Building Materials - Paint, Varnishes & FinishesAdhesionQUALICOAT CLASS 2 ISO 2409 §6.3.4 Pass
ApplicationEletrostatic / Tribo
Chemical ResistanceSulphuric Kesternich (EN ISO 3231) | Resistance to mortar (ASTM D3260, EN12206-1, par.5.9) | Resistance to boiling water (Qualicoat method 1) | Condensation water test (EN ISO 6270-2)
ColourVisual to Standard /ΔΕ
Corrosion ResistanceAcetic acid salt spray (EN ISO 9227)
ExposureAccelerated Weathering test EN ISO 16474-2 (Qualicoat cycle) | Natural weathering 36 months Florida 5° South (ISO 2810)
Exposure RatingQUALICOAT CLASS 2
Exterior DurabilityQUALICOAT CLASS 2
Flame Spread IndexClassification : A2 - s1, d0 in accordance with the NF EN 13501-1:2018 standard.
FlexibilityDirect Impact (EN ISO 6272-1, EN ISO 6272-2, ASTM D2794) | Reverse Impact (EN ISO 6272-1, EN ISO 6272-2, ASTM D2794) | Bend Test (EN ISO 1519)
HardnessIndentation Buchholz (EN ISO 2815)
Smoke DevelopmentClassification : A2 - s1, d0 in accordance with the NF EN 13501-1:2018 standard.
Substrate MaterialAluminium, Steel | Galvanized Steel | Stainless Steel
Surface PreparationIn Accordance with NEOKEM regulatory guidelines
Total DFT60 Microns Minimum
EPD Data (Simplified) A1-A3Energy Consumption (A1-A3)69.374 MJ - 87.177 MJ
EPD Declaration UnitKilogram of Powder Coating
EPD Expiration Date2026-08-31
EPD Issue Date2021-09-01
EPD Registration NumberS-P-04000
Global Warming (A1-A3)2.289 kg - 3.867 kg
Non Renewable Resources Consumption (A1-A3)61.93 MJ - 78.585 MJ
Waste Production (A1-A3)0.042 kg - 0.045 kg
Water Consumption (A1-A3)0.016 m³ - 0.039 m³