Fire proofing and acoustic correction spray-on powder | FIREPLASTER® PROJISO
PROJISO

Fire proofing and acoustic correction spray-on powder | FIREPLASTER® PROJISO

What is Fireplaster® 270

Fireplaster 270® is a sprayable powder mixture used for fire protection and acoustic correction. The material consists of gypsum- vermiculite plaster and special additives.

What are the key features of Fireplaster® 270

Fireplaster® 270 is rot-proof, non-combustible and easy to work with. It can be stored for a maximum of 12 months as from the date of manufacture in unopened packaging. Fireplaster® 270 storage conditions: protect from frost, moisture, excessive heat and excessive radiant sunlight.
Fireplaster® 270 is packaged in 20-kg plastic bags.

Fireplaster® 270 areas of application

Fireplaster 270® coating is used for fire protection and acoustic correction.
Fireplaster 270® can be sprayed on concrete floors and structures, steel structures, concrete slabs with structural floor trays, double-skin cladding.

Fireplaster® 270 implementation techniques

Fireplaster®270 coating is sprayed on. Spraying is done with a pump/mixer.
This paste-like mixture is a mortar in powder format. The product is sprayed with a pump through a hose and a spray gun, and mixed with air.

The machine generally includes a feed hopper, a mixing chamber, a pump (important depending on the product to be sprayed), a hose to convey the spray mixture, and a spray gun that delivers the mixture.

A bonding agent that is suitable for the substrate must be applied before the coating is sprayed on.
Projiso Fixo B® is used for concrete.
Projiso Fixo M® is used for metal substrates.
Projiso Fixo M+® can be used on both difficult substrates.

The coating finish can be left rough with a surface grain or tinted with Sidairless®.

Specification
  • TECHNICAL CHARACTERISTICS

    coloreegg shell
    Aspectgranular
    volumic mass430kg/m3 ± 15%
    Consumption/m²from 3 to 3,5 Kg/m²/cm
    Reaction to fireA1
    pH7
    initial setting time24 hours at 20°C and 50% HR
    Grip methodBy hydraulic outlet
    Operating temperatureFrom 5 to 45°C
    Thermal conductivity0,095 W/m.k
    C.O.V.A+
    OthersFDES - CE marking
Technical specification
  • Unique ref.fireplaster
  • Product familyFire, Acoustics
  • Product groupInsulation
  • TypeObject (single object)
  • Date of publishing2023-09-04
  • Edition number1
Related
  • Material mainGypsum
  • Material secondaryPlaster
  • Designed inFrance
  • Manufactured inFrance
Classification
  • BIMobject CategoryBuilding Materials - Protective Coatings
  • IFC classificationCeiling
  • OmniClass Number23-13 25 19 15
  • OmniClass TitleThermal Insulation Coatings

Region availability

Europe Asia North America Africa South America Oceania
Åland Islands
Afghanistan
Anguilla
Algeria
Argentina
American Samoa
Albania
Armenia
Antigua and Barbuda
Angola
Bolivia
Australia
Andorra
Azerbaijan
Aruba
Benin
Brazil
Cook Islands
Austria
Bahrain
Barbados
Botswana
Chile
Federated States of Micronesia
Belarus
Bangladesh
Belize
Burkina Faso
Colombia
Fiji
Belgium
Bhutan
Bermuda
Burundi
Ecuador
French Polynesia
Bosnia and Herzegovina
British Indian Ocean Territory
British Virgin Islands
Cameroon
Falkland Islands (Islas Malvinas)
Guam
Bulgaria
Brunei
Canada
Cape Verde
French Guiana
Kiribati
Croatia
Cambodia
Caribbean Netherlands
Central African Republic
Guyana
Marshall Islands
Cyprus
China
Cayman Islands
Chad
Paraguay
Nauru
Czech Republic
Christmas Island
Collectivity of Saint Martin
Comoros
Peru
New Caledonia
Denmark
Cocos (Keeling) Islands
Costa Rica
Côte d'Ivoire
Suriname
New Zealand
Estonia
Georgia
Cuba
Democratic Republic of the Congo
Uruguay
Niue
Faroe Islands
Hong Kong
Curaçao
Djibouti
Venezuela
Norfolk Island
Finland
India
Dominica
Egypt
Northern Mariana Islands
France
Indonesia
Dominican Republic
Equatorial Guinea
Palau
Germany
Iran
El Salvador
Eritrea
Papua New Guinea
Gibraltar
Iraq
Greenland
Eswatini
Pitcairn Islands
Greece
Israel
Grenada
Ethiopia
Samoa
Guernsey
Japan
Guadeloupe
Gabon
Solomon Islands
Hungary
Jordan
Guatemala
Ghana
Timor-Leste
Iceland
Kazakhstan
Haiti
Guinea
Tokelau
Ireland
Kuwait
Honduras
Guinea-Bissau
Tonga
Isle of Man
Kyrgyzstan
Jamaica
Kenya
Tuvalu
Italy
Laos
Martinique
Lesotho
United States Minor Outlying Islands
Jersey
Lebanon
Mexico
Liberia
Vanuatu
Latvia
Macau
Montserrat
Libya
Wallis and Futuna
Liechtenstein
Malaysia
Nicaragua
Madagascar
Lithuania
Maldives
Panama
Malawi
Luxembourg
Mongolia
Puerto Rico
Mali
Malta
Myanmar (Burma)
Saint Kitts and Nevis
Mauritania
Moldova
Nepal
Saint Lucia
Mauritius
Monaco
North Korea
Saint Pierre and Miquelon
Mayotte
Montenegro
Oman
Saint Vincent and the Grenadines
Morocco
Netherlands
Pakistan
Saint-Barthélemy
Mozambique
North Macedonia
Palestine
Sint Maarten
Namibia
Norway
Philippines
The Bahamas
Niger
Poland
Qatar
Trinidad and Tobago
Nigeria
Portugal
Saudi Arabia
Turks and Caicos Islands
Republic of the Congo
Romania
Singapore
U.S. Virgin Islands
Reunion
Russia
South Korea
United States
Rwanda
San Marino
Sri Lanka
Saint Helena
Serbia
Syria
São Tomé and Príncipe
Slovakia
Taiwan
Senegal
Slovenia
Tajikistan
Seychelles
Spain
Thailand
Sierra Leone
Svalbard and Jan Mayen
Türkiye
Somalia
Sweden
Turkmenistan
South Africa
Switzerland
United Arab Emirates
South Sudan
Ukraine
Uzbekistan
Sudan
United Kingdom
Vietnam
Tanzania
Vatican City
Yemen
The Gambia
Togo
Tunisia
Uganda
Western Sahara
Zambia
Zimbabwe