Publish your products
nVent RAYCHEM 465 Fire Sprinkler Freeze Protection Controller
nVent

nVent RAYCHEM 465 Fire Sprinkler Freeze Protection Controller

The nVent RAYCHEM 465 is a c-UL-us Listed single point heat tracing controller designed for fire sprinkler/fire suppression systems. It includes a 5" inch color touch screen display for intuitive set up and programming right out of the box. The 465 controller may be used with line-sensing or ambient-sensing and Proportional Ambient-Sensing Control (PASC) modes. It measures temperatures with two 2 KOhm / 77°F (25°C), 2-wire Thermistors connected directly to the unit. The controller can also measure ground fault current to ensure system integrity. The controller includes ground fault current sensing and relaying equipment compliant with UL1053 standard. 

Specification
    • Supply voltage: 120/208/240/277 VAC, 50/60 Hz
    • Ambient operating temperature range: 32°F (0°C) to 105°F (40°C)
    • Maintain temperature setpoint:  32ºF (0ºC) to 105ºF (80ºC)
    • Internal power consumption: 9 W maximum
    • Output relay switching capacity: 24 A @ 120/208/240/277 +/-10% Vac; 50/60 Hz
    • Supervisory relay: Single pole single throw relay, volt-free; maximum switching capacity (resistive load only) 1 A/24 VDC, 1 A/24 VAC
    • Circuit breaker: 30 A maximum
    • Ground fault: 30 mA, complies with UL 1053 standard
    • Real time clock: Automatic daylight saving time and leap year correction
    • Clock accuracy: +/-10 minutes per year
    • Keylock: Password protection for parameter settings
    • USB port: For pre-setup in power off mode; for firmware upgrades




Technical specification
  • Unique ref.raychem-465-na
  • Product familynVent RAYCHEM North America
  • Product groupHeat Tracing - Pipe Freeze Protection; Flow Maintenance
  • TypeObject (single object)
  • Date of publishing2020-07-31
  • Edition number1
  • Height (inches)90
  • Width (inches)210
  • Depth (inches)85
Related
  • Material mainPolycarbonate
  • Designed inUnited States
  • Manufactured inGermany
Classification
  • BIMobject CategoryElectrical - Controls
  • IFC classificationController
  • ETIM CodeEC002063
  • ETIM NameAccessories for heating cables
  • UNSPSC nameFire sprinkler systems
  • UNSPSC code46191602
  • Uniclass 2015 CodeSs_55_30_96_85
  • Uniclass 2015 DescriptionSprinkler systems
  • CSI MasterFormat 2014 Code01 86 13
  • CSI MasterFormat 2014 TitleFire Suppression Performance Requirements
  • OmniClass Number23-31 00 00
  • OmniClass TitlePlumbing Specific Products and Equipment
  • CSI UniFormat II CodeD4090
  • CSI UniFormat II TitleOther Fire Protection Systems

Region availability

North America
Canada
United States