupe
Guatemala
Haiti
Honduras
Jamaica
Kajmán-szigetek
Kanada
Kuba
Martinique
Mexikó
Montserrat
Nicaragua
Panamaváros
Puerto Rico
Saint Kitts és Nevis
Saint Lucia
Saint Pierre és Miquelon
Saint Vincent és a Grenadine-szigetek
Saint-Barthélemy
Saint-Martin
Sint Maarten
Trinidad és Tobago
Turks- és Caicos-szigetek
Virgin-szigetek