Publish your products
FIXED SMOKE CURTAINS

FIXED SMOKE CURTAINS

Smoke curtains GSF KDS GLOBAL SYSTEM are intended to be used in buildings as barriers dividing space into smoke compartments. Their primary functions include: 

  • creating smoke compartments by containing and limiting the movement of smoke,
  • redirecting the movement of smoke,
  • preventing and delaying any influx of smoke into other areas or into air gaps.

Due to their design, smoke curtains can be combined modularly, allow to create security measures of unlimited dimensions. The curtains are suitable for a wide variety of applications in both public and commercial buildings.

Specification
  • TYPES OF SMOKE CURTAINS

    Classified by operating principle

    • GSF KDS Smoke Curtains – fixed
    • GSF KDR Smoke Curtains – mobile

    Classifed by fire resistance class

    • D600160
    • D600181
    • DH60
    • DH133

    Types of GSF KDR Mobile Smoke Curtains in terms of their operating principle

    • ASB1 The curtain descends as a result of activation or power outage, at a speed range of 0,06 – 0,30 m/s, no lower than 2,5 meters from the floor
    • ASB3 The curtain descends as a result of activation or power outage, at a speed range of 0,06 – 0,15 m/s, no lower than 2,5 meters from the floor
    • ASB2 The curtain descends as a result of activation at a speed range of 0,06 – 0,30 m/s, no lower than 2,5 meters from the floor
    • ASB4 The curtain descends as a result of activation at a speed range of 0,06 – 0,15 m/s, no lower than 2,5 meters from the floor

    SMOKE CURTAIN DESIGNGSF KDS FIXED SMOKE CURTAIN

    Fixed smoke curtain consists of

    • Curtain - made of fire-resistant material
    • Mount
    • Bottom bar

    GSF KDR AUTOMATIC SMOKE CURTAIN

    The curtain is rolled up around a shaft and maintained in this position by an electric motor. The curtain is released in the event of fire. The curtain is controlled by means of a central control panel.
    The mobile smoke curtain consists of:

    • Curtain - made of fire-resistant material
    • Shaft
    • Shaft box
    • Bottom bar
    • Curtain motor
Technical specification
  • Unique ref.smoke-curtains-fixed
  • TypeObject (single object)
  • Date of publishing2022-07-05
  • Edition number1
  • Height (mm)4550
Related
  • Designed inPoland
  • Manufactured inPoland
Classification
  • BIMobject CategoryFire Products - Smoke Ventilation
  • IFC classificationBuilding Element

Region availability

Europe Asia
Albania
Türkiye
Austria
Belarus
Belgium
Bosnia and Herzegovina
Bulgaria
Croatia
Cyprus
Czech Republic
Denmark
Estonia
Finland
France
Germany
Greece
Hungary
Ireland
Italy
Latvia
Lithuania
Moldova
Montenegro
Netherlands
North Macedonia
Norway
Poland
Portugal
Romania
Serbia
Slovakia
Slovenia
Spain
Sweden
Switzerland
Ukraine
United Kingdom