Publish your products
nVent PYROTENAX 2 Hour Fire Rated Single Power Conductors
nVent

nVent PYROTENAX 2 Hour Fire Rated Single Power Conductors

nVent PYROTENAX MI inorganic single conductor wiring cable solutions offer maximum ampacity with uncompromising performance of critical life safety circuits in the event of fire. Manufactured in North America with the industry's broadest product range, more 60 years of experience and with more thank 30 million feet of proven superior performance systems installed worldwide protecting occupants and first responders when they need it most. Lifetime Extended warranty available.

Typical fire-rated applications include wiring for fire pumps, emergency generators, firefighters’ elevators and smoke extraction fans.
Other applications include the retrofitting of electrical power feeders in commercial buildings when increased ampacity is required.

PYROTENAX two-hour fire-rated cable is dependable and versatile while providing the ultimate in safety and electrical circuit protection. Industry leading smallest footprint solution eliminates the need for additional conduit, concrete, sheetrock or vertical support boxes.  Zero smoke, zero flame spread and zero fuel contribution. Up to 80% space savings compared to conventional conduit and wire systems. 

Specification
  • Fire-RatED WIRING SYSTEMS (U.S.)
    MINERAL INSULATED (MI) CABLE

    This specification is dated 05/01/2022 and supersedes all previous versions.

    For detailed design information, please contact your local representative, our website at nVent.com/PRYOTENAX or nVent Thermal Technical Support 800-545-6258.

    General

      summary

      1. Furnish and install a complete UL Listed wiring system consisting of specified wiring cable, components, and accessories listed specifically for use with the system.

      ANSI / UL 2196 "Tests for Fire Resistive Cables”

      1. CSA C22.2#124

      ULC Fire Resistance Directory

      1. SUBMITTALS
        1. Provide product data for each cable type.
        2. Provide manufacturer’s Installation Instructions: Indicate application conditions and limitations of use stipulated by product testing agency specified under Regulatory Requirements.
      2. QUALIFICATIONS
        1. Supplier: Company specializing in manufacturing products specified in Section 16, Electrical.
        2. Supplier to have more than 30 years’ experience in manufacturing products in North America
        3. Supplier to have more than 30 million feet of product installed in North America
      3. REGULATORY REQUIREMENTS
        1. Conform to requirements of ANSI/NFPA 70.
        2. Conform to requirements of the Electrical Circuit Protective System listing in the UL Fire Resistance Directory.
        3. Furnish products listed by Underwriters Laboratories as suitable for the purpose specified.
      4. WARRANTYWhen warranties are required, verify with Owner's counsel that warranties stated in this article are not less than remedies available to Owner under prevailing local laws.For more detailed information on PYROTENAX's Product Warranty, see www.nvent.com/PYROTENAX.As a demonstration of quality, PYROTENAX, a brand of nVent offers a Lifetime extended warranty on all cable and components manufactured. Contractor (or PYROTENAX's field technician) must perform a system test as outlined in PYROTENAX's installation manual. The warranty being offered is required to be published on manufacturer's website.
        1. Manufacturer's Warranty: Provide Owner a product warranty for fire-rated wiring products described below.
          • Contractor must complete insulation resistance testing prior to Commissioning and maintain records of test results.
          • Warranty Period for Wiring Cable: Lifetime from date of Sale.
          • Warranty information must be published on manufacturer's website.
      5. PRODUCTS

      FIRE-RATED WIRING CABLE

      1. 2-hour fire-rated Mineral Insulated (nVent PYROTENAX MI) cables shall be acceptable.
      2. The wiring cable and splices and tees shall be listed in the UL Fire Resistance Directory.
      3. Mineral Insulated wiring Type MI cable shall have:
        1. Description: ANSI/NFPA 70, Type MI

      Conductor: solid high conductivity copper

      1. Insulation Voltage Rating: 600 volts

      Cable Temperature Rating: 90 degrees C

      1. Termination Temperature Rating: 90 degrees C

      Insulation Material: magnesium oxide

      1. Sheath Material: seamless soft-drawn copper

      Fire Rating: complete cable system shall have a 2-hour fire rating as listed and classified by Underwriters Laboratories, Inc. Contractor shall have a minimum of 10 years of experience in the installation of such systems.

      1. components
        1. Mineral Insulated cable components shall be cCSAus Certified.
        2. Mineral Insulated cable terminations shall consist of nVent:
          1. nVent PYROTENAX Model PyroPak (Installation Sheet H58872) or

      nVent PYROTENAX Model QuickTerm Termination (Installation Sheet H58264 or

      1. H58290) System Startup

      EXAMINATION

      1. Verify that the factory installed temporary end seals are intact.
      2. Verify that no moisture has entered cable insulation.

      End of Section

    Technical specification
    • Unique ref.nvent-thermal-008
    • Product familynVent PYROTENAX
    • Product groupFire Rated Wiring
    • TypeObject (single object)
    • Date of publishing2023-03-10
    • Edition number1
    Related
    • Material mainCopper
    • Material secondaryInsulation
    • Designed inUnited States
    • Manufactured inCanada
    Classification
    • BIMobject CategoryFire Products - Fire Protection
    • IFC classificationElectric Distribution
    • ETIM CodeEC001951
    • ETIM NameLow voltage cable system

    Region availability

    Europe Asia North America Africa South America Oceania
    Åland Islands
    Afghanistan
    Anguilla
    Algeria
    Argentina
    American Samoa
    Albania
    Armenia
    Antigua and Barbuda
    Angola
    Bolivia
    Australia
    Andorra
    Azerbaijan
    Aruba
    Benin
    Brazil
    Cook Islands
    Austria
    Bahrain
    Barbados
    Botswana
    Chile
    Federated States of Micronesia
    Belarus
    Bangladesh
    Belize
    Burkina Faso
    Colombia
    Fiji
    Belgium
    Bhutan
    Bermuda
    Burundi
    Ecuador
    French Polynesia
    Bosnia and Herzegovina
    British Indian Ocean Territory
    British Virgin Islands
    Cameroon
    Falkland Islands (Islas Malvinas)
    Guam
    Bulgaria
    Brunei
    Canada
    Cape Verde
    French Guiana
    Kiribati
    Croatia
    Cambodia
    Caribbean Netherlands
    Central African Republic
    Guyana
    Marshall Islands
    Cyprus
    China
    Cayman Islands
    Chad
    Paraguay
    Nauru
    Czech Republic
    Christmas Island
    Collectivity of Saint Martin
    Comoros
    Peru
    New Caledonia
    Denmark
    Cocos (Keeling) Islands
    Costa Rica
    Côte d'Ivoire
    Suriname
    New Zealand
    Estonia
    Georgia
    Cuba
    Democratic Republic of the Congo
    Uruguay
    Niue
    Faroe Islands
    Hong Kong
    Curaçao
    Djibouti
    Venezuela
    Norfolk Island
    Finland
    India
    Dominica
    Egypt
    Northern Mariana Islands
    France
    Indonesia
    Dominican Republic
    Equatorial Guinea
    Palau
    Germany
    Iran
    El Salvador
    Eritrea
    Papua New Guinea
    Gibraltar
    Iraq
    Greenland
    Eswatini
    Pitcairn Islands
    Greece
    Israel
    Grenada
    Ethiopia
    Samoa
    Guernsey
    Japan
    Guadeloupe
    Gabon
    Solomon Islands
    Hungary
    Jordan
    Guatemala
    Ghana
    Timor-Leste
    Iceland
    Kazakhstan
    Haiti
    Guinea
    Tokelau
    Ireland
    Kuwait
    Honduras
    Guinea-Bissau
    Tonga
    Isle of Man
    Kyrgyzstan
    Jamaica
    Kenya
    Tuvalu
    Italy
    Laos
    Martinique
    Lesotho
    United States Minor Outlying Islands
    Jersey
    Lebanon
    Mexico
    Liberia
    Vanuatu
    Latvia
    Macau
    Montserrat
    Libya
    Wallis and Futuna
    Liechtenstein
    Malaysia
    Nicaragua
    Madagascar
    Lithuania
    Maldives
    Panama
    Malawi
    Luxembourg
    Mongolia
    Puerto Rico
    Mali
    Malta
    Myanmar (Burma)
    Saint Kitts and Nevis
    Mauritania
    Moldova
    Nepal
    Saint Lucia
    Mauritius
    Monaco
    North Korea
    Saint Pierre and Miquelon
    Mayotte
    Montenegro
    Oman
    Saint Vincent and the Grenadines
    Morocco
    Netherlands
    Pakistan
    Saint-Barthélemy
    Mozambique
    North Macedonia
    Palestine
    Sint Maarten
    Namibia
    Norway
    Philippines
    The Bahamas
    Niger
    Poland
    Qatar
    Trinidad and Tobago
    Nigeria
    Portugal
    Saudi Arabia
    Turks and Caicos Islands
    Republic of the Congo
    Romania
    Singapore
    U.S. Virgin Islands
    Reunion
    Russia
    South Korea
    United States
    Rwanda
    San Marino
    Sri Lanka
    Saint Helena
    Serbia
    Syria
    São Tomé and Príncipe
    Slovakia
    Taiwan
    Senegal
    Slovenia
    Tajikistan
    Seychelles
    Spain
    Thailand
    Sierra Leone
    Svalbard and Jan Mayen
    Türkiye
    Somalia
    Sweden
    Turkmenistan
    South Africa
    Switzerland
    United Arab Emirates
    South Sudan
    Ukraine
    Uzbekistan
    Sudan
    United Kingdom
    Vietnam
    Tanzania
    Vatican City
    Yemen
    The Gambia
    Togo
    Tunisia
    Uganda
    Western Sahara
    Zambia
    Zimbabwe