    4.5 sur 5 étoiles4.5(12 Avis)

    The Pressure Reducing Valve shall be a diaphragm actuated, pilot controlled valve. The main valve body shall be ductile iron ASTM A 536. The stem of the basic valve shall be guided top and bottom. The diaphragm shall not be used as a seating surface. All internal and external ferrous surfaces shall be coated with a high quality, fusion epoxy coating. The pilot control shall be field adjustable from 15 psi to 120 psi. The valve shall be certified to NSF/ANSI/CAN Standard 61. The Pressure Reducing Valve shall be a ZURN WILKINS Model ZW209.

    Compliance:

    • Massachusetts Approved
    • NSF61
    • NSF 372
    • AWWA C530

    Features:

    • Inlet and outlet pressure gauges, wye strainer, and isolation valves come standard and provide for quick and easy maintenance or repair
    • Reactive pilot assembly ensures constant downstream set pressure
    • 150 class flanged, 300 class flanged, grooved, and threaded end connections available for versatile installation
    • Globe, reduced port globe, and angle bodies available
    • Lead free

    Keywords: Boiler Rooms and Custodial Areas, Healthcare, Emergency and Public Entrance Areas, and Grounds, Boiler/Mechanical Rooms, Retail, Custodial Closets, Office, Commercial, Hospitality, Industrial, Janitorial Closets/Custodial Closets, Commercial Turf, Irrigation, Residential/Commercial Irrigation, School Systems, Educational Facilities, Gymnasium/Pool, Stadiums, Universities, Government Buildings, High Rise Buildings, Sports Complex/Recreational Center, Turf/Field/Track, Residential Multi-Family, Residential/Light Commercial, Recreational Facility, Correctional/Institutional, Architectural/Aesthetics, Clubhouse/Pool, Development, Civil, Transportation, Power Generation, Fire Protection, Distribution, Waterworks, Hydro-Electric Plant, Pump Stations, Water Treatment and Storage, Food Service, Industrial/Processing Plant, Automatic Control Valves, Lead-Free Products, Zurn Wilkins Water Control, Pressure Reducing Valves, Zurn Wilkins Automatic Control Valves, Zurn Wilkins Pressure Reducing Valves, Lead-Free Law Compliance, Low-Lead-IAPMORT, MasterSpec, NSF-ANSI, Retrofit and Replacement, Water Conservation, Zurn Wilkins,W209,209

    Spécification

    Spécifications techniques
    • Réference unique.zurn-zw209
    • Famille de produitsPressure Reducing Valves
    • Groupe de produitsAutomatic Control Valves
    • TypeObject (single object)
    • Date de publication2017-01-16
    • Numéro d'édition2
    • Hauteur (pouces)7.13
    • Largeur (pouces)5.63
    • Profondeur (pouces)7.25
    En rapport
    • Matériel principalDuctile Iron
    • Conçu enUnited States
    • Poids net (Lbs)22
    Classification
    • BIMobject CatégoriePlumbing - Valves
    • Classification IFCValve
    • Code Uniclass 2015Pr_65_54_95_66
    • Description de l'Uniclass 2015Pressure reducing valves
    • Code CSI MasterFormat 201440 05 67.36
    • Titre CSI MasterFormat 2014Pressure-Regulating Valves
    • Numéro OmniClass23-27 31 47