Publish your products
TWG Ventilace facade - complete solution

TWG Ventilace facade - complete solution

Hedged TWG facades are facades with a rear ventilation room between thermal insulation and

Xterior Compact / Xterior Compact F or for uninsulated structures and wooden buildings between the load -bearing

Underground and Xterior Compact / Xterior Compact F. The rear ventilation room is due to supply air openings on the

Underside and exhaust air openings on the top of the wall or wall sections (e.g.

tung) connected to the outside air and thus enables constant air change.

Purchased behind ventilated facades (VHF) consist of:

1. Xterior Compact / Xterior Compact F

They serve the weather protection and facade design.

2. Hinting ventilation

The rear ventilation room is an area flows from the outside between the

Inside the clothing and the outside of the wall or thermal insulation. This serves the moisture

Protection of the layers behind it, the derivation of moisture loads from inside or outside as well as the

Management of the summer warming.

3. Substructure

Substructures for VHF can be made of metal, wood or fiber reinforced plastics and combinations

can be made from these materials.

4. Trot profile

Trot profiles are elements that mechanically combine the components of the substructure with each other.

5. Fastening point

Fastening points are points that the Xterior Compact / Xterior Compact F on the substructure mecha

Fasten niche by metal elements or by means of gluing.

6. Insulation material

Thermally insulating layer between anchorage and rear ventilation room; The thermal insulation

can- depending on the material- also fulfill fire and soundproofing functions.

7. Wall underground

The reason for anchoring is the load -bearing construction of the building. It serves to record the static

loads. The substructure is anchored in the structure.

Surface layers, e.g. B. plaster, coatings, are usually not sustainable.

Specification
  • Requirements for the Facadenko Ntrau

    Purchased behind ventilated facades (VHF) are mechanically connected to the structure and must at any time

    be stable. The following loads must be taken into account object -specific:

    - Own load

    - Wind loads (so -called and pressure)

    - and ice loads

    - shock loads

    - special loads (e.g. seismic loads, advertising boards)

    The proof of stability for the VHF system is, including all individually, in a testable form

    according to the state of the art and the respective European and/or national regulations accordingly

    provide. The proof of stability has in particular the static calculation of the substructure, which

    To contain clothing as well as the anchoring and connection elements.

    The own load results from the own weight of the clothing and substructure. Corresponding values

    can be removed from the technical data sheet.

    The wind loads have to be distinguished. The variables to be used in the calculation are

    Among other things, dependent on building geometry, the execution of the facade clothing and the building site.

    In traffic areas, special loads (impact, ball throw or similar) may have to be taken into account (closer distress

    de substructure etc.).

Technical specification
  • Unique ref.ventilace-facade-complete-solution
  • Product familyfacade
  • Product groupcomplete solution
  • TypeObject (single object)
  • Date of publishing2024-02-02
  • Edition number1
  • Height (mm)2070
  • Width (mm)2800
  • Depth (mm)8
Related
  • Material mainLaminated Paper
  • Material secondaryWood
  • Designed inGermany
  • Manufactured inGermany
  • Weight Net (Kg)85
Classification
  • BIMobject CategoryWalls - Cladding
  • IFC classificationCurtain Wall
  • ETIM CodeEG020350
  • ETIM NameBuilding - Facade cladding
  • UNSPSC nameSiding and exterior wall materials
  • UNSPSC code301518
  • Uniclass 2015 CodeSs_25_20
  • Uniclass 2015 DescriptionWall cladding systems
  • CSI MasterFormat 2014 Code07 42 23
  • CSI MasterFormat 2014 TitleWood Wall Panels
  • OmniClass Number23-13 33 19 11
  • OmniClass TitleCladding and Curtainwall Panels
  • CSI UniFormat II CodeB2010
  • CSI UniFormat II TitleExterior Walls

Region availability

Europe
Austria
Germany
Switzerland