Publique sus productos
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot

    O2D Fertile Foundation for light vehicle parking lot

    Traducido por Google,

    El material de base fértil O2D para estacionamiento de vehículos livianos se recomienda en el contexto del desarrollo de espacios de estacionamiento verdes permeables.

    Este material de cimentación, recomendado por O2D ENVIRONNEMENT, está compuesto por mezclas de firme triturado y materia orgánica. Las características técnicas de este material de cimentación fértil se han definido en conjunto con el pavimento permeable TTE®: rejillas TTE® para césped in situ (TTE MULTIDRAIN) o rejillas TTE® pre-césped (O2D GREEN).

    Composición recomendada del material de base fértil:

    • 15 cm de espesor: material de cimentación de suelo y piedra TP GREEN
    o 75% material triturado de granulometría 20/40 mm
    o 25% sustrato orgánico (tierra vegetal/arena lavada/compost) de granulometría 0/10 mm
    • 3 cm de espesor: LP GREEN lecho fértil
    o 60% material triturado de granulometría 4/6 mm
    o 20% tierra vegetal/mezcla franco de tamaño de partícula 0/10 mm
    o 20% arena de granulometría 0/4 mm

    Base / subbase preparada (-23 cm en relación al nivel 0):

    • La permeabilidad requerida debajo de este sistema de cimentación es tal que K > 10 -6 m/s
    • El nivel de carga requerido es tal que EV2 > 40 MPa (EV2/EV1 < 2)
    • Recomendamos la instalación de una membrana geotextil anticontaminante permeable

    Esta composición de material de base fértil asegura tanto la capacidad de carga como de drenaje, y proporciona los nutrientes necesarios para el enraizamiento efectivo de la hierba.

    Se recomienda ajustar el espesor de la subbase (por ejemplo, grava de drenaje triturada de 20/40 mm) y/o incorporar cualquier otra instalación, si la superficie natural del suelo no posee las propiedades de infiltración requeridas, o para la satisfacción de los requisitos de diseño del proyecto.

    El nivel de carga debe ser apropiado para la aplicación prevista.

    Aplicaciones:
    - Estacionamientos verdes permeables
    - Plazas de aparcamiento permeables con relleno combinado de pavimento/césped
    - Vías peatonales o ciclistas

    Especificaciones
    • Recommended deployment for the creation of a fertile foundation for green light vehicle parking spaces:

      - Preparation of base structure

               o  Mechanical or manual execution of excavation and backfill operations, up to the sides of the base structure: - 23 cm in relation to level 0
               o  Surface adjustment and levelling to an altimetric accuracy of +/- 2 cm/m
               o  Confirmation of a permeability coefficient K > 10-6 m/s
               o  Confirmation of the load-bearing capability of ground such that EV2 > 40 MPa, where EV2/EV1 < 2
               o  Clean-up of roadways employed

      - Installation of edging to the concrete foundation, the shoulder of which, at its highest point, is 8 cm below the levelled surface.

      - Installation of a permeable anti-contaminant geotextile membrane

      - Execution of a fertile draining foundation

               o  Adjustment, levelling and vibratory compaction of successive layers of an O2D® TP GREEN ready-to-use soil/stone mixture or equivalent:
                            - 75% crushed material of particle size 20/40 mm
                            - 25% organic substrate (topsoil/washed sand/compost) of particle size 0/10 mm
                    Finished thickness after rolling: 15 cm (or - 8 cm from the levelled edging surface).

               o  Levelling and compaction of O2D® LP GREEN ready-to-use bedding course or equivalent:
                            - 60% crushed material of particle size 4/6 mm
                            - 20% topsoil/loam mixture of particle size 0/10 mm
                            - 20% sand of particle size 0/4 mm
                    Finished thickness: 3 cm (or - 5 cm from the levelled edging surface).

      - Installation of O2D FYNET laying mesh

      - Installation of TTE® O2D GREEN pre-grassed grids, or installation of TTE® grids for grassing in situ.

    Especificaciones técnicas
    • Referenciafertile-foundation-parking-lot
    • Familia de productoComplete Systems
    • Grupo de productosGrassed parking lot for light vehicules
    • TipoObjeto (objeto simple)
    • Día de publicación2019-09-11
    • Número de edición1
    • Altura (mm)180
    Información relacionada
    • Material principalPiedra natural conglomerada
    • Material secundarioOrgánico
    • Diseñado enFrancia
    • Fabricado enFrancia
    Clasificación
    • Categoría BIMobjectMateriales de construcción - Adoquines, pavimentos exteriores
    • Clasificación IFC Floor
    • Nombre UNSPSCStone or tile flooring
    • Código UNSPSC30161706
    • Código Uniclass 2015Ss_30_14
    • Descripción Uniclass 2015Paving systems
    • CSI MasterFormat 2014 Code32 01 19
    • CSI MasterFormat 2014 TítuloRigid Paving Surface Treatment
    • Número OmniClass23-11 21 17
    • Título OmniClass Paving Blocks
    • CSI UniFormat II CódigoB1010
    • CSI UniFormat II TítuloFloor Construction

    Disponibilidad en regiones

    Europa Sudamerica Norteamérica Oceanía África
    Bélgica
    Guayana Francesa
    Guadalupe
    Nueva Caledonia
    Reunión
    Francia
    Martinica
    Wallis eta Futuna
    Luxemburgo
    San Pedro y Miquelón
    Suiza