Publish your products
FOAMGLAS® BOARD T4+-200x600x1200
FOAMGLAS®

FOAMGLAS® BOARD T4+-200x600x1200

Suitable for a wide range of building envelope applications - floors, flat roofs, and roofs with a metal standing seam covering - FOAMGLAS® T4+ offers a thermal conductivity of 0.041 W/(m·K) and a UDL compressive strength of 600 kPa. Compressive strength requirements for any application should always be confirmed with a structural engineer to ensure the correct product specification.

Our cellular glass insulation boards measure 1200x600mm, and have a glass fleece facing, to aid adhesion and bonding. Boards are used throughout the entire internal and external building envelope, and are particularly useful upon profiled metal roof decks. The board insulation core comprises of cellular glass and so meets Euroclass A1 standards, only the thin fleece facing adds a combustible element, resulting in the overall board product being rated as E. The boards are popular for larger areas and faster installation.

Specification
    • Applications = Floors (incl. below ground structures) | Façades (cavity wall insulation, f.i. between 2 concrete shells) | Interior and exterior walls above and below ground | Interior and exterior soffits
    • Bending Strength =≥ 450 kPa
    • Capillarity = Zero
    • Compressive Stress = 633 kPa
    • Compressive Creep = CC(1.5/1/50) 225
    • Compressive Strength = ≥ 600 kPa
    • Flexural Modulus = 700 MN/m2
    • Forms of Delivery = Packaged in units of 2 to 14 boards per thickness.
    • Hygroscopicity = Zero
    • Length = 1200mm, ±5mm tolerance
    • Melting Point = >1000°C
    • Point Load = ≤ 1.5 mm
    • Reaction to Fire = Euroclass E (Core is Euroclass A1)
    • Service Temperature = -265°C to +430°C
    • Specific Heat = 1000 J/(kg·K)
    • Tensile Strength = ≥ 150 kPa
    • Thermal Conductivity (λD) = ≤ 0.041 W/(m·K
    • Thermal Diffusivity = 4.2 x 10-7 m2/sec
    • Thermal Expansion Coefficient = 9 x 10-6 K-1
    • Thermal Resistance (RD) = 4.85 m2K/W
    • Thickness = 200mm, ±2mm tolerance
    • Water Vapour Resistance = μ = ∞
    • Width = 600mm, ±2mm tolerance
Technical specification
  • Unique ref.FOAMGLAS_BOARD_T4-200x600x1200
  • Product familyBoard
  • Product groupT4+
  • TypeBuilding Material
  • Date of publishing2023-12-22
  • Edition number1
  • Height (mm)1200
  • Width (mm)600
  • Depth (mm)200
Related
  • Material mainCellular glass
Classification
  • BIMobject CategoryBuilding Materials - Insulation
  • ETIM CodeEC000406
  • ETIM NameThermal insulation
  • Uniclass 2015 CodePr_25_71_52_13
  • Uniclass 2015 DescriptionCellular glass insulation boards
  • CSI MasterFormat 2014 Code07 21 00
  • CSI MasterFormat 2014 TitleThermal Insulation
  • OmniClass Number23-13 25 19
  • OmniClass TitleThermal Insulation 

Region availability

Europe
Austria
Belgium
France
Germany
Italy
Netherlands
Sweden
Switzerland
United Kingdom