Publier vos produits
Bioretention Planters, GFRC
Bioretention Planters, GFRC
Bioretention Planters, GFRC
    Tournesol

    Bioretention Planters, GFRC

    Traduit par Google,

    GFRC - BÉTON LÉGER

    Nos jardinières de biorétention sont pré-construites et installées sur site pour collecter les eaux pluviales des canalisations/descentes pluviales. Les plantes et les médias filtrent l'eau, éliminent les solides organiques et inorganiques et libèrent lentement l'eau dans les égouts pluviaux, réduisant ainsi les débits de décharge de pointe.
    Nous proposons une gamme de tailles standard en aluminium et en GFRC – béton renforcé de fibres de verre, mais la plupart des projets de biorétention sont personnalisés.

    Spécification
    • Guide Specification

      Section 129300 Site Furnishings
      Section 129200 Interior Planters

      Tournesol Siteworks Fiberglass Planters and Planter Liners

      1.0 GENERAL

      1.1 WORK INCLUDED

      A. Provision of fiberglass planters and planter liners

      1.2 RELATED WORK

      A. Section 033000 Cast-in-Place concrete

      B. Section 061000 Rough Carpentry

      C. Section 062000 Finish Carpentry

      1.3 SUBMITTALS

      A. Product Data: Manufacturer's standard catalog cut sheets.

      B. Samples: As required for color selection or material thickness only.

      C. Shop Drawings: For custom applications, showing critical sizes and dimensions for

      installation and integration with other work.

      1.4 DELIVERY, STORAGE AND HANDLING

      A. Unwrap and inspect planters and planter liners after delivery for signs of damage during

      transit.

      B. Protect planters and planter liners from damage during storage and handling.

      C. Store planters and planter liners indoors if possible. Do not stand or walk on planters or

      planter liners.

      1.5 PROJECT CONDITIONS

      A. Contractor to provide adequate structural support for planter liner units. Unless

      otherwise specified, planters and liners should have continuous basal support.

      B. Protect units from damage by adjacent work.

      2.0 PRODUCTS

      2.1 ACCEPTABLE PRODUCTS/MANUFACTURERS

      A. Fiberglass Planters and planter liners, manufactured by Tournesol Siteworks LLC. 30955

      San Antonio St., Hayward, CA 94544 Tel: (800) 542-2282 FAX (510) 471-6243

      2.2 FIBERGLASS PLANTERS AND PLANTER LINERS

      A. Materials - All parts shall be constructed of glass fiber-reinforced polyester resin, using

      either the hand-layup or spray-layup methods.

      1. Glass fibers shall be PPG or equivalent. For hand layup fibers should be uniform

      chopped strand mat, minimum 3 oz. density. Smaller round containers will use one layer

      of mat (or spray equivalent), smaller squares and larger round containers must use two

      layers (or spray equivalent), larger square and rectangular containers must use min. 3

      layers (or spray equivalent).

      2. Polyester resin shall be compounded by a reputable manufacturer. All planters and

      planter liners will be fabricated of 100% resin – inorganic fillers will not be acceptable.

      3. Gel coating (where necessary) shall be of specified color. Metallic finishes will use

      atomized metal thoroughly blended with polyester resin, and applied over clean surfaces.

      4. Painted finishes will be made of polyurethane low VOC (less than 2.8 VOC) enamel

      with excellent corrosion and chemical resistance by PPG (AUE 280) or equivalent.

      B. Construction

      Architectural parts shall be fabricated by hand-layup, spray laminate, or resin transfer

      method using suitable molds to attain the desired surface finish. The finished reinforced

      plastic material shall be not less than 5/32" thick and thicker in those areas requiring

      additional structural strength.

      Where ribs or stiffeners are to be fastened to liner sections by spray laminating over

      premolded forms, the stiffeners or ribs shall be located and spray laminated into position so

      that the finished joint shall conform to performance specifications below.

      For vertical surface reinforcement, an inorganic honeycomb strengthening layer using

      double-veiled, bonded material shall be located and hand- or spray-laminted into position

      prior to the wall material setting. The entire honeycomb panel must be subject to pressure

      during curing to ensure proper bonding to wall. Honeycomb thickness will be minimum

      ¼”, or thicker as required for larger spans. Marine-grade plywood may be substituted for

      bottom panels to be penetrated with drainage or irrigation holes.

      Interior of planter or planter liner to be waterproofed with additional layer of black gel

      coating, additional waterproofing available as specified.

      C. Performance characteristics and capacities, finished product to yield the following

      minimum performances:

      Hardness, Barcol 50

      Tensile Strength, Ultimate 12500 psi

      Elongation at break 1.3%

      Modulus of Elasticity 1020 ksi

      Flexural Modulus 754 ksi

      Flexural Yield Strength 27600 psi

      Compressive Yield Strength 21800 psi

      Glass content, average 35%

      Vertical wall panels will not deform more than L/200 when loaded with 80 lbs/cu ft. soil

      mass. Similar performance with heavier media is available per specification.

      D. Finish: specified finish; factory finished.

      E. Sizes: Modular units fabricated to size by manufacturer as required to fill specified

      areas. Refer to catalog for standard sizes. Custom sizes as per approved shop drawings.

      F. Fire retardant requirement can be met with the addition of retardant chemicals to the

      resin. Additional information is available for this specification.

      2.3 PLANTER ACCESSORIES

      A. Field installed drainage/irrigation connection fitting. Thread-by-thread thermoplastic

      drainage adapter, ½”, ¾” and 1"NPT female thread available. Contractor to locate drainage

      hole, drill as necessary, and install fitting.

      B. Lifting hooks or stabilizer anchors, quantity, size, and capacity as specified.

      3.0 EXECUTION

      3.1 PREPARATION

      A. Prior to planter or planter liner fabrication, the contractor shall verify as-built dimensions

      of planter area or receptacles to ensure proper size, fit and quantity required.1

      B. Unless planters have drainage fittings as in 2.3.A, drainage holes to be located and made

      by contractor in the field to fit to drainage system.

      3.2 INSTALLATION

      A. Install planter liners to allow for easy removal if necessary.

      B. Provide continuous basal support.

      C. Install liners level to permit adequate drainage and irrigation.

      1 Field verification of actual planter receptacle size is frequently overlooked by the contractor, and can

      lead to delays and additional cost if neglected.

    Spécifications techniques
    • Réference unique.bioretention-planters-gfrc
    • Famille de produitsBioretention Planters
    • Groupe de produitsBioretention GFRC
    • TypeObjet (objet simple)
    • Date de publication2024-06-04
    • Numéro d'édition1
    En rapport
    • Matériel principalBéton
    • Conçu enÉtats-Unis
    • Fabriqué enÉtats-Unis
    Classification
    • BIMobject CatégorieJardins / Aménagements paysager - Paysage

    Disponibilité de la région

    L'Europe Amérique du Nord Asie Amérique du Sud
    Åland
    Anguilla
    Arménie
    Argentine
    Albanie
    Antigua-et-Barbuda
    Azerbaïdjan
    Bolivie
    Allemagne
    Aruba
    Bangladesh
    Brésil
    Andorre
    Bahamas
    Bhoutan
    Chili
    Autriche
    Barbade
    Brunéi Darussalam
    Colombie
    Belgique
    Belize
    Cambodge
    Équateur
    Biélorussie
    Bermudes
    Chine
    Guyana
    Bosnie-Herzégovine
    Canada
    Corée du Nord
    Guyane française
    Bulgarie
    Costa Rica
    Corée du Sud
    Îles Falkland (Malvinas)
    Chypre
    Cuba
    Géorgie
    Paraguay
    Croatie
    Curaçao
    Hong Kong
    Pérou
    Danemark
    Dominique
    Île Christmas
    Suriname
    Espagne
    El Salvador
    Îles Cocos (Keeling)
    Uruguay
    Estonie
    États-Unis
    Inde
    Venezuela
    Finlande
    Grenade
    Indonésie
    France
    Groenland
    Japon
    Gibraltar
    Guadeloupe
    Kazakhstan
    Grèce
    Guatemala
    Kirghizistan
    Guernesey
    Haïti
    Laos
    Hongrie
    Honduras
    Macao
    Île de Man
    Îles Caïmans
    Malaisie
    Îles Féroé
    Îles Turks et Caïques
    Maldives
    Irlande
    Îles Vierges britanniques
    Mongolie
    Islande
    Îles Vierges des États-Unis
    Myanmar (Birmanie)
    Italie
    Jamaïque
    Népal
    Jersey
    Martinique
    Ouzbékistan
    Lettonie
    Mexique
    Pakistan
    Liechtenstein
    Montserrat
    Philippines
    Lituanie
    Nicaragua
    Singapour
    Luxembourg
    Panama
    Sri Lanka
    Macédoine du Nord
    Pays-Bas caribéens
    Tadjikistan
    Malte
    Porto Rico
    Taïwan
    Moldavie
    Republique de Trinite et Tobago
    Territoire britannique de l'océan Indien
    Monaco
    République dominicaine
    Thaïlande
    Monténégro
    Saint-Barthélemy
    Turkménistan
    Norvège
    Saint-Kitts-et-Nevis
    Vietnam
    Pays-Bas
    Saint-Martin
    Pologne
    Saint-Martin
    Portugal
    Saint-Pierre-et-Miquelon
    République tchèque
    Saint-Vincent et les Grenadines
    Roumanie
    Sainte-Lucie
    Royaume-Uni
    Russie
    Saint-Marin
    Serbie
    Slovaquie
    Slovénie
    Suède
    Suisse
    Svalbard et Jan Mayen
    Ukraine
    Vatican