Publish your products
UNIMIX / UNIMIX-C
IVAR

UNIMIX / UNIMIX-C

UNIMIX is a regulation unit designed to deliver water from a high temperature generator to the most suitable temperature for distribution in radiant circuits. All essential functions are achieved by just two components: mixing, boosting, drain/filling, air purge, shutoff, temperature monitoring and safety shutdown. Mixing is performed in a 3-way valve controllable from a fixed point or using climate compensation. Management of the radiant system is completed with distribution manifolds and relative accessories. It is also possible to divert a direct branch upline of the mixer thanks to a special set of manifolds, which can be selected either as simple versions or with shutoff valves. All UNIMIX components are available with pre-formed insulation casing, which makes the system suitable for applications in heating or cooling.

UNIMIX•C is a mixing system that, thanks to attentive simplification, has been developed to become a compact version of UNIMIX without losing its functional and performance features. All UNIMIX C components are available with pre-formed insulation casing, which makes the system suitable for heating or cooling applications.

Power (*): approx. 15 kW.
*Boiler temperature 60 °C; flow temperature with radiant system 40 °C with temperature variation of 7 °C; 8-way distribution manifolds

Specification
  • Mixing and pump units for radiant systems UNIMIX/UNIMIC-C modular with:

    • UM 01 – UM 01D/S: regulation unit UNIMIX with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermomanometer 0÷120 °C 0÷6 bar for mixed water, thermometers 0÷80 °C for delivery and return waters, probe pocket for mixed water, shut-off ball valves G 1” secondary side and automatic air vent valve. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar.
    • UMC 01 – UMC 01D/S: regulation unit UNIMIX-C with/without pump complete with 3-way mixing valve with headwork for thermostatic control, secondary by-pass with double micrometric adjustment and position memory, primary by-pass for recirculation, thermometer 0÷80 °C for mixed water and probe pocket for mixed water. Available with or without straight or angled shut-off ball valves G 3/4”F on primary side. Available with or without 3-speed standard pump WILO3F centre distance 130 mm or variable-speed electronic pump WILO4F centre distance 130 mm. Body made of nickel-plated CB753S brass; gaskets and O-rings made of peroxide-cured EPDM; other parts made of CW617N brass. Max operating temperature 100 °C. Max operating pressure 10 bar. Max differential pressure at mixing valve ends 250 mbar.
    • AUM 03: expanded polypropylene insulating cover.
    • T 5011 U: thermostatic head with incorporated control and immersion remote sensor. Range 30÷55 °C o 25÷50 °C. Cable lengh 2 m.
    • RV 01: axial servomotor M30x1.5. 3-point adjustment 230 V AC or proportional 0-10 V 24 V AC with display.
    • AUM 01 - AUM 11 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and plain manifolds with 3 outlets (EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1” primary side.
    • AUM 02 - AUM 12 D/S: high-temperature kit for UNIMIX/UNIMIX-C with primary side connections G 1” and manifolds with 3 outlets (delivery: double micrometric adjustment lockshield; return: headwork for thermostatic control with protection cap; EUROK outlets). Complete with fill/drain valve and differential pressure by-pass valve 0.2÷0.6 bar. Available with or without straight or angled shut-off ball valves G 1”F on primary side.
    • AC 613 FU: fixed setting 60 °C safety thermostat pre-wired.


Technical specification
  • Unique ref.UNIMIX_UNIMIX-C
  • Product familyRadiant systems
  • Product groupMixing and relaunch group for radiant systems UNIMIX / UNIMIX-C
  • TypeObject (single object)
  • Date of publishing2019-08-06
  • Edition number1
Related
  • Material mainBrass
  • Designed inItaly
  • Manufactured inItaly
Classification
  • BIMobject CategoryPlumbing - Other Plumbing
  • IFC classificationValve
  • UNSPSC nameValves
  • UNSPSC code401416
  • Uniclass 2015 CodeSs_60
  • Uniclass 2015 DescriptionHeating, cooling and refrigeration systems
  • CSI MasterFormat 2014 Code23 00 00
  • CSI MasterFormat 2014 TitleHeating, Ventilating, and Air Conditioning (HVAC)
  • OmniClass Number23-27 31 00
  • OmniClass TitleValves
  • CSI UniFormat II CodeD30
  • CSI UniFormat II TitleHVAC

Region availability

Europe Asia North America Africa South America Oceania
Åland Islands
Afghanistan
Anguilla
Algeria
Argentina
American Samoa
Albania
Armenia
Antigua and Barbuda
Angola
Bolivia
Australia
Andorra
Azerbaijan
Aruba
Benin
Brazil
Cook Islands
Austria
Bahrain
Barbados
Botswana
Chile
Federated States of Micronesia
Belarus
Bangladesh
Belize
Burkina Faso
Colombia
Fiji
Belgium
Bhutan
Bermuda
Burundi
Ecuador
French Polynesia
Bosnia and Herzegovina
British Indian Ocean Territory
British Virgin Islands
Cameroon
Falkland Islands (Islas Malvinas)
Guam
Bulgaria
Brunei
Canada
Cape Verde
French Guiana
Kiribati
Croatia
Cambodia
Caribbean Netherlands
Central African Republic
Guyana
Marshall Islands
Cyprus
China
Cayman Islands
Chad
Paraguay
Nauru
Czech Republic
Christmas Island
Collectivity of Saint Martin
Comoros
Peru
New Caledonia
Denmark
Cocos (Keeling) Islands
Costa Rica
Côte d'Ivoire
Suriname
New Zealand
Estonia
Georgia
Cuba
Democratic Republic of the Congo
Uruguay
Niue
Faroe Islands
Hong Kong
Curaçao
Djibouti
Venezuela
Norfolk Island
Finland
India
Dominica
Egypt
Northern Mariana Islands
France
Indonesia
Dominican Republic
Equatorial Guinea
Palau
Germany
Iran
El Salvador
Eritrea
Papua New Guinea
Gibraltar
Iraq
Greenland
Eswatini
Pitcairn Islands
Greece
Israel
Grenada
Ethiopia
Samoa
Guernsey
Japan
Guadeloupe
Gabon
Solomon Islands
Hungary
Jordan
Guatemala
Ghana
Timor-Leste
Iceland
Kazakhstan
Haiti
Guinea
Tokelau
Ireland
Kuwait
Honduras
Guinea-Bissau
Tonga
Isle of Man
Kyrgyzstan
Jamaica
Kenya
Tuvalu
Italy
Laos
Martinique
Lesotho
United States Minor Outlying Islands
Jersey
Lebanon
Mexico
Liberia
Vanuatu
Latvia
Macau
Montserrat
Libya
Wallis and Futuna
Liechtenstein
Malaysia
Nicaragua
Madagascar
Lithuania
Maldives
Panama
Malawi
Luxembourg
Mongolia
Puerto Rico
Mali
Malta
Myanmar (Burma)
Saint Kitts and Nevis
Mauritania
Moldova
Nepal
Saint Lucia
Mauritius
Monaco
North Korea
Saint Pierre and Miquelon
Mayotte
Montenegro
Oman
Saint Vincent and the Grenadines
Morocco
Netherlands
Pakistan
Saint-Barthélemy
Mozambique
North Macedonia
Palestine
Sint Maarten
Namibia
Norway
Philippines
The Bahamas
Niger
Poland
Qatar
Trinidad and Tobago
Nigeria
Portugal
Saudi Arabia
Turks and Caicos Islands
Republic of the Congo
Romania
Singapore
U.S. Virgin Islands
Reunion
Russia
South Korea
United States
Rwanda
San Marino
Sri Lanka
Saint Helena
Serbia
Syria
São Tomé and Príncipe
Slovakia
Taiwan
Senegal
Slovenia
Tajikistan
Seychelles
Spain
Thailand
Sierra Leone
Svalbard and Jan Mayen
Türkiye
Somalia
Sweden
Turkmenistan
South Africa
Switzerland
United Arab Emirates
South Sudan
Ukraine
Uzbekistan
Sudan
United Kingdom
Vietnam
Tanzania
Vatican City
Yemen
The Gambia
Togo
Tunisia
Uganda
Western Sahara
Zambia
Zimbabwe